Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: Recent studies utilized ocular images and deep learning (DL) to predict refractive error and yielded notable results. However, most studies did not address biases from imbalanced datasets or conduct external validations. To address these gaps, this study aimed to integrate the deep imbalanced regression (DIR) technique into ResNet and Vision Transformer models to predict refractive error from retinal photographs.

Design: Retrospective study.

Subjects: We developed the DL models using up to 103 865 images from the Singapore Epidemiology of Eye Diseases Study and the United Kingdom Biobank, with internal testing on up to 8067 images. External testing was conducted on 7043 images from the Singapore Prospective Study and 5539 images from the Beijing Eye Study. Retinal images and corresponding refractive error data were extracted.

Methods: This retrospective study developed regression-based models, including ResNet34 with DIR, and SwinV2 (Swin Transformer) with DIR, incorporating Label Distribution Smoothing and Feature Distribution Smoothing. These models were compared against their baseline versions, ResNet34 and SwinV2, in predicting spherical and spherical equivalent (SE) power.

Main Outcome Measures: Mean absolute error (MAE) and coefficient of determination were used to evaluate the models' performances. The Wilcoxon signed-rank test was performed to assess statistical significance between DIR-integrated models and their baseline versions.

Results: For prediction of the spherical power, ResNet34 with DIR (MAE: 0.84D) and SwinV2 with DIR (MAE: 0.77D) significantly outperformed their baseline-ResNet34 (MAE: 0.88D;  < 0.001) and SwinV2 (MAE: 0.87D;  < 0.001) in internal test. For prediction of the SE power, ResNet34 with DIR (MAE: 0.78D) and SwinV2 with DIR (MAE: 0.75D) consistently significantly outperformed its baseline-ResNet34 (MAE: 0.81D;  < 0.001) and SwinV2 (MAE: 0.78D;  < 0.05) in internal test. Similar trends were observed in external test sets for both spherical and SE power prediction.

Conclusions: Deep imbalanced regressed-integrated DL models showed potential in addressing data imbalances and improving the prediction of refractive error. These findings highlight the potential utility of combining DL models with retinal imaging for opportunistic screening of refractive errors, particularly in settings where retinal cameras are already in use.

Financial Disclosures: Proprietary or commercial disclosure may be found in the Footnotes and Disclosures at the end of this article.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11808727PMC
http://dx.doi.org/10.1016/j.xops.2024.100659DOI Listing

Publication Analysis

Top Keywords

refractive error
16
deep imbalanced
8
imbalanced regression
8
error retinal
8
predict refractive
8
images singapore
8
resnet34 dir
8
distribution smoothing
8
dir mae
8
images
6

Similar Publications

Novel Grm6 Variant in a no b-wave (nob) Mouse Model: Phenotype Characterization and Gene Therapy.

Invest Ophthalmol Vis Sci

September 2025

Department of Ophthalmology, Edward S. Harkness Eye Institute, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, Columbia University, New York, New York, United States.

Purpose: To characterize a no b-wave (nob) mouse model of congenital stationary night blindness (CSNB) caused by a Grm6 variant that disrupts photoreceptor-to-bipolar cell signaling. Additionally, we aim to evaluate the efficacy of gene therapy in restoring visual function.

Methods: The nob mouse was generated through selective breeding to regenerate the nob phenotype.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the focal relationship between choroidal thickness and retinal sensitivity in myopic eyes.

Methods: Participants underwent swept-source optical coherence tomography (SS-OCT) imaging and microperimetry testing. Choroidal thicknesses were obtained by segmenting the SS-OCT scans using a deep-learning approach.

View Article and Find Full Text PDF

Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).

Methods: Case report and literature review.

Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.

View Article and Find Full Text PDF

Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.

Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.

View Article and Find Full Text PDF

Purpose: To evaluate axis-dependent visual and refractive outcomes of small incision lenticule extraction (SMILE) in patients with interocular astigmatic axis discordance.

Methods: Seventy-five patients (150 eyes) with interocular astigmatic axis discordance were included in the study. Based on interocular axis combinations, patients were stratified into three cohorts: with-the-rule (WTR)/against-the-rule (ATR) (n = 19), WTR/oblique astigmatism (OA) (n = 39), and ATR/OA (n = 17).

View Article and Find Full Text PDF