Article Abstract

Purpose: Cardiac radioablation is a novel, non-invasive treatment for ventricular tachycardia (VT), involving a single fractional stereotactic ablative body radiotherapy (SABR) session with a prescribed dose of 25 Gy. This complex procedure requires a detailed workflow and stringent dose constraints compared to conventional radiation therapy. This study aims to establish a consistent institutional workflow for single-fraction cardiac VT-SABR, emphasizing robust plan evaluation and quality assurance.

Materials And Methods: The study developed a consistent institutional workflow for VT-SABR, including computed tomography (CT) simulation, target volume definition, treatment planning, robust plan evaluation, quality assurance, and image-guided strategy. The workflow was implemented for two patients with cardiac arrhythmia. Accurate target volume definition using planning CT images and electronic anatomical mapping was critical. A four-dimensional (4D) cone-beam CT (CBCT) and breath-hold electrocardiographic gated CT images reliably detected target motion.

Results: The resulting plans exhibited a conformity index greater than 0.7 and a gradient index around G4.0. Dose constraints for the planning target volume (PTV) aimed for 95% or higher PTV dose coverage, with a maximum dose of 200% or lower. However, one case did not meet the PTV dose coverage due to the proximity of the PTV to gastrointestinal organs. Plans adhered to dose constraints for organs at risk near the heart, but meeting constraints for specific cardiac sub-structures was challenging and dependent on PTV location.

Conclusion: The plans demonstrated robustness against respiratory motion and patient positional uncertainty through a robust evaluation function. The 4D and intra-fractional CBCT were effective in verifying target motion and setup stability.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11701467PMC
http://dx.doi.org/10.3857/roj.2024.00262DOI Listing

Publication Analysis

Top Keywords

dose constraints
12
target volume
12
stereotactic ablative
8
ablative body
8
body radiotherapy
8
ventricular tachycardia
8
consistent institutional
8
institutional workflow
8
robust plan
8
plan evaluation
8

Similar Publications

Background: High-dose-rate (HDR) brachytherapy is essential in the treatment of locally advanced cervical cancer. While Iridium-192 (Ir-192) is commonly used, its short half-life imposes logistical and financial constraints, particularly in low- and middle-income countries (LMICs). Cobalt-60 (Co-60), with a longer half-life and lower operational costs, is a viable alternative.

View Article and Find Full Text PDF

Background: Stereotactic Body Radiotherapy (SBRT) has been proven to be a safe and effective alternative to surgery in patients with metastatic primary sarcoma. However, data describing tumor response in relation to the given radiotherapy dose is lacking. Therefore, this study aims at analyzing efficacy and dose-response relationship in a retrospective cohort.

View Article and Find Full Text PDF

Objective: To assess the knowledge and practices of community pharmacists regarding managing diabetes in fasting patients during Ramadan and the barriers the community pharmacists face when managing diabetic patients who fast in Ramadan.

Design: A survey-based cross-sectional study.

Setting: A structured questionnaire was distributed online during April and May 2024.

View Article and Find Full Text PDF

Purpose: Esophageal RV25 < 20 % and AV35 < 0.27 mL were reported as dose constraints predictive of grade ≥ 2 radiation esophagitis (RE) for breast cancer in our previous study. This prospective study aimed to validate the effectiveness of esophageal dose constraints and develop RE prediction models.

View Article and Find Full Text PDF

Current antithrombotic therapies face dual constraints of bleeding complications and monitoring requirements. Although natural hirudin provides targeted thrombin inhibition, its clinical adoption is hindered by sourcing limitations. This study developed a recombinant hirudin variant HMg (rHMg) with enhanced anticoagulant activity through genetic engineering and established cost-effective large-scale production methods.

View Article and Find Full Text PDF