Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ultrasound localization microscopy (ULM) enabled high-accuracy measurements of microvessel flow beyond the resolution limit of conventional ultrasound imaging by utilizing contrast microbubbles (MBs) as point targets. Robust tracking of MBs is an essential task for fast and high-quality ULM image reconstruction. Existing MB tracking methods suffer from challenging imaging scenarios such as high-density MB distributions, fast blood flow, and complex flow dynamics. Here we present a deep learning-based MB pairing and tracking method based on a bi-directional long short-term memory neural network for ULM. The proposed method integrates multiparametric MB characteristics to facilitate more robust and accurate MB pairing and tracking. The method was validated on a simulation data set, a tissue-mimicking flow phantom, and on a mouse and rat brain.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11844412PMC
http://dx.doi.org/10.1101/2025.02.10.637352DOI Listing

Publication Analysis

Top Keywords

ultrasound localization
8
localization microscopy
8
bi-directional long
8
long short-term
8
short-term memory
8
memory neural
8
neural network
8
pairing tracking
8
tracking method
8
tracking
5

Similar Publications

Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.

View Article and Find Full Text PDF

Background: Thyroid nodules (TNs) are frequent and often benign. Accurately differentiating between benign and malignant nodules is crucial for proper management. This research aims to use ultrasonography to examine TNs and identify possible risk factors in order to improve patient outcomes and diagnostic accuracy.

View Article and Find Full Text PDF

Background: With the advancement of MR-based imaging, prostate cancer ablative therapies have seen increased interest to reduce complications of prostate cancer treatment. Although less invasive, they do carry procedural risks, including rectal injury. To date, the medicolegal aspects of ablative therapy remain underexplored.

View Article and Find Full Text PDF

3D isotropic FastView MRI localizer allows reliable torsion measurements of the lower limb.

Eur Radiol Exp

September 2025

Department of Orthopaedics and Trauma Surgery, Orthopaedic Oncology, Musculoskeletal University Center Munich (MUM), University Hospital, LMU Munich, Munich, Germany.

Computed tomography (CT) and magnetic resonance imaging (MRI) are commonly used to assess femoral and tibial torsion. While CT offers high spatial resolution, it involves ionizing radiation. MRI avoids radiation but requires multiple sequences and extended acquisition time.

View Article and Find Full Text PDF

Autism is a neurodevelopmental condition associated with altered resting-state brain function. An increased excitation-inhibition ratio is discussed as a pathomechanism but in-vivo evidence of disturbed neurotransmission underlying functional alterations remains scarce. We compare local resting-state brain activity and neurotransmitter co-localizations between autism (N = 405, N = 395) and neurotypical controls (N = 473, N = 474) in two independent cohorts and correlate them with excitation-inhibition changes induced by glutamatergic (ketamine) and GABAergic (midazolam) medication.

View Article and Find Full Text PDF