98%
921
2 minutes
20
Chinese local pig breeds have unique meat flavor. In this study, we investigated the meat quality traits and the characteristics of the nutritional flavor substances such as amino acids (AAs), fatty acids (FAs), thiamine (Vitamin B1, VB1), and inosine monophosphate (IMP) in four Shanghai local pig breeds (MMS, SW, PD, and SHW) and the commercial crossbred Duroc × Landrace × Yorkshire (DLY) breed. The results showed that the intramuscular fat (IMF) and protein content in the longissimus dorsi muscle (L) of Shanghai local breeds, especially Shanghai MMS and PD breeds, were significantly higher than those of the DLY breed (-value < 0.01). The inter-breed differences in amino acid (AA) content were even more significant in the gluteal muscle (G). Total amino acids (TAAs), flavor amino acids (FAAs), and essential amino acids (EAAs) were significantly higher in the G muscle of the four Shanghai local breeds than that in the DLY breed. The results for fatty acids (FAs) revealed that the differences in polyunsaturated fatty acids (PUFAs) were all highly significant (-value < 0.0001), especially for the MMS breed, where the content of PUFAs in the L and G muscle amounted to (14.86 ± 2.06) g/100 g and (14.64 ± 2.83) g/100 g, respectively, which were significantly higher than those of other breeds. The MMS breed was also found to have the highest IMP content and the lowest thiamine (VB1) content among several pig breeds. Therefore, these differences in meat nutritional flavor substances provide new insights into the characterization of meat flavor in Shanghai local pig breeds.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11720161 | PMC |
http://dx.doi.org/10.3390/foods14010063 | DOI Listing |
J Synchrotron Radiat
November 2025
State Key Laboratory of Chemical Reaction Dynamics, Dalian Institute of Chemical Physics, Chinese Academy of Sciences, Dalian 116023, People's Republic of China.
This study develops an integrated X-ray absorption spectroscopy (XAS) photoemission electron microscopy (PEEM) platform on beamline BL09U at the Shanghai Synchrotron Radiation Facility (SSRF), enabling nanoscale characterization of complex materials through energy-resolved imaging and local-area XAS. By using the wide range of energy tunability, full access to different polarizations and PEEM's surface sensitivity, we have established a gap-monochromator control system under the EPICS framework to synchronize the elliptically polarized undulator (EPU) gap and monochromator energy dynamically, optimizing photon flux stability for absorption fine structure analysis. Combining X-ray magnetic circular dichroism (XMCD) and X-ray magnetic linear dichroism (XMLD) with PEEM and local-area XAS, this platform achieves concurrent mapping of electronic structures and magnetic domains in ferromagnetic nano-patterns, as demonstrated through our studies of NiFe Permalloy using this system.
View Article and Find Full Text PDFInt J Surg
September 2025
Department of Interventional Ultrasound, Fifth Medical Center of Chinese PLA General Hospital, Beijing, China.
Sonazoid, a combined blood pool and Kupffer-cell agent, can be specifically phagocytosed by Kupffer cells in the liver, allowing lesion detection and characterization of focal liver lesions (FLLs) at the post-vascular phase apart from the vascular phase which is similar to that of other second-generation US contrast agents. Sonazoid CEUS is currently approved for use in some Asian countries. With the increasing use of Sonazoid CEUS for FLLs in clinical practice, developing consensus or guidelines to help standardize its use is required.
View Article and Find Full Text PDFInt J Surg
September 2025
Department of Thoracic Surgery, Shanghai Pulmonary Hospital, School of Medicine, Tongji University, Shanghai, China.
Background: Phrenic nerve injury during mediastinal tumor resection can lead to significant postoperative diaphragmatic dysfunction. Current intraoperative protection techniques are imprecise and lack real-time feedback. We aimed to develop and validate a quantifiable, multimodal neuroprotective strategy.
View Article and Find Full Text PDFRadiol Artif Intell
September 2025
Department of Radiology, Shanghai Jiao Tong University Medical School Affiliated Ruijin Hospital, No. 197 Ruijin Er Road, Shanghai 200025, China.
Purpose To assess the effectiveness of an explainable deep learning (DL) model, developed using multiparametric MRI (mpMRI) features, in improving diagnostic accuracy and efficiency of radiologists for classification of focal liver lesions (FLLs). Materials and Methods FLLs ≥ 1 cm in diameter at mpMRI were included in the study. nn-Unet and Liver Imaging Feature Transformer (LIFT) models were developed using retrospective data from one hospital (January 2018-August 2023).
View Article and Find Full Text PDFJ Magn Reson Imaging
September 2025
Department of Radiology, Huashan Hospital, Fudan University, Shanghai, China.
Background: Parkinson's disease (PD) often presents with lateralized motor symptoms at onset, reflecting asymmetric degeneration of the substantia nigra (SN). Neuromelanin (NM) loss and iron accumulation are hallmarks of SN pathology in PD, but their spatial distribution and interrelationship in PD patients with right-sided (PDR) or left-sided (PDL) motor symptom onset remain unclear.
Purpose: To investigate the spatial vulnerability and interrelationship of NM and iron in the SN among PDR, PDL, and healthy controls (HCs) using MRI.