98%
921
2 minutes
20
Ammonium level in body fluids serves as one of the critical biomarkers for healthcare, especially those relative to liver diseases. The continuous and real-time monitoring in both invasive and non-invasive manners is highly desired, while the ammonium concentrations vary largely in different body fluids. Besides, the sensing reliability based on ion-selective biosensors can be significantly interfered by potassium ions. To tackle these challenges, a flexible and biocompatible sensing patch for wireless ammonium level sensing was reported with an ultrawide linear range for universal body fluids including blood, tears, saliva, sweat and urine. The as-prepared biocompatible sensors deliver a reliable sensitivity of 58.7 mV decade in the range of 1-100 mM and a desirable selectivity coefficient of 0.11 in the interference of potassium ions, attributed to the cross-calibration within the sensors array. The sensor's biocompatibility was validated by the cell growth on the sensor surface (> 80%), hemolysis rates (< 5%), negligible cellular inflammatory responses and weight changes of the mice with implanted sensors. Such biocompatible sensors with ultrawide linear range and desirable selectivity open up new possibility of highly compatible biomarker analysis via different body fluids in versatile approaches.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11663834 | PMC |
http://dx.doi.org/10.1007/s40820-024-01602-2 | DOI Listing |
Methods Cell Biol
September 2025
Department of Radiation Oncology, Weill Cornell Medicine, New York, NY, United States. Electronic address:
Mesentery is a crucial part of an animal's digestive system since it holds the intestine in place, while also contains the specialized lymph nodes and immune cells that help protect the intestines from infections and support the body's immune response in the abdominal cavity. Analyzing mesenteric lymph can help better understand the transport mechanisms and potential implications for various conditions, such as lymphatic disorders or underlying infections. The first step towards this is the precise collection of the mesenteric lymph.
View Article and Find Full Text PDFInt J Biol Macromol
September 2025
Henan Key Laboratory of Materials on Deep-Earth Engineering, School of Materials Science and Engineering, Henan Polytechnic University, Jiaozuo, China. Electronic address:
A novel biodegradable bone cement (PSM) was successfully developed through the modification of magnesium oxychloride cement (MOC) with pectin, specifically addressing the inherent limitation of poor water resistance in conventional MOC. Properties of PSM such as washout resistance, setting time, mechanical properties and degradation properties were investigated. Results showed that PSM with 1.
View Article and Find Full Text PDFNMR Biomed
October 2025
Department of Radiology, University of California, San Diego, California, USA.
Myelin and myelin water (MW) behavior is becoming increasingly relevant in their role in neurodegenerative diseases. Myelin proton fraction (MPF) and myelin water fraction (MWF) measured with short-TR adiabatic inversion-recovery (STAIR) sequences are potential biomarkers of myelin and MW, respectively, but their repeatabilities are unknown. This study aims to evaluate the repeatability of MPF and MWF measured with the STAIR ultrashort echo time (STAIR-UTE) and STAIR short echo time (STAIR-STE) sequences, respectively.
View Article and Find Full Text PDFLeg Med (Tokyo)
August 2025
Department of Legal Medicine, Hamamatsu University School of Medicine, 1-20-1 Handayama, Hamamatsu 431-3192, Japan.
Reports on the quantification of fluvoxamine (FLV) in human tissues have been quite limited, although FLV has been used as an antidepressant since 1986. Fluvoxamine acid (FLA) was shown to be the major metabolite of FLV in human urine in 1983, but its quantification is also limited to only three works using human plasma. The existence of desmethyl fluvoxamine (FLD) in human specimens was recently reported in 2025; therefore, its quantification has not yet been performed.
View Article and Find Full Text PDFSud Med Ekspert
September 2025
Bureau of Forensic Medical Examination, Ufa, Russia.
Objective: To study the electrical conductivity of the knee joints' synovial fluid of human's corpse for assessment of the possibility of its application as criterion of forensic medical diagnosis of postmortem interval.
Material And Methods: The work was carried out on practical forensic medical material on the basis of the Bureau of Forensic Medical Expertise in the Republic of Bashkortostan. During the study, 103 corpses of both sexes, different ages who died from various causes were investigated.