A modified Müller-Plathe method capable of quickly establishing an expected temperature difference in classical and molecular dynamics simulations for thermal transport calculations.

Phys Chem Chem Phys

Key Laboratory of Ocean Energy Utilization and Energy Conservation of Ministry of Education, School of Energy and Power Engineering, Dalian University of Technology, Dalian 116024, China.

Published: April 2025


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

The Müller-Plathe method [F. Müller-Plathe, , 1997, , 6082] has been widely used to calculate the thermal transport properties of materials, with the advantages of easy implementation and no external thermostat needed. However, the temperature differences of model systems are uncontrollable in the original Müller-Plathe method, which largely depends on the selected time intervals for velocity exchanges in the molecular dynamics simulations, largely affecting the computational efficiency of the Müller-Plathe-method-based molecular dynamics simulations, especially first-principles calculations. In this paper, we improved the Müller-Plathe method to be capable of establishing the expected temperature difference by introducing a feedback-and-response mechanism into the method. The modified Müller-Plathe method was achieved by dynamically adjusting the heat flux direction in real-time through the proposed feedback-and-response mechanism, which represents a significant departure from the conventional approach of modulating the time interval for velocity exchange in the original Müller-Plathe method, and the prediction efficiency was significantly improved. The modified Müller-Plathe method was further validated by performing a series of classical and molecular dynamics simulations.

Download full-text PDF

Source
http://dx.doi.org/10.1039/d4cp04251dDOI Listing

Publication Analysis

Top Keywords

müller-plathe method
28
molecular dynamics
16
dynamics simulations
16
modified müller-plathe
12
method
8
method capable
8
capable establishing
8
establishing expected
8
expected temperature
8
temperature difference
8

Similar Publications

Introduction: Wave speed (WS) mapping, enabled by omnipolar technology, allows for real-time visualization of local conduction velocity (CV). Its utility in ventricular tachycardia (VT) ablation has not been fully characterized.

Methods And Results: We describe a case series of patients undergoing VT ablation in which WS mapping was applied alongside established techniques such as peak frequency (PF) mapping and isochronal late activation mapping (ILAM).

View Article and Find Full Text PDF

Management of Transvenous Leads in Patients With Iatrogenic Lead Perforation.

J Cardiovasc Electrophysiol

September 2025

Cardiac Electrophysiology Section, Department of Cardiovascular Medicine, Cleveland Clinic, Cleveland, Ohio, USA.

Introduction: Iatrogenic lead perforation is a rare but serious complication of cardiac implantable electronic device (CIED) implantation. Evidence on percutaneous management of subacute or delayed cases remains limited.

Methods: We retrospectively reviewed 38 patients treated for iatrogenic lead perforation between January 2012 and October 2024.

View Article and Find Full Text PDF

Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.

View Article and Find Full Text PDF

Introduction: The role of imaging in radiotherapy is becoming increasingly important. Verification of imaging parameters prior to treatment planning is essential for safe and effective clinical practice.

Methods: This study described the development and clinical implementation of ImageCompliance, an automated, GUI-based script designed to verify and enforce correct CT and MRI parameters during radiotherapy planning.

View Article and Find Full Text PDF