98%
921
2 minutes
20
Background: 7-Hydroxymethotrexate (7-OHMTX) is the main metabolite in plasma following high-dose MTX (HD-MTX), which may result in activity and toxicity of the MTX. Moreover, 7-OHMTX could produce crystalline-like deposits within the renal tubules under acidic conditions or induce renal inflammation, oxidative stress, and cell apoptosis through various signaling pathways, ultimately leading to kidney damage. The objectives of this study were thus to explore the exposure-safety relationship of two compounds and search the most reliable marker for predicting HDMTX nephrotoxicity.
Method: A total of 280 plasma concentration data (140 for MTX and 140 for 7-OHMTX) for 60 pediatric patients with non-Hodgkin lymphoma (NHL) were prospectively collected. Plasma MTX and 7-OHMTX concentrations were determined using a high-performance liquid chromatography tandem mass spectrometry (HPLC-MS/MS) method. A nonlinear mixed effect model approach was used to build a joint population pharmacokinetic (PopPK) model. After validation, the model estimated the peak concentration (C) and area under the curve within the initial 48 h (AUC) of the patients after drug administration by Bayesian feedback. The receiver operating characteristic (ROC) curves were generated to identify an exposure threshold associated with nephrotoxicity.
Results: A three-compartment chain model (central and peripheral compartments for MTX and central compartment 7-OHMTX) with the first-order elimination adequately characterized the in vivo process of MTX and 7-OHMTX. The covariate analysis identified that the aspartate aminotransferase (AST) was strongly associated with the peripheral volume of distribution of MTX. Moreover, the C of MTX and 7-OHMTX showed significant differences (p < 0.0001, p = 0.0472, respectively) among patients with or without nephrotoxicity. Similarly, individuals with nephrotoxicity also exhibited substantially higher ratio of 7-OHMTX to MTX peak concentration and the sum of MTX + 2.25 times the concentration of 7-OHMTX (p < 0.0001, p = 0.0426, respectively). By ROC analysis, the C of MTX and 7-OHMTX had the greatest area under the curve (AUC) values (0.769 and 0.771, respectively). A C threshold of 9.26 μmol/L for MTX or a C threshold of 0.66 μmol/L for 7-OHMTX was associated with the best sensitivity/specificity for toxicity events (MTX: sensitivity = 0.886; specificity = 0.70; 7-OHMTX: sensitivity = 0.886; specificity = 0.70).
Conclusions: We demonstrated that the C of MTX and 7-OHMTX were the most reliable markers associated with nephrotoxicity and proposed a C threshold of 9.26 μmol/L for MTX and 0.66 μmol/L for 7-OHMTX as the point with a high risk of nephrotoxicity. Altogether, this study may contribute to crucial insights for ensuring the safe administration of drugs in pediatric clinical practice.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11739129 | PMC |
http://dx.doi.org/10.1002/cam4.70516 | DOI Listing |
J Pharm Biomed Anal
August 2025
Department of Laboratory Medicine, The First Hospital of Jilin University, 1 Xinmin Street, Changchun, Jilin Province 130061, China. Electronic address:
High-dose methotrexate (HDMTX) is widely accepted as the first-line chemotherapeutic agent for pediatric acute lymphoblastic leukemia (ALL). However, it exhibits significant pharmacokinetic variability among individuals, which may lead to delayed elimination of MTX. In this study, we innovatively developed a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the simultaneous quantification of serum MTX, 7-hydroxymethotrexate (7-OHMTX) and creatinine.
View Article and Find Full Text PDFCancer Med
January 2025
Clinical Research Center, Beijing Children's Hospital, Capital Medical University, Beijing, China.
Background: 7-Hydroxymethotrexate (7-OHMTX) is the main metabolite in plasma following high-dose MTX (HD-MTX), which may result in activity and toxicity of the MTX. Moreover, 7-OHMTX could produce crystalline-like deposits within the renal tubules under acidic conditions or induce renal inflammation, oxidative stress, and cell apoptosis through various signaling pathways, ultimately leading to kidney damage. The objectives of this study were thus to explore the exposure-safety relationship of two compounds and search the most reliable marker for predicting HDMTX nephrotoxicity.
View Article and Find Full Text PDFZhonghua Yi Xue Za Zhi
July 2020
Beijing Hospital, National Center of Gerontology, National Center for Clinical Laboratories, Graduate School of Peking Union Medical College, Beijing 100730, China.
To discuss the application value of the simultaneous determination of methotrexate (MTX) and 7-hydroxymethotrexate (7-OHMTX) in the delayed elimination of MTX for pediatric acute lymphoblastic leukemia (ALL). Cross sectional study. A total of 97 children who received 192 high-dose MTX treatments cycles in Lu Daopei Hospital from April to August 2019 were enrolled.
View Article and Find Full Text PDFTher Drug Monit
February 2018
INSERM U911-CRO2 SMARTc, Aix-Marseille Univ, Marseille, France.
Background: The aim of this study was to investigate the correlation between 7-hydroxymethotrexate (7-OHMTX) and creatinine and to evaluate the predictive value of 7-OHMTX levels on delayed elimination at 24 and 48 hours. In addition, differences in methotrexate (MTX), 7-OHMTX levels, and MTX metabolism using the ratio MTX/7-OHMTX were determined according to age.
Methods: The authors included a total of 106 cycles, corresponding to 33 patients (mean age: 9.
J Liq Chromatogr Relat Technol
October 2016
Department of Pharmaceutical Sciences, St. Jude Children's Research Hospital, Memphis, TN 38105, USA.
A rapid and robust method for measuring methotrexate (MTX) and its two primary metabolites, 7-hydroxymethotrexate (7-OHMTX) and 2,4-diamino-N-methylpteroic acid (DAMPA), was developed for use in pharmacokinetic studies of plasma and cerebrospinal fluid samples collected from infants with malignant brain tumors. Sample aliquots (100μL) were prepared for bioanalysis of MTX and metabolites using a Waters Oasis HLB microelution SPE plate. Chromatography was performed using a Phenomenex Synergi Polar-RP 4μ 75 × 2.
View Article and Find Full Text PDF