A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 1075
Function: getPubMedXML

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3195
Function: GetPubMedArticleOutput_2016

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Synthesis and mechanistic investigation of BPA fluorescent probes targeting BPA for potential application in Boron Neutron Capture Therapy (BNCT). | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Boronic acid analogs are crucial in modern organic chemistry and drug development, serving as versatile reagents and intermediates with significant therapeutic applications. This area has gained increased interest with the recent development of the drug 4-boron-L-phenylalanine (L-BPA) for boron neutron capture therapy (BNCT). Fluorescent probe technology offers an essential pathway for imaging drugs in vitro and in vivo, providing high sensitivity with great spatial and temporal resolution for both disease diagnosis and drug development. In this paper, we designed and investigated three fluorescent probes-W-1-NN, W-2-NS and W-3-NO-for sensing 4-boron-L-phenylalanine (L-BPA). Among these, only W-1-NN reacts with L-BPA, resulting in a spectral blue-shift change. This probe can "ratiometrically" and specifically detect L-BPA among various metals, with a limit of detection (LOD) of 7.11 μM. Mechanistic studies revealed that the addition of L-BPA disrupts the inherent ESIPT mechanism of W-1-NN in protonic solutions, resulting in the appearance of a new peak at 372 nm. Additionally, theoretical computational studies have also demonstrated that the complexation of W-1-NN with L-BPA triggers a change in the resonance structure, resulting in a larger energy gap and causing a blue shift in the spectrum. Furthermore, W-1-NN has been successfully applied to the detection of L-BPA in human urine. Therefore, the template probe with N/O as the target and the introduction of N atoms can specifically detect L-BPA. This template probe lays the foundation for the detection of L-BPA, and provides great possibilities for the future realization of the template probe to be connected with different fluorophores to make it emit at long wavelengths to reach the target of the near-infrared.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.saa.2024.125318DOI Listing

Publication Analysis

Top Keywords

template probe
12
l-bpa
9
boron neutron
8
neutron capture
8
capture therapy
8
therapy bnct
8
drug development
8
4-boron-l-phenylalanine l-bpa
8
detect l-bpa
8
detection l-bpa
8

Similar Publications