Background: Evaluation studies on active microprocessor-controlled knees (AMPK) in individuals with unilateral transfemoral amputation (TFA) are lacking in the literature. Furthermore, research on user accommodation to AMPK remains to be investigated. Hence, this study aims to conduct a comparison between an AMPK and individual's current prosthesis and assess the accommodation to using an AMPK during daily activities over a 5-week period on functional performance tests.
Methods: Participants with TFA completed a protocol comprising L-test, slope walking, level walking (2MWT) and dual-task level walking (dual-2MWT) once a week with their current prosthesis and the AMPK. The outcomes of interest were the distance covered during the 2MWT and dual-2MWT, time required to perform the L-test, accuracy of the serial subtractions during the dual-2MWT, heart rate (HR), rating of perceived exertion, fatigue, comfort and perceived workload. Generalised least-squared models were built to investigate differences in prosthetic conditions over time. Pearson correlations were calculated to determine associations between the performance and subjective outcomes. The level of significance was set at 0.05.
Results: Seven participants (age = 53 years ± 14 years) completed the study. Over time, the AMPK participants took longer to complete the L-test than their current prosthesis (p < 0.001). They reported higher fatigue (p = 0.033), lower comfort (p = 0.010), and higher perceived exertion with the AMPK (p = 0.048). Slope walking showed no significant walking speed or HR differences except higher HR with the AMPK in session 3 (p = 0.032). Dual-task level walking demonstrated lower walking speed with the AMPK (p = 0.035) and more responses to serial subtractions in sessions two (p = 0.043) and four (p = 0.023). No other differences between conditions were found on one of the functional tests. Weak associations (|r|= 0-0.5) were observed between performance and subjective measures.
Conclusion: Using the AMPK highlights initial challenges in task completion times and subjective comfort and fatigue levels. Our findings indicate that five one-hour sessions are insufficient for achieving user accommodation, and underscore the need for further research with a larger sample, continued prosthetic use and user accommodation to enhance prosthetic functioning and user experiences.
Trial Registration: NCT05407545.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12057274 | PMC |
http://dx.doi.org/10.1186/s12984-025-01637-5 | DOI Listing |
J Prosthet Dent
September 2025
Full Professor, School of Mechanical Engineering, Universidad Industrial de Santander, Bucaramanga, Colombia. Electronic address:
Statement Of Problem: Although custom temporomandibular joint (TMJ) prostheses manufactured via computer-aided design and manufacturing (CAD-CAM) and produced through 3-dimensional (3D) printing or computer numerical control (CNC) allow for sagittal curvature adjustments in the glenoid fossa, their design remains unregulated by the Food and Drug Administration. Consequently, the geometry is determined largely by the engineer's discretion, with limited biomechanical evidence to guide these decisions. The lack of validation regarding how sagittal curvature influences joint stress distribution under various anatomical and functional conditions represents a gap in current knowledge that warrants investigation.
View Article and Find Full Text PDFCardiol Rev
September 2025
Departments of Cardiology and Medicine, Westchester Medical Center and New York Medical College, Valhalla, NY.
Patients with atrial fibrillation, venous thrombosis, and mechanical heart valve (MHV) regularly undergo procedures on a daily basis, for which they require bridging anticoagulation, but this poses significant challenges. Bridging anticoagulation involves temporary interruption of long-term anticoagulation therapy for procedures and continued overlap with short-acting anticoagulants during perioperative period. Heparin-based agents are often used for overlapping in perioperative period to reduce the risk of thromboembolism, but the evidence for benefit particularly in patients with MHV remains limited.
View Article and Find Full Text PDFKardiologiia
September 2025
West China Hospital of Sichuan University, Department of Cardiovascular Surgery, Sichuan University.
A middle-aged female presenting with progressive heart failure was admitted to the emergency department. She had a history of mitral and aortic valve replacement and a reoperation involving the Konno procedure. Echocardiography suggested a possible paraprosthetic leakage, which was confirmed during surgery.
View Article and Find Full Text PDFRev Recent Clin Trials
September 2025
Department of Radiation Oncology, University Hospital of Iraklion, 71110, Iraklion, Greece.
Introduction: Radiotherapy (RT) is an integral component of various multidisciplinary treatment approaches for pelvic malignancies, used both in the radical and adjuvant setting. Despite the improvement of radiotherapy modalities, pelvic radiotherapy often induces permanent erectile dysfunction (ED). However, post-treatment ED receives little medical attention, since patient follow-up focuses mainly on cancer recurrence surveillance.
View Article and Find Full Text PDFJ Mol Histol
September 2025
Department of Urology, Yantai Yuhuangding Hospital, Qingdao University, No. 20 East Yuhuangding Road, Yantai, 264000, Shandong, China.
The stress urinary incontinence (SUI) is a difficulty in urology and current sub-urethral sling treatments are associated with inflamation and recurrence. In this study, we developed a novel tissue-engineered sling with myogenic induced adiposederived stem cells (MI-ADSCs) sheets induced by 5-Aza and combined with electrospun scaffolds of silk fibroin and poly(lactide-co-glycolide) (SF/PLGA) for the treatment of stress urinary incontinence. MI-ADSCs increased α-SMA, MyoD and Desmin the mRNA and protein expression.
View Article and Find Full Text PDF