Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

We assessed the effect of beam size on plan robustness for intensity-modulated proton therapy (IMPT) of head and neck cancer (HNC) and compared the plan quality including robustness with that of intensity-modulated radiation therapy (IMRT). IMPT plans were generated for six HNC patients using six beam sizes (air-sigma 3-17 mm at isocenter for a 70-230 MeV) and two optimization methods for planning target volume-based non-robust optimization (NRO) and clinical target volume (CTV)-based robust optimization (RO). Worst-case dosimetric parameters and plan robustness for CTV and organs-at-risk (OARs) were assessed under different scenarios, assuming a ± 1-5 mm setup error and a ± 3% range error. Statistical comparisons of NRO-IMPT, RO-IMPT and IMRT plans were performed. In regard to CTV-D99%, RO-IMPT with smaller beam size was more robust than RO-IMPT with larger beam sizes, whereas NRO-IMPT showed the opposite (P < 0.05). There was no significant difference in the robustness of the CTV-D99% and CTV-D95% between RO-IMPT and IMRT. The worst-case CTV coverage of IMRT (±5 mm/3%) for all patients was 96.0% ± 1.4% (D99%) and 97.9% ± 0.3% (D95%). For four out of six patients, the worst-case CTV-D95% for RO-IMPT (±1-5 mm/3%) were higher than those for IMRT. Compared with IMRT, RO-IMPT with smaller beam sizes achieved lower worst-case doses to OARs. In HNC treatment, utilizing smaller beam sizes in RO-IMPT improves plan robustness compared to larger beam sizes, achieving comparable target robustness and lower worst-case OARs doses compared to IMRT.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11753836PMC
http://dx.doi.org/10.1093/jrr/rrae097DOI Listing

Publication Analysis

Top Keywords

beam size
12
intensity-modulated proton
8
proton therapy
8
robust optimization
8
head neck
8
intensity-modulated radiation
8
radiation therapy
8
plan robustness
8
robustness intensity-modulated
8
beam sizes
8

Similar Publications

Background And Aim: The incisive (nasopalatine) canal is an important anatomical structure of the anterior maxilla. It holds significance for surgeries and implant placement in the central incisor region. The size, shape, and relation with surrounding bones may vary by age, gender, and ethnicity.

View Article and Find Full Text PDF

Purpose: To compare the accuracy of static guided surgery using a pilot drill guide and dynamic guided surgery for dental implant placement.

Materials And Methods: Partially edentulous adult patients requiring implant placement were randomly assigned to either the static guided surgery group using a pilot drill guide or the dynamic guided surgery group. Digital implant planning was conducted using intraoral scans and CBCT with planning software to determine the optimal prosthetic position.

View Article and Find Full Text PDF

Small cell neuroendocrine carcinoma of the cervix is an uncommon, aggressive tumor that most often affects women in their 40s and is frequently linked to high-risk human papillomavirus (HPV) infection. It is associated with poor prognosis even in early-stage disease. We report the case of a 36-year-old woman with high-risk HPV who presented with abnormal vaginal bleeding.

View Article and Find Full Text PDF

Electrochemiluminescence (ECL) imaging through closed bipolar nanoelectrode arrays (BPnEAs) has emerged as a promising method for in situ label-free wide-field electrochemical imaging. In this study, a cathodic ECL system based on [Ru(bpz)]/SO is combined with the BPnEAs fabricated on silicon nitride membrane windows through focused ion beam nanofabrication, enabling effective bipolar imaging of heterogeneous anodic electrocatalytic reactions. The shape, distribution, size, and material composition of individual electrodes within the array can be precisely controlled.

View Article and Find Full Text PDF

On-site and accurately detecting, sizing and counting living algae are greatly needed under International Ballast Water Convention, yet still challenging due to the lack of miniatured device. In this paper, a miniatured microscope that has both blue view field and fluorescence field was developed. Dual-view-field with one exciting light is achieved by using a beam splitter to direct the light into two mini cameras.

View Article and Find Full Text PDF