98%
921
2 minutes
20
Background: Primary graft failure (PGF) is a leading cause of early morbidity and mortality after heart transplantation (HTx). PGF is secondary to graft ischemia and ischemia-reperfusion injuries to the cardiomyocytes and vasculature of the donor heart after transplantation. Longer-term outcomes after PGF are not well studied.
Methods: Patients with an HTx (January 1, 2010 to June 30, 2022) were identified using the Pediatric Heart Transplant Society registry. PGF was defined as death, retransplantation, or need for mechanical circulatory support within 72 hours of HTx. Kaplan-Meier analysis and Cox proportional hazard modeling were utilized.
Results: Of the 4,982 patients with a primary HTx, 5.4% ( = 269) met criteria for PGF. Patients with PGF were younger, with higher proportion of congenital heart disease, longer cardiopulmonary bypass and ischemic times (IT), and more likely to be on extracorporeal membrane oxygenation or ventilator at HTx (all < 0.0001, IT = 0.0006). PGF resulted in lower overall survival (1 year: 54% vs 94%, < 0.001). This remained true when conditional survival was examined at 30 and 90 days but not at 1 year ( = 0.1143). Freedom from rejection did not differ between the groups at overall or conditional on 30 days but was slightly higher for those with PGF at 90 and 365 days. There was no difference in freedom from coronary allograft vasculopathy (CAV). PGF was an independent predictor of overall graft loss (hazard ratios [HR] 4.7, < 0.0001) and conditional survival to 30 days (HR 2.47, < 0.0001) and 90 days (HR 1.6, = 0.012) but not beyond 1 year.
Conclusions: Severe PGF is an independent predictor of early mortality post-HTx but subsequently does not further impact long-term survival, overall risk of rejection, or CAV. Understanding the impact of milder forms of PGF on survival and long-term outcomes is still needed. Methods to decrease the risk of PGF, such as alternative preservation and storage techniques, may impact early mortality post-HTx.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11935355 | PMC |
http://dx.doi.org/10.1016/j.jhlto.2024.100184 | DOI Listing |
Nat Rev Nephrol
September 2025
Nuffield Department of Surgical Sciences, University of Oxford, Oxford, UK.
The global shortage of suitable donor kidneys is the primary challenge in kidney transplantation, and it is exacerbated by ageing donors with increased numbers of health issues. Improving organ assessment, preservation and conditioning could enhance organ utilization and patient outcomes. Hypothermic machine perfusion (HMP) is associated with better results than static cold storage by reducing delayed graft function and improving short-term graft survival, especially in kidneys recovered from marginal-quality donors.
View Article and Find Full Text PDFArch Cardiovasc Dis
September 2025
Pharmacie, Nantes Université, CHU de Nantes, 44000 Nantes, France; UFR des Sciences Pharmaceutiques et Biologiques, Nantes Université, 44000 Nantes, France. Electronic address:
Background: Patients with acute coronary syndrome requiring coronary artery bypass graft surgery while on ticagrelor face a high risk of perioperative bleeding because of its strong antiplatelet effect. The Cytosorb® haemoadsorbent membrane (CytoSorbents Corporation, Princeton, NJ, USA), which is CE marked for ticagrelor removal, may help to mitigate this risk.
Aim: To evaluate the cost-revenue impact of the use of Cytosorb® membrane over two different time periods in a high-volume French hospital.
Few reports exist in dentistry about the use of general anesthesia in children after liver transplant. In this paper, we report our experience utilizing general anesthesia for oral surgery in a 9-year-old girl who had undergone living donor liver transplantation. She was diagnosed with hepatoblastoma at 4 months of age and underwent a living donor liver transplant at 7 months of age.
View Article and Find Full Text PDFPerfusion
September 2025
Department of Surgery, Columbia University, New York, NY, USA.
Static cold storage (SCS) on ice has remained the gold standard preservation method for heart transplantation, and prolonged cold ischemia outside the typical 4-6 hour window is associated with an increased risk of primary graft dysfunction - a consequence attributed to ischemic damage and reperfusion injury. This, unfortunately limits the travel radius for donor heart procurement, a key factor that contributes to the overall shortage of donor organs. Recent research and clinical data have illustrated the validity of other preservation systems in preserving cardiac allografts, and many of these devices have shown promise in potentially prolonging the tolerated ischemic time beyond the accepted standard.
View Article and Find Full Text PDFEBioMedicine
September 2025
Cancer Centre, The First Hospital of Jilin University, Changchun, Jilin, 130021, China; Institute of Virology and AIDS Research, The First Hospital of Jilin University, Changchun, Jilin, 130021, China; Institute of Translational Medicine, Key Laboratory of Organ Regeneration and Transplantation of M
Background: Enterovirus D68 (EV-D68) is a prominent non-polio enterovirus known to cause severe respiratory infections and poliomyelitis-like illnesses in children. Recently, we identified MFSD6 as a receptor for EV-D68, providing a potential target for blocking viral entry into cells. This study aimed to develop an MFSD6-based decoy receptor to neutralise EV-D68 and elucidate its mechanism of action.
View Article and Find Full Text PDF