Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Precise lower limb measurements are crucial for assessing musculoskeletal health; fully automated solutions have the potential to enhance standardization and reproducibility of these measurements. This study compared the measurements performed by BoneMetrics (Gleamer, Paris, France), a commercial artificial intelligence (AI)-based software, to expert manual measurements on anteroposterior full-leg standing radiographs.

Methods: A retrospective analysis was conducted on a dataset comprising consecutive anteroposterior full-leg standing radiographs obtained from four imaging institutions. Key anatomical landmarks to define the hip-knee-ankle angle, pelvic obliquity, leg length, femoral length, and tibial length were annotated independently by two expert musculoskeletal radiologists and served as the ground truth. The performance of the AI was compared against these reference measurements using the mean absolute error, Bland-Altman analyses, and intraclass correlation coefficients.

Results: A total of 175 anteroposterior full-leg standing radiographs from 167 patients were included in the final dataset (mean age = 49.9 ± 23.6 years old; 103 women and 64 men). Mean absolute error values were 0.30° (95% confidence interval [CI] [0.28, 0.32]) for the hip-knee-ankle angle, 0.75 mm (95% CI [0.60, 0.88]) for pelvic obliquity, 1.03 mm (95% CI [0.91,1.14]) for leg length from the top of the femoral head, 1.45 mm (95% CI [1.33, 1.60]) for leg length from the center of the femoral head, 0.95 mm (95% CI [0.85, 1.04]) for femoral length from the top of the femoral head, 1.23 mm (95% CI [1.12, 1.32]) for femoral length from the center of the femoral head, and 1.38 mm (95% CI [1.21, 1.52]) for tibial length. The Bland-Altman analyses revealed no systematic bias across all measurements. Additionally, the software exhibited excellent agreement with the gold-standard measurements with intraclass correlation coefficient (ICC) values above 0.97 for all parameters.

Conclusions: Automated measurements on anteroposterior full-leg standing radiographs offer a reliable alternative to manual assessments. The use of AI in musculoskeletal radiology has the potential to support physicians in their daily practice without compromising patient care standards.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11606017PMC
http://dx.doi.org/10.1186/s43019-024-00246-1DOI Listing

Publication Analysis

Top Keywords

full-leg standing
20
standing radiographs
16
anteroposterior full-leg
16
femoral head
16
leg length
12
femoral length
12
measurements
9
automated measurements
8
measurements anteroposterior
8
hip-knee-ankle angle
8

Similar Publications

Introduction: Introduction This study investigates the elongation patterns of native knee collateral ligaments across various coronal plane alignment phenotypes (CPAK classification), aiming to refine soft tissue balancing in Total Knee Arthroplasty (TKA).

Materials And Methods: Materials and methods In this cross-sectional study, 84 patients were analyzed prior to undergoing TKA using a computer-assisted surgery (CAS) system. CPAK types were determined using pre-operative standing full-leg radiographs.

View Article and Find Full Text PDF

Introduction/objectives: Medial open wedge high tibial osteotomy (MOW-HTO) is a standard treatment for medial compartment osteoarthritis (OA) of the knee. Its success relies on precise preoperative planning, typically using full-leg standing radiographs (FLSR) for coronal alignment assessment. However, factors like knee flexion and rotation can influence alignment measurements.

View Article and Find Full Text PDF

Background: Precise lower limb measurements are crucial for assessing musculoskeletal health; fully automated solutions have the potential to enhance standardization and reproducibility of these measurements. This study compared the measurements performed by BoneMetrics (Gleamer, Paris, France), a commercial artificial intelligence (AI)-based software, to expert manual measurements on anteroposterior full-leg standing radiographs.

Methods: A retrospective analysis was conducted on a dataset comprising consecutive anteroposterior full-leg standing radiographs obtained from four imaging institutions.

View Article and Find Full Text PDF

The Coronal Plane Alignment of the Knee (CPAK) classification is a pragmatic distribution of nine phenotypes for coronal knee alignment that can be used on healthy and arthritic knees. Our study aimed to describe the CPAK distributions in a Spanish southeast osteoarthritic population and compare them to other populations' published alignment distributions. Full-leg standing X-rays of the lower limb from 528 cases originating from the so-called Vega Alta del Segura (southeast of the Iberian Peninsula) were retrospectively analysed.

View Article and Find Full Text PDF

Objective: Lower limb discrepancy (LLD) was frequently observed in patients with idiopathic scoliosis (IS), potentially associated with etiopathogenesis. Although sole lifts had been proposed as a conservative treatment for IS, evidence supporting their efficacy was limited. This study aimed to assess the effects of sole lift intervention on pediatric patients with mild IS, specifically focusing on thoracolumbar/lumbar (TL/L) curvature.

View Article and Find Full Text PDF