Comparison of the outcomes between ultrasonic devices and clamping in hepatectomy: a meta-analysis.

World J Surg Oncol

Division of Liver Surgery, Department of General Surgery, West China Hospital, Sichuan University, Chengdu, China.

Published: November 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: Recent advances in ultrasound technology have led to widespread adoption of ultrasonic energy devices in liver resections. While various studies have assessed the comparative advantages of ultrasonic devices and traditional clamp-crushing, their findings vary. Moreover, a specific systematic review on this topic has not yet been conducted.

Objectives: This study aims to present a comprehensive, up-to-date analysis comparing outcomes between ultrasonic devices and conventional clamp-crushing methods in liver resection, based on currently available literature.

Patients And Methods: We conducted a systematic literature search in databases such as PubMed, Embase, Web of Science, and CNKI up to November 2023. Studies that compared the efficacy or safety of ultrasonic devices against traditional clamp-crushing methods in hepatectomy were included. The analysis covered intraoperative outcomes like operating time, blood loss, and transfusion rate, as well as postoperative outcomes such as complication rate, mortality, postoperative bleeding, and bile leakage. Review Manager version 5.3 (Cochrane Collaboration, Oxford, UK) and Stata 17.0 (Stata Corp, College Station, TX, USA) were used for data analysis.

Results: Thirteen studies, involving a total of 1,417 patients (630 using ultrasonic devices and 787 using clamp-crushing methods), were included. The clamp-crush method resulted in a shorter operation time. Contrarily, the ultrasonic device group experienced reduced blood loss and lower transfusion rates. Postoperatively, there was no significant difference in mortality or postoperative bleeding between the groups. However, the ultrasonic group had a lower overall complication rate, particularly a reduced incidence of bile leakage. Overall, the ultrasonic devices were associated with improved perioperative outcomes.

Conclusions: The findings suggest that ultrasonic devices provide better outcomes in hepatectomy compared to traditional clamp-crushing techniques. Nonetheless, large-scale randomized controlled trials are needed to confirm these results due to potential heterogeneity and biases. The choice of using ultrasonic devices should consider the surgeon's experience and individual patient circumstances.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11568570PMC
http://dx.doi.org/10.1186/s12957-024-03575-3DOI Listing

Publication Analysis

Top Keywords

ultrasonic devices
32
traditional clamp-crushing
12
clamp-crushing methods
12
ultrasonic
11
devices
9
outcomes ultrasonic
8
devices traditional
8
blood loss
8
complication rate
8
mortality postoperative
8

Similar Publications

In this study, we investigated the influence of ultrasonic frequency during ultrasound-assisted chemical bath deposition (UCBD) on the surface morphology and electrochemical performance of CoO:MnO@CoMnO composite flexible electrodes for supercapacitor applications. By systematically varying the ultrasonic frequency (1.0-2.

View Article and Find Full Text PDF

Objectives: This study aims to assess the efficacy and safety of five categories of intracorporeal lithotripsy devices in percutaneous nephrolithotomy (PCNL): Pneumatic lithotripters, ultrasonic lithotripters, double-probe dual-energy lithotripters, single-probe dual-energy (SPDE) lithotripters and lasers.

Methods: A network meta-analysis was conducted following the Preferred Reporting Items for Systematic Reviews and Meta-Analysis guidelines. PubMed, Embase and Cochrane were utilised to search for randomised controlled trials (RCTs) up to 10 August 2024.

View Article and Find Full Text PDF

Characterization of skeletal muscle contraction using a flexible and wearable ultrasonic sensor.

Prog Mol Biol Transl Sci

September 2025

Department of Systems and Computer Engineering, Carleton University, Ottawa, ON, Canada. Electronic address:

Monitoring skeletal muscle contraction provides valuable information about the muscle mechanical properties, which can be helpful in various biomedical applications. This chapter presents a single-element flexible and wearable ultrasonic sensor (WUS) developed by our research group and its application for continuously monitoring and characterizing skeletal muscle contraction. The WUS is made from a 110-µm thick polyvinylidene fluoride piezoelectric polymer film.

View Article and Find Full Text PDF

This study aimed to improve the efficiency of decellularization and enhance the functional properties of vascular grafts to optimize their application in vascular repair. Rabbit abdominal aortas were used as the decellularization target, and ultrasound-assisted decellularization was performed using intermittent ultrasound at 100 W power, 20 kHz frequency, and 4 °C. Rabbit abdominal aortas were subjected to three different decellularization techniques.

View Article and Find Full Text PDF

Antimony (Sb) is extensively utilized in industrial activities, but most of its compounds exhibit human toxicity and are classified as priority-controlled pollutants. Unlike traditional electrochemical methods that remove metallic pollutants via coagulation or precipitation, electrochemical hydride generation technology converts antimony (Sb) in wastewater into stibine gas (SbH3) for efficient removal. Furthermore, the generated SbH₃ can be decomposed thermally to partially recover metallic antimony.

View Article and Find Full Text PDF