Article Abstract

To determine dose-optimized image acquisition parameters for good image quality (IQ) in neonatal chest radiography with a computed radiography (CR) CsBr needle detector vs. a wireless digital radiography (DR) CsI detector using different doses and filters.Physical resolution of the two detectors in unprocessed imaging of a contrast-detail phantom was automatically evaluated. Post-processed chest radiographic imaging of a neonatal phantom was used for Visual Grading Analysis (VGA) by three radiology raters. Different kVp, mAs, and filter settings were used. The VGA score (VGAS) and dose area product (DAP) were used to determine image acquisition parameters and dose levels for good image quality. Pixel data from segments corresponding to visual grading characteristics (VGC) was used to calculate signal-to-noise ratio, contrast-to-noise ratio (CNR), and signal profile curves. These results were compared to the raters' "ground truth" by Spearman's correlation.The CR detector had the highest resolution in unprocessed imaging, although this was dependent on a tube voltage of 66 kVp (P < 0.001), and more so than the DR detector. The VGAS showed no significant difference between the CR needle and the DR CsI detectors at the same DAP, or when using standard pediatric filtering of 3.5 mm Al + 0.1 mm Cu (P > 0.05). A lung dose level of 0.017 mSv was needed for good IQ (effective dose (): 0.010 mSv). This was achievable with different acquisition parameters. Out of 24 segments, only the CNR of bone-to-soft-tissue had a good Spearman's correlation (ρ > 0.50) to raters' VGAS (P < 0.0001), mostly due to problems with image registration.The CR needle and DR CsI detectors have comparable IQ in neonatal chest radiography. In this study, an of approximately 0.010 mSv was needed for good IQ. · CR needle and DR detectors have comparable image quality in neonatal chest radiography.. · CR needle technology has higher absolute raw image resolution, although this is voltage-dependent and more so than the DR detector.. · We propose ideal image acquisition parameters for neonatal chest radiography.. · Rama K, Esser M, Spogis J et al. Dose-Optimized Image Acquisition Parameters for Neonatal Chest Radiography: A Phantom Study Comparing Computed Radiography and Wireless Digital Radiography Needle Detectors. Rofo 2025; DOI 10.1055/a-2525-9430.

Download full-text PDF

Source
http://dx.doi.org/10.1055/a-2525-9430DOI Listing

Publication Analysis

Top Keywords

acquisition parameters
24
neonatal chest
24
chest radiography
24
image acquisition
20
dose-optimized image
12
parameters neonatal
12
radiography
12
computed radiography
12
wireless digital
12
digital radiography
12

Similar Publications

Importance: Consumer wearable technologies have wide applications, including some that have US Food and Drug Administration clearance for health-related notifications. While wearable technologies may have premarket testing, validation, and safety evaluation as part of a regulatory authorization process, information on their postmarket use remains limited. The Stanford Center for Digital Health organized 2 pan-stakeholder think tank meetings to develop an organizing concept for empirical research on the postmarket evaluation of consumer-facing wearables.

View Article and Find Full Text PDF

This study introduces a novel optimization framework for cranial three-dimensional rotational angiography (3DRA), combining the development of a brain equivalent in-house phantom with Figure of Merit (FOM) a quantitative evaluation method. The technical contribution involves the development of an in-house phantom constructed using iodine-infused epoxy and lycal resins, validated against clinical Hounsfield Units (HU). A customized head phantom was developed to simulate brain tissue and cranial vasculature for 3DRA optimization.

View Article and Find Full Text PDF

Time-resolved data acquisition is crucial for compositional analysis using Laser-Induced Breakdown Spectroscopy (LIBS). It can be managed by adjusting the delay time and gate width of the spectrometer. This study describes the compositional analysis of molybdenum (Mo) ore utilizing charge coupled device (CCD) and intensified charge-coupled device (ICCD) based LIBS systems.

View Article and Find Full Text PDF

Patients with inflammation-associated coronary artery disease (CAD) may exhibit rapid progression and require regular coronary imaging. To evaluate the diagnostic performance of spectral photon-counting detector (PCD) coronary CTA with reduced radiation and contrast media doses for detecting coronary stenosis and in-stent restenosis in patients with inflammation-associated CAD. This prospective study enrolled patients with inflammation-associated CAD from January 2023 to March 2024.

View Article and Find Full Text PDF

This review is intended as a guideline for beginners in confocal laser scanning microscopy. It combines basic theoretical concepts, such as fluorescence principles, resolution limits, and imaging parameters with practical guidance on sample preparation, staining strategies, and data acquisition using confocal microscopy. The aim is to combine technical and methodological aspects in order to provide a comprehensive and accessible introduction.

View Article and Find Full Text PDF