Severity: Warning
Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests
Filename: helpers/my_audit_helper.php
Line Number: 197
Backtrace:
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url
File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML
File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global
File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword
File: /var/www/html/index.php
Line: 317
Function: require_once
98%
921
2 minutes
20
Prcis: In this multi-institutional effort, we identified gaps in SAP data elements within medical terminologies. We proposed new concepts to LOINC to enhance SAP data standards and big data representation and improve interoperability across health care systems.
Purpose: To identify gaps in the representation of Standard Automated Perimetry (SAP) data elements in Logical Observation Identifiers Names and Codes (LOINC) and the Observational Medical Outcomes Partnership (OMOP) Common Data Model (CDM) and propose solutions for those gaps.
Methods: SAP source data elements and Digital Imaging and Communications in Medicine (DICOM) standard from 2 commonly used perimeter devices were extracted and compared against existing concepts in standardized terminologies using the OMOP CDM Athena browser and LOINC using the LOINC browser. Gap areas were identified and classified following conventions used by Health Level 7 Fast Healthcare Interoperability Resources and discussed within the OHDSI Eye Care and Vision Research Workgroup in iterative rounds aiming to address gaps. New codes were developed upon reaching a consensus and proposed for inclusion in LOINC.
Results: Among 107 data elements extracted from the perimeters, 82% (n=88) of SAP data elements lacked representation. Of the 19 remaining elements, 2.8% (n=3) were wider, 1.9% (n=2) were narrower, and 13% (n=14) had equivalent representation. In addition, only 2.6% (n=3) of the 116 DICOM attributes related to SAP had representation in standardized terminologies. Several existing relevant codes were defined ambiguously or erroneously (eg, visual field index, pupil diameter, perimeter format Kowa).
Conclusion: There is a lack of representation of some SAP data elements in standardized medical terminologies, hampering interoperability and data sharing. We identified gaps and proposed new concepts for addition to LOINC, aiming to improve SAP data standards and interoperability.
Download full-text PDF |
Source |
---|---|
http://dx.doi.org/10.1097/IJG.0000000000002575 | DOI Listing |