Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A 75-year-old woman presented with scalp and cranial defects caused by implant exposure, infection,and cranial necrosis following multiple craniotomies. To reduce the risk of complications after cranioplasty, weplanned a two-stage cranial reconstruction. A wide bipedicled scalp flap with a long longitudinal axis above the cranium covered the scalp defect after debridement, and skin grafting was performed on the periosteum after flap harvesting during the first surgery. A custom-made titanium plate was implanted under the bipedicled flap during the second cranioplasty 4 months after the initial surgery. The patient had no complications during the two surgeries, and her clinical course was uneventful for 6 months after the last surgery. Although a two-stage approach, our technique is relatively safe for patients who have previously undergone multiple surgeries and decreases the risk of postoperative complications due to the shorter exposure time of the titanium plate during the second surgery. J. Med. Invest. 72 : 185-188, February, 2025.

Download full-text PDF

Source
http://dx.doi.org/10.2152/jmi.72.185DOI Listing

Publication Analysis

Top Keywords

titanium plate
12
two-stage cranial
8
cranial reconstruction
8
custom-made titanium
8
bipedicled scalp
8
scalp flap
8
reconstruction custom-made
4
plate preliminary
4
preliminary bipedicled
4
scalp
4

Similar Publications

Study of a near-cortical over-drilling technique on plate constructs with a conical locking system in a rabbit femoral fracture using a finite element model.

Med Eng Phys

October 2025

Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:

This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.

View Article and Find Full Text PDF

Comparative clinical efficacy of nickel-titanium shape memory staples versus miniplate for Bartoníček-Rammelt type III and IV posterior malleolar fractures. A retrospective analysis of 47 consecutive patients treated between January 2022 and June 2024 documented operative time, intraoperative blood loss, fluoroscopy times, healing time, complications, postoperative fracture gap distance (mm), and articular surface step-off (mm) at the ankle joint. Ankle function was assessed using the American Orthopaedic Foot and Ankle Society (AOFAS) ankle-hindfoot score, the Manchester-Oxford Foot Questionnaire (MOXFQ), and range of motion measurements at 3, 6, 12, and 14 months.

View Article and Find Full Text PDF

Segmental mandibulectomy is a valid treatment for advanced medication-related osteonecrosis of the jaw (MRONJ), but subsequent reconstruction is challenging. Spontaneous bone regeneration (SBR) following resection is exceedingly rare, particularly in the elderly. We present the case of a 63-year-old woman with stage 3 MRONJ who underwent a 60 mm segmental mandibulectomy.

View Article and Find Full Text PDF

Background/objective: Plate failure, including bending, is a critical issue in orthopedic fracture fixation, with clinical failure rates of 3.5%-19%, burdening patients and healthcare systems. Preclinical ovine models have observed similar plate bending due to overloading.

View Article and Find Full Text PDF

The patient-specific mandibular reconstruction plate (PSMRP) has gained prominence for its precise adaptation to mandibular contours and reported enhanced mechanical reliability compared to the manual-bent mandibular reconstruction plate (MBMRP). Despite this, a biomechanical comparison between MBMRP and PSMRP is essential for informed clinical decision-making and advancing the field of mandibular reconstruction. Thereupon, biomechanical behavior was compared between two reconstructed mandibles with the MBMRP made of commercial pure titanium plate and the PSMRP stemmed from a common ramus reconstruction case, respectively, in physiological simulation using finite element analyses.

View Article and Find Full Text PDF