A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Evaluation of the Toumai robotic system in partial nephrectomy and key system features. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Robotic partial nephrectomy is a standard procedure in urology, but its widespread use is limited by the high cost and technical constraints of current systems. New robotic systems are being developed to enhance affordability and accessibility, expanding the availability of advanced robotic surgery to a broader range of healthcare facilities and patients. This study evaluates the feasibility and safety of the Toumai system in partial nephrectomy, examining its advanced features and their potential impact on surgical precision and operational efficiency. In this single center study, eleven patients underwent partial nephrectomy using Toumai. Primary endpoints were feasibility and safety, while secondary outcomes included perioperative outcomes. All surgeries were completed successfully without conversion, minimal complications, and no major equipment failures. The median operative time was 107 min, docking time was 8 min, and estimated blood loss was 50 ml. One off-clamp partial nephrectomy was successfully performed and median warm ischemia time was 9 min in the remaining cases. Postoperatively, renal function remained stable, and surgical margins were negative in all cases. These preliminary results suggest that partial nephrectomy can be safely performed using the Toumai robotic system. The system's advanced features, including sensory feedback, high-frequency response, and enhanced imaging technologies, likely contributed to favorable surgical outcomes with minimal complications. However, these initial findings warrant further validation through larger studies and longer follow-up.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12003781PMC
http://dx.doi.org/10.1038/s41598-025-97124-xDOI Listing

Publication Analysis

Top Keywords

partial nephrectomy
24
toumai robotic
8
robotic system
8
system partial
8
feasibility safety
8
advanced features
8
minimal complications
8
partial
6
nephrectomy
6
robotic
5

Similar Publications