Article Abstract

In order to achieve rapid detection of oil quality, an innovative small-scale oil joint detection system is designed in this paper. The joint detection system combines a micro-distillation instrument and Raman spectrometer module through a combination module. The basic principle is to use a Raman spectrometer to detect the distillate in the micro-distillation instrument in order to predict the properties of the oil and determine its quality. The system uses Savitzy-Golay smoothing, baseline correction, normalization processing, partial least squares, and other methods for data fitting to ensure the authenticity and comparability of the measured data. Fourteen different sources and grades of diesel oil are selected in this paper for pre-experiments to verify the data fitting effect. Two oil samples, No. 1-10 diesel oil 1 with strong fluorescence interference and No. 2-10 diesel oil 2 with weak fluorescence interference, were used as test objects to compare the Raman spectra of undistilled oil and distilled oil, verify the testing effect of the joint detection system, and analyze the mechanism of fluorescence interference mainly existing in the heavy components of the oil. The test results show that the joint detection system can quickly detect the quality of different grades of diesel oil, with good smoothness, obvious characteristic bands, and good data fitting. The joint detection system designed in this paper has the advantages of high sensitivity, high integration, and small size, laying the foundation for research related to distillation ranges combined with Raman spectroscopy technology.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11991230PMC
http://dx.doi.org/10.3390/s25072130DOI Listing

Publication Analysis

Top Keywords

joint detection
20
detection system
20
diesel oil
16
data fitting
12
fluorescence interference
12
oil
11
raman spectroscopy
8
spectroscopy technology
8
system designed
8
designed paper
8

Similar Publications

Objectives: To systematically review and meta-analyse the risk factors proposed by the American College of Rheumatology and American College of Chest Physicians as screening tools for rheumatoid arthritis-associated interstitial lung disease (RA-ILD), focusing exclusively on studies using high-resolution computed tomography (HRCT) in prospectively collected data from unselected RA patients.

Method: A comprehensive search was conducted to identify studies evaluating RA-ILD risk factors. Selection criteria included studies using HRCT in prospective, unselected RA cohorts.

View Article and Find Full Text PDF

Accurate detection of tandem repeats exposes ubiquitous reuse of biological sequences.

Nucleic Acids Res

September 2025

Department of Biomedical Informatics, University of Pittsburgh, Pittsburgh, PA 15206, United States.

Tandem repetition is one of the major processes underlying genome evolution and phenotypic diversification. While newly formed tandem repeats are often easy to identify, it is more challenging to detect repeat copies as they diverge over evolutionary timescales. Existing programs for finding tandem repeats return markedly different results, and it is unclear which predictions are more correct and how much room remains for improvement.

View Article and Find Full Text PDF

This work aims to investigate the occurrence of 31 antibiotics (ABs), 2 bacteria ( and spp.) and their counterpart antibiotic-resistant bacteria (carbapenem and cephalosporin families), and several antibiotic-resistant genes (ARGs) throughout a full distribution system of reclaimed water (RW) in a real-scale scenario. The RW was analyzed (i) before and after the tertiary treatment (sand filtration and chlorination), (ii) during the storage period in secondary ponds before its use in irrigation, and (iii) directly in the droppers installed in four plastic-based greenhouses over 9 months.

View Article and Find Full Text PDF

Increased Fibroblast-Like Synoviocyte Inflammation in Rheumatoid Arthritis Revealed by Sphingosine 1-Phosphate Receptor 1-Targeting PET/CT Imaging.

Mol Pharm

September 2025

Guangdong Provincial Engineering Research Center of Molecular Imaging, The Fifth Affiliated Hospital, Sun Yat-Sen University, Zhuhai, Guangdong 519000, China.

Rheumatoid arthritis (RA) is a chronic autoimmune disease characterized by joint inflammation. This study aimed to use the sphingosine 1-phosphate receptor 1 (S1PR1) targeted tracer [F]TZ4877 with PET/CT to assess synovial inflammation in a collagen-induced arthritis (CIA) mouse model. [F]TZ4877 and [F]FDG PET/CT imaging were performed on RA ( = 6) and control ( = 6) mice.

View Article and Find Full Text PDF

Localized Gradient Conductivity Enabled Ultrasensitive Flexible Tactile Sensors with Ultrawide Linearity Range.

Adv Mater

September 2025

Key Laboratory of Low Dimensional Quantum Structures and Quantum Control of Ministry of Education, School of Physics and Electronics, Hunan Normal University, Changsha, 410081, China.

The high sensitivity and wide linearity are crucial for flexible tactile sensors in adapting to diverse application scenarios with high accuracy and reliability. However, conventional optimization strategies of constructing microstructures suffer from the mutual restriction between the high sensitivity and wide linearity. Herein, a novel design of localized gradient conductivity (LGC) with partly covered low-conductivity (low-σ) carbon/Polydimethylsiloxane layer on high-conductivity (high-σ) silver nanowires film upon the micro-dome structure is proposed.

View Article and Find Full Text PDF