Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background And Aims: Lynch syndrome (LS) carries a substantial lifetime risk of colorectal cancer which is currently mitigated by biennial colonoscopy surveillance. Paramount to the surveillance programme is the removal of adenomas before malignant transformation but there is an associated service burden and morbidity of repeated endoscopy. We investigated if faecal immunochemical testing (FIT) for faecal haemoglobin has the diagnostic performance to replace colonoscopy.

Methods: In this retrospective cohort study, patients due to undergo planned surveillance for LS between November 2020 and April 2022 were sent two FIT kits prior to colonoscopy. Test diagnostic performance of colorectal cancer (CRC), advanced and non-advanced adenoma detection was calculated for single and double FIT strategies. A faecal-Hb of 10 µg Hb/g was considered positive.

Results: In total, 78 patients, with 45 (57.7%) female, median age 52 years (IQR 41-63), completed at least one FIT and colonoscopy. The median time from FIT to colonoscopy was 47 days. A single FIT was positive in 7/30 cases of adenoma (2/3 advanced, 5/27 non-advanced). A total of 64 (82.1% of FIT1T returners) completed a second FIT. Using the greatest of the two FITs (FIT2TMAX) 8/26 (2/3 advanced, 4/23 non-advanced), patients with adenomas were identified. There were no cases of CRC. The sensitivity for adenoma detection was 23.3% and 23.1%, respectively.

Conclusions: In patients with LS awaiting colonoscopy, FIT has a low sensitivity for detecting adenomas and advanced adenomas. This is not improved by the addition of a second FIT test.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11545718PMC
http://dx.doi.org/10.3390/diagnostics14212431DOI Listing

Publication Analysis

Top Keywords

diagnostic performance
12
fit
10
faecal immunochemical
8
immunochemical testing
8
testing fit
8
lynch syndrome
8
colorectal cancer
8
adenoma detection
8
fit colonoscopy
8
2/3 advanced
8

Similar Publications

Leveraging GPT-4o for Automated Extraction and Categorization of CAD-RADS Features From Free-Text Coronary CT Angiography Reports: Diagnostic Study.

JMIR Med Inform

September 2025

Departments of Radiology, The Third Affiliated Hospital, Sun Yat-Sen University, 600 Tianhe Road, Guangzhou, Guangdong, 510630, China, 86 18922109279, 86 20852523108.

Background: Despite the Coronary Artery Reporting and Data System (CAD-RADS) providing a standardized approach, radiologists continue to favor free-text reports. This preference creates significant challenges for data extraction and analysis in longitudinal studies, potentially limiting large-scale research and quality assessment initiatives.

Objective: To evaluate the ability of the generative pre-trained transformer (GPT)-4o model to convert real-world coronary computed tomography angiography (CCTA) free-text reports into structured data and automatically identify CAD-RADS categories and P categories.

View Article and Find Full Text PDF

Background: Circumcision is a widely practiced procedure with cultural and medical significance. However, certain penile abnormalities-such as hypospadias or webbed penis-may contraindicate the procedure and require specialized care. In low-resource settings, limited access to pediatric urologists often leads to missed or delayed diagnoses.

View Article and Find Full Text PDF

Objectives: Empty sella is the herniation of the subarachnoid space into the sella turcica; either secondary to identifiable causes (e.g., surgery or radiotherapy); or spontaneously, which is termed primary empty sella (PES).

View Article and Find Full Text PDF

In this study, employing a 2D electrodeposition in situ assembly method, a high-performance HS sensor based on a p-n type CuO-CuFeO heterostructure ordered nanowire arrays was successfully fabricated on silicon substrates. Compared to CuO, CuO-CuFeO nanowire arrays exhibits an ideal interfacial barrier structure and higher initial resistance, with a response to 10 ppm of HS at room temperature (20 ± 3 °C) increased by 225 times and a response time reduced by over 2400 s. The sensor demonstrates exceptional sensitivity (LOD = 10 ppb; response = 234.

View Article and Find Full Text PDF

This study aimed to develop a deep-learning model for the automatic classification of mandibular fractures using panoramic radiographs. A pretrained convolutional neural network (CNN) was used to classify fractures based on a novel, clinically relevant classification system. The dataset comprised 800 panoramic radiographs obtained from patients with facial trauma.

View Article and Find Full Text PDF