Background: Magnetic resonance imaging (MRI) is an essential brain imaging tool, but its long acquisition times make it highly susceptible to motion artifacts that can degrade diagnostic quality.
Purpose: This work aims to develop and evaluate a novel physics-informed motion correction network, termed PI-MoCoNet, which leverages complementary information from both the spatial and -space domains. The primary goal is to robustly remove motion artifacts from high-resolution brain MRI images without explicit motion parameter estimation, thereby preserving image fidelity and enhancing diagnostic reliability.
Materials And Methods: PI-MoCoNet is designed as a dual-network framework consisting of a motion detection network and a motion correction network. The motion detection network employs a U-net architecture to identify corrupted -space lines using a spatial averaging module, thereby reducing prediction uncertainty. The correction network, inspired by recent advances in U-net architectures and incorporating Swin Transformer blocks, reconstructs motion-corrected images by leveraging three loss components: the reconstruction loss , a learned perceptual image patch similarity (LPIPS) loss, and a data consistency loss that enforces fidelity in the -space domain. Realistic motion artifacts were simulated by perturbing phase encoding lines with random rigid transformations. The method was evaluated on two public datasets (IXI and MR-ART). Comparative assessments were made against baseline models, including Pix2Pix GAN, CycleGAN, and a conventional U-net, using quantitative metrics such as peak signal-to-noise ratio(PSNR), structural similarity index measure (SSIM), and normalized mean square error (NMSE).
Results: PI-MoCoNet demonstrated significant improvements over competing methods across all levels of motion artifacts. On the IXI dataset, for minor motion artifacts, PSNR improved from 34.15 dB in the motion-corrupted images to 45.95 dB after correction, SSIM increased from 0.87 to 1.00, and NMSE was reduced from 0.55% to 0.04%. For moderate artifacts, PSNR increased from 30.23 dB to 42.16 dB, SSIM from 0.80 to 0.99, and NMSE from 1.32% to 0.09%. In the case of heavy artifacts, PSNR improved from 27.99 dB to 36.01 dB, SSIM from 0.75 to 0.97, and NMSE decreased from 2.21% to 0.36%. On the MR-ART dataset, PSNR values increased from 23.15 dB to 33.01 dB for low artifact levels and from 21.23 dB to 31.72 dB for high artifact levels; concurrently, SSIM improved from 0.72 to 0.87 and from 0.63 to 0.83, while NMSE decreased from 10.08% to 6.24% and from 14.77% to 8.32%, respectively. An ablation study further confirmed that incorporating both data consistency and perceptual losses led to an approximate 1 dB gain in PSNR and a reduction of 0.17% in NMSE compared to using the reconstruction loss alone.
Conclusions: PI-MoCoNet is a robust, physics-informed framework for mitigating brain motion artifacts in MRI. It successfully integrates spatial and -space information to enhance image quality. Its superior performance over comparative methods highlights its potential for clinical application, particularly in settings where patient motion is unavoidable. The source code is available at: https://github.com/mosaf/PI-MoCoNet.git.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11844622 | PMC |
Phys Eng Sci Med
September 2025
Department of Radiology, Otaru General Hospital, Otaru, Hokkaido, Japan.
In lung CT imaging, motion artifacts caused by cardiac motion and respiration are common. Recently, CLEAR Motion, a deep learning-based reconstruction method that applies motion correction technology, has been developed. This study aims to quantitatively evaluate the clinical usefulness of CLEAR Motion.
View Article and Find Full Text PDFRadiol Adv
September 2024
Department of Radiology, Northwestern University and Northwestern Medicine, Chicago, IL, 60611, United States.
Background: In clinical practice, digital subtraction angiography (DSA) often suffers from misregistration artifact resulting from voluntary, respiratory, and cardiac motion during acquisition. Most prior efforts to register the background DSA mask to subsequent postcontrast images rely on key point registration using iterative optimization, which has limited real-time application.
Purpose: Leveraging state-of-the-art, unsupervised deep learning, we aim to develop a fast, deformable registration model to substantially reduce DSA misregistration in craniocervical angiography without compromising spatial resolution or introducing new artifacts.
Med Phys
September 2025
Department of Radiology, Stony Brook University, New York, USA.
Background: In contrast-enhanced digital mammography (CEDM) and contrast-enhanced digital breast tomosynthesis (CEDBT), low-energy (LE) and high-energy (HE) images are acquired after injection of iodine contrast agent. Weighted subtraction is then applied to generate dual-energy (DE) images, where normal breast tissues are suppressed, leaving iodinated objects enhanced. Currently, clinical systems employ a dual-shot (DS) method, where LE and HE images are acquired with two separate exposures.
View Article and Find Full Text PDFMed Phys
September 2025
Department of Health Technology and Informatics, The Hong Kong Polytechnic University, Hong Kong SAR, China.
Background: Four-dimensional magnetic resonance imaging (4D-MRI) holds great promise for precise abdominal radiotherapy guidance. However, current 4D-MRI methods are limited by an inherent trade-off between spatial and temporal resolutions, resulting in compromised image quality characterized by low spatial resolution and significant motion artifacts, hindering clinical implementation. Despite recent advancements, existing methods inadequately exploit redundant frame information and struggle to restore structural details from highly undersampled acquisitions.
View Article and Find Full Text PDFNMR Biomed
October 2025
Biomedical Engineering, University of Michigan, Ann Arbor, Michigan, USA.
Understanding gastric physiology in rodents is critical for advancing preclinical neurogastroenterology research. However, existing techniques are often invasive, terminal, or limited in resolution. This study aims to develop a non-invasive, standardized MRI protocol capable of capturing whole-stomach dynamics in anesthetized rats with high spatiotemporal resolution.
View Article and Find Full Text PDF