Article Abstract

Background: The purpose of this study was to examine facet contact forces above, below, and at surgical index levels induced by artificial disc implantation and compare the results from spiked versus keeled baseplates comprising the arthroplasty device.

Methods: Human specimens from C2 to C7 were subjected to flexion, extension, and lateral bending prior to, and following random allocation to spiked or keeled cervical arthroplasty at the index (C5-C6), inferior (C6-C7), and superior (C4-C5) levels. Thin film force sensors were inserted unilaterally into the corresponding facets prior to intact testing. Force data was normalized to the minimum forces recorded during each loading mode under each condition, reported as (Max/Min) force ratio and subjected to a 1-way ANOVA with Dunnett's post-hoc tests for comparison to intact specimens.

Results: Under flexion, compared to intact, all levels displayed a significant reduction in force ratio following a 1- and 3-level implantation for the spiked baseplate device. An increase in force ratio was observed at the index level for a 2-level implantation but was mitigated with the completion of a superior device insertion. No statistical differences were noted for keeled devices. In extension, the spiked baseplate device reduced the force ratio for 1- and 2-level implantations. A 3-level insertion did not alter facet force ratios. For the keeled device, no statistical changes were noted. Lateral bending associated with spiked devices resulted in statistically reduced or nonsignificant changes in facet loading ratios. The keeled devices did not display significant changes to facet force ratios.

Conclusions: Implantation of multilevel disc devices can reduce or sustain unaltered facet loading conditions. In general, 3-level arthroplasty statistically reduced or does not increase facet force ratios compared to intact values. The use of spiked versus keel device baseplates is a clinical selection involving anterior/posterior placement and endplate degeneration conditions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11907212PMC
http://dx.doi.org/10.1016/j.xnsj.2024.100512DOI Listing

Publication Analysis

Top Keywords

force ratio
16
spiked versus
12
facet force
12
force
9
versus keeled
8
keeled baseplates
8
lateral bending
8
compared intact
8
spiked baseplate
8
baseplate device
8

Similar Publications

Objectives: To estimate the association between socioeconomic background (derived from household main earner occupation when the survey respondent was aged 14 years old) and likelihood of working as a doctor in adulthood in the UK, and estimate how associations varied over time for respondents who turned 18 years old in different decades.

Design: Observational study of 10 years of pooled data from a nationally representative government survey.

Setting: The United Kingdom (UK).

View Article and Find Full Text PDF

The interactions of three berberine mid-chain fatty acid salts ([BBR][C], n = 6, 7, 8) with lysozyme (Lyz) are investigated in detail using multi-spectroscopic and molecular docking techniques. Steady-state fluorescence and UV-visible absorption experiments suggest that the binding mechanism of [BBR][C] on Lyz is a static quenching with a binding ratio of 1:1. The compound [BBR][C] exhibits a moderate binding affinity toward Lyz.

View Article and Find Full Text PDF

Sectionally nonlinearly functionally graded (SNFG) structures with triply periodic minimal surface (TPMS) are considered ideal for bone implants because they closely replicate the hierarchical, anisotropic, and porous architecture of natural bone. The smooth gradient in material distribution allows for optimal load transfer, reduced stress shielding, and enhanced bone ingrowth, while TPMS provides high mechanical strength-to-weight ratio and interconnected porosity for vascularization and tissue integration. Wherein, The SNFG structure contains sections with thickness that varies nonlinearly along their length in different patterns.

View Article and Find Full Text PDF

Surface-Driven Electron Localization and Defect Heterogeneity in Ceria.

J Am Chem Soc

September 2025

Kathleen Lonsdale Materials Chemistry, Department of Chemistry, University College London, London WC1H 0AJ, U.K.

The exceptional performance of ceria (CeO) in catalysis and energy conversion is fundamentally governed by its defect chemistry, particularly oxygen vacancies. The formation of each oxygen vacancy (V) is assumed to be compensated by two localized electrons on cations (Ce). Here, we show by combining theory with experiment that while this 1 V: 2Ce ratio accounts for the global charge compensation, it does not apply at the local scale, particularly in nanoparticles.

View Article and Find Full Text PDF

Background: It has not been established how electromyographic (EMG) data of masticatory muscles can estimate bite force (BF) during daily activities at home, such as eating and bruxism, utilising the EMG-BF correlation.

Objective: This study aimed to investigate the relationship between actual BF and BF estimated using corresponding EMG data and additional information on BF and EMG measured on a separate day.

Methods: Participants were 16 volunteers.

View Article and Find Full Text PDF