98%
921
2 minutes
20
Background: Precise lower limb measurements are crucial for assessing musculoskeletal health; fully automated solutions have the potential to enhance standardization and reproducibility of these measurements. This study compared the measurements performed by BoneMetrics (Gleamer, Paris, France), a commercial artificial intelligence (AI)-based software, to expert manual measurements on anteroposterior full-leg standing radiographs.
Methods: A retrospective analysis was conducted on a dataset comprising consecutive anteroposterior full-leg standing radiographs obtained from four imaging institutions. Key anatomical landmarks to define the hip-knee-ankle angle, pelvic obliquity, leg length, femoral length, and tibial length were annotated independently by two expert musculoskeletal radiologists and served as the ground truth. The performance of the AI was compared against these reference measurements using the mean absolute error, Bland-Altman analyses, and intraclass correlation coefficients.
Results: A total of 175 anteroposterior full-leg standing radiographs from 167 patients were included in the final dataset (mean age = 49.9 ± 23.6 years old; 103 women and 64 men). Mean absolute error values were 0.30° (95% confidence interval [CI] [0.28, 0.32]) for the hip-knee-ankle angle, 0.75 mm (95% CI [0.60, 0.88]) for pelvic obliquity, 1.03 mm (95% CI [0.91,1.14]) for leg length from the top of the femoral head, 1.45 mm (95% CI [1.33, 1.60]) for leg length from the center of the femoral head, 0.95 mm (95% CI [0.85, 1.04]) for femoral length from the top of the femoral head, 1.23 mm (95% CI [1.12, 1.32]) for femoral length from the center of the femoral head, and 1.38 mm (95% CI [1.21, 1.52]) for tibial length. The Bland-Altman analyses revealed no systematic bias across all measurements. Additionally, the software exhibited excellent agreement with the gold-standard measurements with intraclass correlation coefficient (ICC) values above 0.97 for all parameters.
Conclusions: Automated measurements on anteroposterior full-leg standing radiographs offer a reliable alternative to manual assessments. The use of AI in musculoskeletal radiology has the potential to support physicians in their daily practice without compromising patient care standards.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11606017 | PMC |
http://dx.doi.org/10.1186/s43019-024-00246-1 | DOI Listing |
Arch Orthop Trauma Surg
July 2025
ZAS Cadix Antwerpen, Antwerp, Belgium.
Introduction: Introduction This study investigates the elongation patterns of native knee collateral ligaments across various coronal plane alignment phenotypes (CPAK classification), aiming to refine soft tissue balancing in Total Knee Arthroplasty (TKA).
Materials And Methods: Materials and methods In this cross-sectional study, 84 patients were analyzed prior to undergoing TKA using a computer-assisted surgery (CAS) system. CPAK types were determined using pre-operative standing full-leg radiographs.
J ISAKOS
August 2025
Charité - Universitätsmedizin Berlin, Centrum für Muskuloskeletale Chirurgie, Berlin, Germany.
Introduction/objectives: Medial open wedge high tibial osteotomy (MOW-HTO) is a standard treatment for medial compartment osteoarthritis (OA) of the knee. Its success relies on precise preoperative planning, typically using full-leg standing radiographs (FLSR) for coronal alignment assessment. However, factors like knee flexion and rotation can influence alignment measurements.
View Article and Find Full Text PDFKnee Surg Relat Res
November 2024
Department of Radiology, Boston University School of Medicine, Boston, MA, USA.
Background: Precise lower limb measurements are crucial for assessing musculoskeletal health; fully automated solutions have the potential to enhance standardization and reproducibility of these measurements. This study compared the measurements performed by BoneMetrics (Gleamer, Paris, France), a commercial artificial intelligence (AI)-based software, to expert manual measurements on anteroposterior full-leg standing radiographs.
Methods: A retrospective analysis was conducted on a dataset comprising consecutive anteroposterior full-leg standing radiographs obtained from four imaging institutions.
Medicina (Kaunas)
October 2024
Department of Orthopaedic Surgery and Traumatology, Hospital General Universitario Reina Sofía, Avda. Intendente Jorge Palacios, 1, 30003 Murcia, Spain.
The Coronal Plane Alignment of the Knee (CPAK) classification is a pragmatic distribution of nine phenotypes for coronal knee alignment that can be used on healthy and arthritic knees. Our study aimed to describe the CPAK distributions in a Spanish southeast osteoarthritic population and compare them to other populations' published alignment distributions. Full-leg standing X-rays of the lower limb from 528 cases originating from the so-called Vega Alta del Segura (southeast of the Iberian Peninsula) were retrospectively analysed.
View Article and Find Full Text PDFOrthop Surg
November 2024
Department of Orthopedic Surgery, The Second Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou City, China.
Objective: Lower limb discrepancy (LLD) was frequently observed in patients with idiopathic scoliosis (IS), potentially associated with etiopathogenesis. Although sole lifts had been proposed as a conservative treatment for IS, evidence supporting their efficacy was limited. This study aimed to assess the effects of sole lift intervention on pediatric patients with mild IS, specifically focusing on thoracolumbar/lumbar (TL/L) curvature.
View Article and Find Full Text PDF