Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Introduction: Conventional umbilical venous catheterisation (UVC) relies on 'blind' insertion without ultrasound guidance, resulting in low success and high complication rates. While point-of-care ultrasound (POCUS)-based tip navigation and location has improved this scenario by enabling real-time visualisation of the catheter tip during UVC, challenges remain when the catheter is inadvertently inserted into an incorrect vessel. Selecting effective intervention methods to correct the catheter direction has become a key research focus. This study aims to evaluate the safety and efficacy of a novel technique combining POCUS-guided tip navigation with visualised directional high-frequency linear array probe compression (P-TN+vdHLAP C). This technique is expected to become a standardised protocol for POCUS-guided UVC, improving catheterisation success rates, minimising the frequency of insertion attempts and reducing catheterisation time.

Methods And Analysis: This prospective, multicentre, single-blind, superiority, 1:1 parallel, randomised controlled trial will recruit 100 infants who have failed the initial UVC attempt using the conventional method. Participants will be randomly assigned to either the intervention group receiving P-TN+vdHLAP C or the control group receiving POCUS-guided tip location. The primary outcome measure is the success rate of UVC, defined as the proportion of catheter placements that are successfully positioned at the entrance of the inferior vena cava into the right atrium, as confirmed by POCUS. Secondary outcomes include UVC procedure time, total number of catheter insertions and postoperative monitoring indicators such as catheter tip location, incidence of complications and umbilical catheter indwelling time. Outcome measures will be assessed at seven time points: immediately after catheter placement, 12 hours, 24 hours, 48 hours and 7 days postplacement, catheter removal and discharge. Data analysis will be conducted using R (V.4.3.2).

Ethics And Dissemination: The study protocol has been approved by the ethics committee of Fujian Children's Hospital (protocol number 2024ETKLRK09019). Prior to enrolment, written informed consent will be obtained from the legal guardians of all participants by the study staff. On completion of the trial, the results will be submitted for peer-reviewed publication in an international scientific journal.

Trial Registration Number: ChiCTR2400090737.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11931964PMC
http://dx.doi.org/10.1136/bmjopen-2024-095017DOI Listing

Publication Analysis

Top Keywords

catheter
9
visualised directional
8
directional high-frequency
8
high-frequency linear
8
linear array
8
array probe
8
probe compression
8
success rate
8
umbilical venous
8
venous catheterisation
8

Similar Publications

Introduction: Wave speed (WS) mapping, enabled by omnipolar technology, allows for real-time visualization of local conduction velocity (CV). Its utility in ventricular tachycardia (VT) ablation has not been fully characterized.

Methods And Results: We describe a case series of patients undergoing VT ablation in which WS mapping was applied alongside established techniques such as peak frequency (PF) mapping and isochronal late activation mapping (ILAM).

View Article and Find Full Text PDF

Background: Patent foramen ovale (PFO) has been identified as a potential risk factor for cryptogenic stroke (CS). Although transesophageal echocardiography (TEE) is considered the gold standard for PFO detection, false-negative results remain a clinical concern, particularly in CS patients with high suspicion of PFO-related etiology.

Aims: To evaluate the clinical utility of transcatheter PFO exploration (TPFOE) in CS patients with negative TEE findings but high suspicion of PFO-related etiology.

View Article and Find Full Text PDF

Traditionally, clinical devices are designed, tested and improved through lengthy and expensive laboratory experiments and clinical trials [1]. More recently, computational methods have allowed for rapid testing, speeding up the design process and enabling far more complete searches of design space. While computational models cannot fully capture the complexities of biological systems, they provide valuable insights into crucial underlying mechanisms, such as the effects of fluid-structure interactions (FSIs).

View Article and Find Full Text PDF

Background: Umbilical arterial catheterisation is a common intervention performed in the neonatal intensive care unit (NICU) especially in extremely preterm and extremely low birth weight neonates. Rarely catheter fracture or breakage can occur, leaving behind part of the catheter in the aorta. A handful of cases have been reported in the literature, with the majority being managed surgically.

View Article and Find Full Text PDF