Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Electrical stimulation can be used in several applications such as fatigue reduction, muscle rehabilitation, neurorehabilitation, neuro-prosthesis and pain relief. Moreover, electrical stimulation can be used for drug delivery applications or body fluids extraction (e.g., sweat and interstitial fluid) to successively monitor several parameters, such as glucose, lactate, etc. All these applications are performed using electrical stimulator devices capable of applying constant voltage pulses or constant current pulses via electrodes to human tissues. Usually, constant current stimulators are most widely used because of their safety, stability, and repeatability. Thus, the aim of this work was to design, realize and test a mixed-signal electronic interface capable of producing current pulses with custom amplitude, duration, frequency, polarity and symmetry with extended voltage compliance. To achieve this result, we developed a high-voltage current stimulator suitable for iontophoresis applications. Current stimuli can be applied setting the intensity, frequency and duty cycle of the stimulation patterns through a µC. A custom electronic interface was designed to allow the control of the injected current in real time and to prevent electrical injuries to the patient by avoiding potential unwanted short circuits. Moreover, the system was tested in a simulated environment demonstrating its effectiveness and applicability for transdermal monitoring applications. The obtained results show that the device is able to apply monophasic and biphasic pulses, ranging from 0.1 to 10 mA, with a maximum error of about 10% at the minimum intensity; in addition, current stimuli can be applied up to a maximum frequency of 100 kHz with a voltage compliance of 120 V.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11645059PMC
http://dx.doi.org/10.3390/s24237626DOI Listing

Publication Analysis

Top Keywords

electrical stimulation
12
electronic interface
12
transdermal monitoring
8
monitoring applications
8
mixed-signal electronic
8
constant current
8
current pulses
8
voltage compliance
8
current stimuli
8
stimuli applied
8

Similar Publications

Electrically Conductive Hydrogels for Wound Healing.

Adv Wound Care (New Rochelle)

September 2025

Beijing Laboratory of Biomedical Materials, State Key Laboratory of Organic-Inorganic Composites, Beijing University of Chemical Technology, Beijing, PR China.

Wound healing is a complex, tightly regulated process involving a range of enzymes, growth factors, and cytokines that coordinate cellular activities essential for tissue repair and wound closure. However, in cases of extensive or severe injury, the intrinsic repair mechanisms are often insufficient, underscoring the need for advanced therapeutic strategies to accelerate healing and minimize scar formation. Electrically conductive hydrogels (ECHs), combining the advantageous properties of hydrogels with the physiological and electrochemical characteristics of conductive materials, present a safer and more convenient alternative to traditional electrode-based electrical stimulation (ES) for treating chronic and nonhealing wounds.

View Article and Find Full Text PDF

Chargeable Hydrogels with Dual Modulatory Effects of Bacterial Killing and Immune Remodeling toward Wound Healing.

ACS Appl Mater Interfaces

September 2025

State Key Laboratory of Cardiovascular Diseases and Medical Innovation Center, Shanghai East Hospital, School of Medicine, Tongji University, Shanghai 200070, China.

Wound infections challenge clinical medicine, and developing novel therapies is critically important in overcoming antimicrobial resistance and an off-balanced immune microenvironment. Electrical stimulation as a biocompatible, easy-to-operate, and controllable technique has great potential in eradicating pathogens and modulating the immune system. However, safe and soft platforms that integrate both bactericidal and immunological modulatory effects of electrical stimulation are rarely reported.

View Article and Find Full Text PDF

Background: Charcot foot is a debilitating complication of peripheral neuropathy and is primarily associated with diabetes, leading to structural damage, ulceration, and osteomyelitis. Pulsed electromagnetic field (PEMF) therapy is a promising treatment modality for wound healing and bone metabolism.

Objective: To evaluate the efficacy of PEMF therapy in promoting bone growth and ulcer healing in patients with Charcot foot ulcers.

View Article and Find Full Text PDF

Correlated spiking has been widely found in large population of neurons and been linked to neural coding. Transcranial alternating current stimulation (tACS) is a promising non-invasive brain stimulation technique that can modulate the spiking activity of neurons. Despite its growing application, the tACS effects on the temporal correlation between spike trains are still not fully understood.

View Article and Find Full Text PDF

Background: Electronic nicotine delivery systems (ENDS) utilize "E-liquids" in order to generate "E-vapor", an inhalable aerosolized mixture containing nicotine and flavors. Flavored ENDS are very popular among teens who vape, however, the possible cardiac electrophysiological harm of inhalation exposure to flavored ENDS are not fully understood.

Objective: To test if inhalation exposure to flavoring carbonyls in e-liquids compromises mitochondrial integrity, increases oxidative stress, and leads to cardiac electrophysiological toxicity.

View Article and Find Full Text PDF