Article Abstract

Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) is a well-established technique for evaluating myocardial perfusion and function in patients with suspected or known coronary artery disease. While conventional dual-detector SPECT scanners have limitations in spatial resolution and photon detection sensitivity, recent advancements, including full-ring solid-state cadmium zinc telluride (CZT) detectors, offer enhanced image quality and improved diagnostic accuracy. This study aimed to compare the performance of Veriton-CT, a full-ring CZT SPECT system, with GE Discovery 530c, a dedicated cardiac fixed-angle gamma camera, in myocardial perfusion imaging and their correlation with coronary angiography findings. This was a prospective study that analyzed 21 patients who underwent MPI at the Department of Nuclear Medicine, Lithuanian University of Health Sciences, Kauno Klinikos. A one-day stress-rest protocol using 99mTc-Sestamibi was employed, with stress testing performed via bicycle ergometry or pharmacological induction. MPI was first conducted using GE Discovery 530c (GE Health Care, Boston, MA, USA), followed by imaging on Veriton-CT, which included low-dose CT for attenuation correction. The summed stress score (SSS), summed rest score (SRS), and summed difference score (SDS) were analyzed and compared between both imaging modalities. Coronary angiography results were retrospectively collected, and lesion-based analysis was performed to assess the correlation between imaging results and the presence of significant coronary artery stenosis (≥35% and ≥70% narrowing). Image quality and the certainty of distinguishing the inferior myocardial wall from extracardiac structures were also evaluated by two independent researchers with differing levels of experience. : Among the 14 patients included in the final analysis, Veriton-CT was more likely to classify MPI scans as normal (64.3%) compared to GE Discovery 530c (28.6%). Additionally, Veriton-CT provided a better assessment of the right coronary artery (RCA) basin, showing greater agreement with coronary angiography findings than GE Discovery 530c, although the difference was not statistically significant. No significant differences in lesion overlap were observed for the left anterior descending artery (LAD) or left circumflex artery (LCx) basins. Furthermore, the image quality assessment revealed slightly better delineation of extracardiac structures using Veriton-CT (Spectrum Dynamics Medical, Caesarea, Israel), particularly when evaluated by an experienced researcher. However, no significant difference was observed when assessed by a less experienced observer. Our findings suggest that Veriton-CT, with its full-ring CZT detector system, may offer advantages over fixed-angle gamma cameras in improving image quality and reducing attenuation artifacts in MPI. Although the difference in correlations with coronary angiography findings was not statistically significant, Veriton-CT showed a trend toward better agreement, particularly in the RCA basin. These results indicate that full-ring SPECT imaging could improve the diagnostic accuracy of non-invasive MPI, potentially reducing the need for unnecessary invasive angiography. Further studies with larger patient cohorts are required to confirm these findings and evaluate the clinical impact of full-ring SPECT technology in myocardial perfusion imaging.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12028854PMC
http://dx.doi.org/10.3390/medicina61040665DOI Listing

Publication Analysis

Top Keywords

myocardial perfusion
20
perfusion imaging
16
image quality
16
discovery 530c
16
coronary angiography
16
fixed-angle gamma
12
coronary artery
12
angiography findings
12
spect myocardial
8
imaging
8

Similar Publications

Blood perfusion in cardiac tissues involves intricate interactions among vascular networks and tissue mechanics. Perfusion deficit is one of the leading causes of cardiac diseases, and modeling certain cardiac conditions that are clinically infeasible, invasive, or costly can provide valuable supplementary insights to aid clinicians. However, existing homogeneous perfusion models lack the complexity required for patient-specific simulations.

View Article and Find Full Text PDF

Evaluation of the usefulness of the masking on un-smoothed image method in Tl myocardial perfusion SPECT.

Radiol Phys Technol

September 2025

Department of Cardiovascular Internal Medicine, NHO Kagoshima Medical Center, 8-1, Shiroyamacho, Kagoshima, Kagoshima, 892-0853, Japan.

In Tl myocardial perfusion single-photon emission computed tomography (SPECT), gastric wall uptake can impact the inferior wall. This study aimed to evaluate the effectiveness and usefulness of the masking on un-smoothed image (MUS) method for Tl myocardial perfusion SPECT. A hemispherical gastric wall phantom was created to simulate the gastric fundus located closest to the myocardium, and the activity was enclosed to achieve an SPECT count ratio against the myocardium equivalent to that observed in clinical practice.

View Article and Find Full Text PDF

Myocardial Perfusion Imaging and Revascularization Predict Long-term All-cause Mortality in Patients with Suspected CAD.

Acad Radiol

September 2025

Department of Nuclear Medicine, National Taiwan University Hospital, Taipei, Taiwan (J.Y.H., C.L.K., K.L.C.); College of Medicine, National Taiwan University, Taipei, Taiwan (J.Y.H., C.K.H., K.L.C., Y.W.W.); Department of Internal Medicine, National Taiwan University Hospital, Taipei, Taiwan (C.K

Rationale And Objectives: The prognostic implications of myocardial perfusion imaging (MPI) are imperative to provide proper management of coronary artery disease (CAD). This study aimed to quantify the long-term prognostic value of MPI under routine clinical conditions.

Materials And Methods: This single-center retrospective cohort study evaluated all-cause mortality and cause-specific survival according to MPI findings in patients with suspected or known CAD who underwent diagnostic evaluation or assessment of myocardial ischemia and viability in a tertiary referral cardiovascular center.

View Article and Find Full Text PDF

Diagnostic reference levels (DRLs) are essential for optimizing radiologic practices and ensuring patient safety. This study aimed to establish typical DRLs for nuclear medicine (NM) procedures performed at a Brazilian public university hospital. A retrospective analysis of 2,609 patient records from 13 routine NM procedures was conducted.

View Article and Find Full Text PDF

Cardioplegic Machine Perfusion of Hearts Donated after Circulatory Death.

J Cardiovasc Transl Res

September 2025

Department of Cardiac Surgery, University Hospital Halle (Saale), University of Halle, Ernst-Grube-Straße 40, 06120, Halle (Saale), Germany.

We compared the effects of ex-vivo machine perfusion (EVMP) of hearts donated after circulatory death (DCD) with the single-shot solutions HTK-N and Del Nido cardioplegia (DNC) on left-ventricular (LV) contractility and myocardial microcirculation. In a DCD pig model, hearts were maintained by EVMP with hypothermic, oxygenated HTK-N (DCD-HTK-N; N = 8) or DNC (DCD-DNC; N = 8) followed by reperfusion with blood, including assessment of contractility and microcirculation with Laser-Doppler-Flow (LDF). We performed transcriptomics using microarrays.

View Article and Find Full Text PDF