Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

ObjectiveThis study aims to compare the efficacy and safety of Proximal Femoral Nail Anti-Rotation (PFNA) versus Dynamic Hip Screw (DHS) in the treatment of intertrochanteric fractures (IF) in elderly patients. We specifically evaluate perioperative indicators, postoperative hip function, and the rate of internal fixation failure.Methods300 elderly IF patients treated in our hospital from July 2018 to May 2022 were divided into the PFNA group (n = 150), control group (n = 150), PFNA group treated with PFNA, and control group treated with mobility hip screw (DHS). Perioperative bleeding, operation time, postoperative time and hospital time were observed in the two groups: fracture reduction, hip function at 1 and 6 months after surgery, and failure of internal fixation. Observe the postoperative internal fixation failure in the PFNA group.ResultsThe intraoperative blood loss, operation time, first postoperative time and hospital time in the PFNA group were less than in the control group (P < 0.05). One month after surgery, the Harris score of the PFNA group was less than that of the control group (P < 0.05); the Harris score was not different at 6 months (P > 0.05). The excellent rate of fracture reduction in the PFNA group was greater than that in the control group (P < 0.05). The failure rate of internal fixation in the PFNA group was less than that in the control group (P < 0.05). By univariate analysis, Sing Index classification, Evans classification, 25 min and underlying disease were risk factors for postoperative internal fixation failure in PFNA patients (P < 0.05). After multivariate Logistic regression analysis, Sing Index grade, Evans classification, and tip distance 25min were independent risk factors for postoperative internal fixation failure in PFNA patients (P < 0.05).ConclusionThe treatment of elderly IF patients with PFNA has the advantages of small trauma, good fracture reduction, firm internal fixation, low failure rate of internal fixation, and quick postoperative recovery. Sing index classification, Evans classification, and 25min tip distance mainly caused internal fixation failure in patients with PFNA.

Download full-text PDF

Source
http://dx.doi.org/10.1177/09287329241307391DOI Listing

Publication Analysis

Top Keywords

internal fixation
16
elderly patients
12
pfna group
12
control group
12
postoperative internal
8
hip screw
8
screw dhs
8
hip function
8
group n = 150
8
group treated
8

Similar Publications

Purpose: This study aimed to compare the clinical outcomes and cost-effectiveness of two widely used intramedullary fixation systems-the Proximal Femoral Nail Antirotation (PFNA) and the Proximal Femoral Nail with Talon Locking System (PFN-TLS)-in the treatment of intertrochanteric femur fractures (ITFF).

Methods: A retrospective cohort study was conducted on 118 patients aged 65-90 years who underwent surgical treatment for ITFF using either PFNA (n = 53) or PFN-TLS (n = 65). All patients were followed for a minimum of 24 months.

View Article and Find Full Text PDF

Objective: To explore the clinical efficacy of internal fixation of locking compression plate and Cannulated Screw in treatment of elderly femoral neck fractures.

Methods: 175 patients with femoral neck fractures admitted to our hospital from January 2022 to December 2022 were enrolled in the study. 93 cases in the control group were treated with Cannulated Screw internal fixation, and 82 cases in the observation group were treated with locking plate internal fixation.

View Article and Find Full Text PDF

Background: The treatment of mandibular angle fractures remains controversial, particularly regarding the method of fixation. The primary aim of this study was to compare surgical outcomes following treatment with 1-plate versus 2-plate fixation across two oral and maxillofacial surgery clinics. The secondary aim was to evaluate associations between patient-, trauma-, and procedure-specific factors with postoperative complications and to identify high-risk patients for secondary osteosynthesis.

View Article and Find Full Text PDF

Study of a near-cortical over-drilling technique on plate constructs with a conical locking system in a rabbit femoral fracture using a finite element model.

Med Eng Phys

October 2025

Centre for Simulation in Bioengineering, Biomechanics and Biomaterials (CS3B), Department of Mechanical Engineering, School of Engineering of Bauru, São Paulo State University (UNESP), Bauru, São Paulo, Brazil. Electronic address:

This study aimed to evaluate the near-cortical over-drilling technique on the mechanical behaviour of bone-plate constructs in a rabbit transverse femoral fracture. In vitro biomechanical testing and finite element (FE) models were used for analyses. Rabbits' bones (n = 14) were divided into two groups: G1 - without near-cortical over-drilling, and G2 - with near-cortical over-drilling.

View Article and Find Full Text PDF

Histological preparation paraffin embedding is the gold standard method for evaluating tissue structure and composition, whether it is originated from biopsy or engineered . Quite often, deformation and shrinkage occur during the histological preparation, which are difficult to predict and qualify. The present study investigates the morphometric changes in bioprinted hydrogels composed of alginate and gelatine, common tissue engineering materials, focusing on three morphologies: full slabs, porous slabs, and porous cubes.

View Article and Find Full Text PDF