Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Retinal stimulation (RS) allows restoring vision in blind patients, but it covers only a narrow region of the visual field. Optic nerve stimulation (ONS) has the potential to produce visual perceptions spanning the whole visual field, but it produces very irregular phosphenes. We introduced a geometrical model converting retinal and optic nerve firing rates into visual perceptions and vice versa and a method to estimate the best perceptions elicitable through an electrode configuration. We then compared in silico ONS and RS through simulated prosthetic vision of static and dynamic visual scenes. Both simulations and SPV experiments showed that it might be possible to reconstruct natural visual scenes with ONS and RS, and that ONS wide field-of-view allows the perception of more detail in dynamic scenarios than RS. Our findings suggest that ONS could represent an interesting approach for vision restoration and that our model can be used to optimize it.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11612796PMC
http://dx.doi.org/10.1016/j.isci.2024.111321DOI Listing

Publication Analysis

Top Keywords

optic nerve
12
wide field-of-view
8
visual field
8
visual perceptions
8
visual scenes
8
visual
6
ons
5
computational model
4
model design
4
design wide
4

Similar Publications

Quantification of Normative Human Choriocapillaris Measures Across the Macula.

Invest Ophthalmol Vis Sci

September 2025

Division of Biomedical Physics, Office of Science and Engineering Laboratories, Center for Devices and Radiological Health, U.S. Food and Drug Administration, Silver Spring, Maryland, United States.

Purpose: To assess macular choriocapillaris (CC) metrics in healthy volunteers (HVs) without ocular disease and demonstrate CC variations in patients with inherited retinal dystrophies (IRDs) using adaptive optics optical coherence tomography angiography (AO-OCTA).

Methods: Twenty-one HVs and three IRD patients were imaged. Macular variation in 20 HVs in CC metrics (CC density, CC diameter, CC tortuosity, void diameter, void area, lobule count, lobule area, and RPE-CC distance) were assessed by imaging a 28° strip of overlapping AO-OCTA volumes (3° × 3°) from the optic nerve head to the temporal macula.

View Article and Find Full Text PDF

This systematic review examines the potential association between semaglutide, a glucagon-like peptide-1 (GLP-1) receptor agonist, and the development of non-arteritic anterior ischemic optic neuropathy (NAION). Nine studies were included, consisting of retrospective cohort analyses, case series, and pharmacovigilance reports. Findings across the literature were inconsistent, with some studies reporting an increased risk while others found no significant association.

View Article and Find Full Text PDF

Background Increased intracranial pressure (ICP) can be reliably detected at the bedside using the optic nerve sheath diameter (ONSD). The functional outcome in stroke patients can be predicted with the use of acute-phase ONSD dynamics. Objectives To determine the predictive accuracy of ONSD on days 0, one, and three for the prognosis of ischemic stroke patients presented to emergency medicine as measured by Modified Rankin Scale (mRS) score.

View Article and Find Full Text PDF

ROSAH (retinal dystrophy, optic nerve edema, splenomegaly, anhidrosis, and headache) syndrome is a rare genetic disease caused by variants in alpha-kinase 1 (ALPK1) resulting in downstream pro-inflammatory signaling mediated by the TIFA/TRAF6/NF-κB pathway. Here, we report the design of an ALPK1 inhibitor, DF-003, with pharmacokinetic properties suitable for daily oral dosing. In biochemical assays, DF-003 potently inhibits human ALPK1 (IC = 1.

View Article and Find Full Text PDF

Purpose: During endoscopic endonasal access to small intraconal masses deep in the orbital apex, a line of fusion between inferior and medial recti is encountered distal to the termination of the common tendinous ring. The intraoperatively viewed length of this segment has not been quantified. To assist clinical recognition of this structure, our study quantifies its length and proposes the standardized nomenclature term of inferomedial extraocular muscle raphe (IM-EOMR).

View Article and Find Full Text PDF