Deep neural networks have led to significant advancements in microscopy image generation and analysis. In single-molecule localization based super-resolution microscopy, neural networks are capable of predicting fluorophore positions from high-density emitter data, thus reducing acquisition time, and increasing imaging throughput. However, neural network-based solutions in localization microscopy require intensive human intervention and computation expertise to address the compromise between model performance and its generalization. For example, researchers manually tune parameters to generate training images that are similar to their experimental data; thus, for every change in the experimental conditions, a new training set should be manually tuned, and a new model should be trained. Here, we introduce AutoDS and AutoDS3D, two software programs for reconstruction of single-molecule super-resolution microscopy data that are based on Deep-STORM and DeepSTORM3D, that significantly reduce human intervention from the analysis process by automatically extracting the experimental parameters from the imaging raw data. In the 2D case, AutoDS selects the optimal model for the analysis out of a set of pre-trained models, hence, completely removing user supervision from the process. In the 3D case, we improve the computation efficiency of DeepSTORM3D and integrate the lengthy workflow into a graphic user interface that enables image reconstruction with a single click. Ultimately, we demonstrate superior performance of both pipelines compared to Deep-STORM and DeepSTORM3D for single-molecule imaging data of complex biological samples, while significantly reducing the manual labor and computation time.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12080944 | PMC |
http://dx.doi.org/10.1101/2025.04.13.648574 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFBMC Oral Health
September 2025
Oral and Maxillofacial Radiology Department, Cairo university, Cairo, Egypt.
Aim: The purpose of this study was to assess the accuracy of a customized deep learning model based on CNN and U-Net for detecting and segmenting the second mesiobuccal canal (MB2) of maxillary first molar teeth on cone beam computed tomography (CBCT) scans.
Methodology: CBCT scans of 37 patients were imported into 3D slicer software to crop and segment the canals of the mesiobuccal (MB) root of the maxillary first molar. The annotated data were divided into two groups: 80% for training and validation and 20% for testing.
Eur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.