Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Elevated intraocular pressure (IOP) is a major risk factor for blindness in glaucoma patients, highlighting the critical need for continuous IOP monitoring. While traditional transpalpebral tonometers (TTs) circumvent corneal contact by adopting Goldmann applanation principles through impulsive corneal flattening forces, their measurement accuracy is inherently compromised by eyelid-induced cushion effects. In contrast, parallel-plate capacitive sensors employ constant compressive loading upon the eyelid, achieving palpebral compaction to mitigate the cushion effects. More recently, ion-pump-based capacitive sensors have emerged as promising alternatives, particularly due to their enhanced sensitivity. Nevertheless, these sensors exhibit sharp sensitivity deterioration at extended measurement ranges (0-10 kPa). This operational constraint originates from the strong hydrogen bond energies (between confining matrices and ions) and rigid block copolymer matrices' steric hindrance. To address these limitations, we developed a transpalpebral tonometer featuring low-energy-barrier ion pumps, incorporating (3-aminopropyl)triethoxysilane (APTES)-silanized liquid metal nanoparticles (LM NPs) as confining matrices and an ionic liquid as an ion donor. The low-energy barrier arises from (1) weaker hydrogen bonds between the N-H of APTES and the F of the ionic liquid and (2) reduced crystallinity in the elastomeric matrices induced by LM NPs. Our sensor achieves a sensitivity of 24.88 kPa with maintained linearity over 0-85 kPa. In vivo animal trials over 120 min validated its continuous IOP monitoring capability, reliably detecting elevated IOP states and demonstrating clinical potential for glaucoma management.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12097244PMC
http://dx.doi.org/10.1021/acsnano.5c02762DOI Listing

Publication Analysis

Top Keywords

intraocular pressure
8
low-energy-barrier ion
8
continuous iop
8
iop monitoring
8
cushion effects
8
capacitive sensors
8
confining matrices
8
ionic liquid
8
reproducible transpalpebral
4
transpalpebral intraocular
4

Similar Publications

Purpose: To investigate hand function and eye drop instillation success in adults with and without glaucoma.

Design: Cross-sectional pilot study.

Subjects: Adults aged ≥ 65 years with glaucoma who use eye drops daily and adults aged 65+ without glaucoma who do not regularly use eye drops.

View Article and Find Full Text PDF

Background: To describe clinical features, risk factors and outcomes of out-of-the-bag (OTB) intraocular lens (IOL) dislocation in dead bag syndrome (DBS).

Methods: Retrospective review of a single-surgeon series of eyes with IOLs that developed OTB IOL dislocation, managed at Singapore National Eye Centre (January 2014-December 2021), with a minimum of 6 months of follow-up. Eyes with OTB IOL dislocation following secondary IOL implantation and intraoperative capsule complications were excluded.

View Article and Find Full Text PDF

Purpose: To evaluate visual, anatomical and safety outcomes of aflibercept 8 mg in previously treated patients with neovascular age-related macular degeneration (nAMD).

Methods: This retrospective study included nAMD patients switched to aflibercept 8 mg from prior anti-VEGF therapies at Sahlgrenska University Hospital between February 2024 and February 2025. Data on best-corrected visual acuity (BCVA), central retinal thickness (CRT), pigment epithelial detachment (PED) height, fluid status, treatment intervals, time to fluid recurrence and adverse events were collected.

View Article and Find Full Text PDF

Two patients (a 7-year-old female and a 61-year-old male) had poor intraocular pressure control after XEN gel stent implantation. During the process of filtering bleb repair, the XEN gel implant retreated into the anterior chamber, and the limbal and corneal incisions were made. After the implant in the anterior chamber was taken out, it was implanted into the anterior chamber again from the original scleral tunnel for the female patient, while it was re-punctured into the anterior chamber with a 1-ml syringe needle at another site for the male patient.

View Article and Find Full Text PDF

The prevalence of normal tension glaucoma (NTG) in China stands at 1%. The inappropriate demarcation of normal intraocular pressure values may lead to misdiagnosis. The Glaucoma Group of Ophthalmology Branch of Chinese Medical Association released the consensus on the diagnosis and treatment of NTG in 2019, which established important clinical guidelines for the NTG management.

View Article and Find Full Text PDF