98%
921
2 minutes
20
Our long-term objective is to quantify patient-specific changes in contact mechanics after partial meniscectomy (PM) using knee-specific finite element (FE) models created from clinical MR scans under axial load. Before creating patient-specific models, a validation of our workflow and processes is required. The objective of this study was to validate knee-specific FE models of tibiofemoral joint contact mechanics by comparison to direct measurements of contact by electronic pressure sensors. We hypothesized that knee-specific FE model data would fall within direct measurements of the contact area and pressure values from sensors, but that detected differences in outcomes would be smaller than differences reported after PM. The workflow consisted of performing MRIs on five cadaveric knees using a patient-based loading system adapted to cadaveric knees where loaded and unloaded scans were acquired with and without a sensor in place, segmenting images to develop FE models, running those models with statistical approaches to model material property variation and comparing the model outputs to the outputs quantified physically by sensors. Overall, 53% of outcomes (32/60) from the FE models fell within the ranges of those directly measured. Of the values that fell outside, differences were lower than those identified from a literature review of the mechanical effects of partial meniscectomies, especially when meniscectomies were 30% or 60% of the meniscus volume. FE models developed using this workflow may be helpful in assessing or anticipating changes in joint force redistribution following partial meniscectomies in patients.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12068977 | PMC |
http://dx.doi.org/10.1002/jor.26077 | DOI Listing |
Eur Heart J Case Rep
September 2025
Department of Cardiology, Toyohashi Heart Center, 21-1 Gobutori, Oyamacho, Toyohashi 441-8530, Japan.
Background: Mitral regurgitation (MR) may rarely worsen after transcatheter aortic valve implantation (TAVI) due to mechanical interference from the transcatheter heart valve (THV). Standard surgical approaches in these cases are often challenging due to anatomical constraints. Thus, there is a need for the development of effective alternatives to address this issue.
View Article and Find Full Text PDFAdv Eng Mater
July 2025
Department of Mechanical Engineering University of Nevada, Las Vegas, NV, US.
Highly contagious respiratory infection diseases such as COVID-19 can be transmitted by inhaling virus laden liquid droplets and short-range aerosols, released by an infected person. Particularly, in hospitals, spraying of the respiratory droplets containing pathogens from the conjunctiva or mucus of a susceptible person plays a key role in transferring the infectious diseases. N95 filtering respirators are a critical personal protective equipment.
View Article and Find Full Text PDFNewton
September 2025
Department of Mechanical Engineering, University of Wisconsin-Madison, Madison, Wisconsin, 53706, USA.
In confluent cell monolayers, patterns of cell forces and motion are systematically altered near topological defects in cell shape. In turn, defects have been proposed to alter cell density, extrusion, and invasion, but it remains unclear how the defects form and how they affect cell forces and motion. Here, we studied +1/2 defects, and, in contrast to prior studies, we observed the concurrent occurrence of both tail-to-head and head-to-tail defect motion in the same cell monolayer.
View Article and Find Full Text PDFInt J Biol Macromol
September 2025
Department of Food, Nutrition and Packaging Sciences, Clemson University, Clemson, SC, 29634, USA. Electronic address:
Sepiolite (SP) is a naturally occurring sedimentary silicate clay mineral known for its unique structure, high surface area, and rich surface chemistry, particularly silanol groups (Si-OH), which facilitate strong interfacial interactions in polymer matrices. Its ability to act as a nanofiller has gained attention in the development of advanced biopolymer nanocomposites, especially for food packaging applications where material performance, sustainability, and safety are critical. SP enhances the thermal stability, barrier properties, and mechanical strength of starch and other biopolymer matrices, key factors in extending shelf life.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
September 2025
Education and Research Department, Isokinetic Medical Group, FIFA Medical Centre of Excellence, Bologna, Italy.
Purpose: To describe the mechanisms, situational patterns, biomechanics and neurocognitive errors related ankle sprain injuries of professional male football players during match play.
Methods: There were 166 consecutive ankle sprain injuries identified occurring during official matches in players of top European football leagues. One hundred and forty (84%) injury videos were analysed for mechanism and situational pattern, with biomechanics on 20 players.