A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of safety and stability after intraocular lens implantation using a novel material-crosslinked polyisobutylene: A preliminary study. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: To evaluate the safety and stability of an intraocular lens(IOL) made of crosslinked polyisobutylene (xPIB), a novel biomaterial for new-generation foldable IOL.

Setting: Eye Hospital of Wenzhou Medical University, Hangzhou, Zhejiang Province, China.

Design: Prospective observational study.

Methods: This was a prospective, parallel-controlled, randomised clinical study. Participants were randomly enrolled in a 1:1 ratio and underwent one-eye cataract removal with either xPIB or Acrysof (control) IOL implantation. The follow-up schedule was 1 day, 1 week, 1, 3, and 6 months, and 1 year after implantation. Various ocular biometric parameters were recorded and compared between the two groups.

Results: Precisely 38 (19 per group) participants were included in this study. All surgeries were performed successfully. The xPIB IOL showed less decentration than the Acrysof IOL [0.16 (0.08,0.21) vs. 0.18 (0.12,0.21) mm] 1 week after surgery (P=0.032). The anterior capsule opening area decreased during the trial, with more shrinkage in the xPIB than in the Acrysof IOL (P<0.05 at all-time points). The anterior capsule contraction negatively correlated with the changes in postoperative aqueous depth from 1 week to 6 months (r=-0.671, P=0.002) and was uncorrelated with the changes in spherical equivalent at all-time points (P>0.05). The differences in other ocular parameters were not statistically significant between the two groups (P<0.05).

Conclusions: The new xPIB IOL exhibited excellent in-the-bag stability and visual rehabilitation after cataract removal. Although the incidence was higher, the anterior capsule contraction in the xPIB group was not clinically significant and did not negatively impact vision.

Download full-text PDF

Source
http://dx.doi.org/10.1097/j.jcrs.0000000000001685DOI Listing

Publication Analysis

Top Keywords

safety stability
8
stability intraocular
8
xpib acrysof
8
acrysof iol
8
evaluation safety
4
intraocular lens
4
lens implantation
4
implantation novel
4
novel material-crosslinked
4
material-crosslinked polyisobutylene
4

Similar Publications