Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Cardiac mapping is a crucial procedure for diagnosing and treating cardiac arrhythmias. Still, current clinical techniques face limitations including insufficient electrode coverage, poor conformability to complex heart chamber geometries, and high costs. This study explores the design, testing, and validation of a 64-electrode soft robotic catheter that addresses these challenges in cardiac mapping. A dual-layer flexible printed circuit board (PCB) was designed and integrated with sensors into a soft robotic sensor array (SRSA) assembly. Design considerations included flex PCB layout, routing, integration, conformity to heart chambers, sensor placement, and catheter durability. Rigorous SRSA in vitro testing evaluated the burst/leakage pressure, block force for electrode contact, mechanical integrity, and environmental resilience. For in vivo validation, a porcine model was used to demonstrate the successful deployment, conformability, and acquisition of electrograms in both the ventricles and atria. This catheter-deployable SRSA represents a meaningful step towards translating the integration of soft robotic actuators and stretchable electronics for clinical use, showcasing the unique mechanical and electrical performance that these designs enable. The high-density electrode array enabled rapid 2 s data acquisition with detailed spatial and temporal resolution, as illustrated by the clear and consistent cardiac signals recorded across all electrodes. The future of this work will lie in enabling high-density, anatomically conformable devices for detailed cardiac mapping to guide ablation therapy and other interventions.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11596174PMC
http://dx.doi.org/10.3390/mi15111393DOI Listing

Publication Analysis

Top Keywords

soft robotic
16
cardiac mapping
12
design testing
8
testing validation
8
robotic sensor
8
sensor array
8
cardiac arrhythmias
8
cardiac
6
soft
4
validation soft
4

Similar Publications

Significance: Melanoma's rising incidence demands automatable high-throughput approaches for early detection such as total body scanners, integrated with computer-aided diagnosis. High-quality input data is necessary to improve diagnostic accuracy and reliability.

Aim: This work aims to develop a high-resolution optical skin imaging module and the software for acquiring and processing raw image data into high-resolution dermoscopic images using a focus stacking approach.

View Article and Find Full Text PDF

Aims: Psychological resilience refers to an individual's capacity to adapt to adverse events. MicroRNAs (miRNAs) play a crucial role in regulating post-transcriptional processes, while small extracellular vesicles (sEVs) act as transport vehicles. This study aimed to employ genome-wide profiling to identify and validate differences in the expression of resilience-associated sEV-miRNAs between low resilience (LR) and high resilience (HR) in young adults.

View Article and Find Full Text PDF

The development of non-Hodgkin lymphoma following liver transplant is rare. We present an unusual case of a 40-year-old female patient with morbid obesity who had undergone a deceased donor liver transplant for an unresectable neuroendocrine tumor of the liver 12 years ago. She presented with a lesion in the tail of pancreas that was suggestive of a recurrent neuroendocrine tumor.

View Article and Find Full Text PDF

This study was conducted to investigate the techniques and complications of enlarged uterine extraction during minimally invasive surgery for uterine malignancy. The electronic medical record was queried for patients with uterine malignancy and enlarged uterus (≥ 250 g) who underwent primary hysterectomy with laparoscopic or robotic approach. Statistical analysis was performed using Fisher's exact test for categorical variables and Kruskal-Wallis test for continuous variables.

View Article and Find Full Text PDF