Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Refractive errors are a common global health issue. Previous studies in Cameroon have predominantly identified hyperopia and hyperopic astigmatism as the primary refractive errors. This study aimed to determine ocular axial length (OAL) values in Cameroonian adults and to evaluate differences between genders and refractive error groups.

Methods: A cross-sectional study was conducted at the ophthalmology unit of Yaoundé Central Hospital. Participants aged 20-40 years who consented and had no intraocular pathologies or craniofacial malformations were included. OAL was measured using A-scan ultrasonography, and objective refraction was performed following cycloplegia. Age, gender, and refractive error were recorded. Statistical analyses, including Student's t-test, ANOVA, Chi-square, and Pearson correlation coefficient were used with a significance level of p < 0.05.

Results: A total of 200 participants, predominantly female (75.5%), were included. The mean age was 26.36 ± 5.01 years. Men had significantly longer OAL (24.01 ± 0.88 mm) compared to women (23.47 ± 0.84 mm) (adjusted p-value = 0.00). While OAL was slightly larger in myopes and shorter in hypermetropes, these differences were not statistically significant. However, OAL increased significantly with increasing myopia severity (p = 0.000) and decreased with increasing hyperopia severity (p = 0.000). There was a negative, moderate, and significant correlation between OAL and spherical value (r = -0.432 for the right eye, r = -0.429 for the left eye, adjusted p = 0.01).

Conclusion: The OAL values observed in our population were higher than those reported in other studies, and a significant gender difference was noted. These findings suggest that factors other than OAL, such as ocular optics, may significantly influence the hyperopic status of our population.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11735051PMC
http://dx.doi.org/10.7759/cureus.75828DOI Listing

Publication Analysis

Top Keywords

refractive error
12
ocular axial
8
axial length
8
genders refractive
8
cross-sectional study
8
yaoundé central
8
central hospital
8
refractive errors
8
oal
8
oal values
8

Similar Publications

Novel Grm6 Variant in a no b-wave (nob) Mouse Model: Phenotype Characterization and Gene Therapy.

Invest Ophthalmol Vis Sci

September 2025

Department of Ophthalmology, Edward S. Harkness Eye Institute, Vagelos College of Physicians and Surgeons, Columbia University Irving Medical Center, Columbia University, New York, New York, United States.

Purpose: To characterize a no b-wave (nob) mouse model of congenital stationary night blindness (CSNB) caused by a Grm6 variant that disrupts photoreceptor-to-bipolar cell signaling. Additionally, we aim to evaluate the efficacy of gene therapy in restoring visual function.

Methods: The nob mouse was generated through selective breeding to regenerate the nob phenotype.

View Article and Find Full Text PDF

Purpose: The purpose of this study was to investigate the focal relationship between choroidal thickness and retinal sensitivity in myopic eyes.

Methods: Participants underwent swept-source optical coherence tomography (SS-OCT) imaging and microperimetry testing. Choroidal thicknesses were obtained by segmenting the SS-OCT scans using a deep-learning approach.

View Article and Find Full Text PDF

Purpose: To report a case of acute and transient accommodative insufficiency after laser in situ keratomileusis (LASIK) due to coronavirus disease 2019 (COVID-19).

Methods: Case report and literature review.

Results: A 36-year-old man complained of acute blurred near vision 7 days after uneventful bilateral hyperopic LASIK, concurrent with the onset of COVID-19 infection.

View Article and Find Full Text PDF

Purpose: To analyze the effects of ablation interruption on ablation depths and clinical refractive outcomes to characterize the impact of ambient temperature changes and ablation interruption on ocular surface temperature (OST) during excimer laser ablation.

Methods: This prospective study was conducted on laser ablations in polymethylmethacrylate (PMMA) plates and porcine corneas to simulate laser in situ keratomileusis (LASIK) treatments using the EX500 laser (Alcon Laboratories, Inc) at ambient temperatures of 18, 20, and 22 °C. Ablation interruption was performed for 1, 2, 3, 4, and 5 seconds at the 10th second of the treatment of -9.

View Article and Find Full Text PDF

Purpose: To evaluate axis-dependent visual and refractive outcomes of small incision lenticule extraction (SMILE) in patients with interocular astigmatic axis discordance.

Methods: Seventy-five patients (150 eyes) with interocular astigmatic axis discordance were included in the study. Based on interocular axis combinations, patients were stratified into three cohorts: with-the-rule (WTR)/against-the-rule (ATR) (n = 19), WTR/oblique astigmatism (OA) (n = 39), and ATR/OA (n = 17).

View Article and Find Full Text PDF