Background: Advanced imaging techniques play a pivotal role in oncology. A large variety of computed tomography (CT) scanners, scan protocols, and acquisition techniques have led to a wide range in image quality and radiation exposure. This study aims at implementing verifiable oncological imaging by quality assurance and optimization (i-Violin) through harmonizing image quality and radiation dose across Europe.
Methods: The 2‑year multicenter implementation study outlined here will focus on CT imaging of lung, stomach, and colorectal cancer and include imaging for four radiological indications: diagnosis, radiation therapy planning, staging, and follow-up. Therefore, 480 anonymized CT data sets of patients will be collected by the associated university hospitals and uploaded to a repository. Radiologists will determine key abdominopelvic structures for image quality assessment by consensus and subsequently adapt a previously developed lung CT tool for the objective evaluation of image quality. The quality metrics will be evaluated for their correlation with perceived image quality and the standardized optimization strategy will be disseminated across Europe.
Results: The results of the outlined study will be used to obtain European reference data, to build teaching programs for the developed tools, and to create a culture of optimization in oncological CT imaging.
Conclusion: The study protocol and rationale for i‑Violin, a European approach for standardization and harmonization of image quality and optimization of CT procedures in oncological imaging, is presented. Future results will be disseminated across all EU member states, and i‑Violin is thus expected to have a sustained impact on CT imaging for cancer patients across Europe.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11602843 | PMC |
http://dx.doi.org/10.1007/s00117-024-01389-8 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.
Radiother Oncol
September 2025
Dept of Radiation Oncology, Centre Léon Bérard, Lyon, France. Electronic address:
Background And Purpose: To date, no consensus guidelines have been published that systematically guide delineation of primary and nodal Clinical Target Volumes (CTVs) in patients who require post-operative radiotherapy (PORT) for mucosal Head and Neck squamous cell carcinoma (HNSCC). As a result, significant individual, institutional and national variation exists in the way that CTVs are delineated in the post-operative setting, leading to considerable heterogeneity in radiotherapy treatment.
Methods: A multi-disciplinary group of experts convened by the European Society for Radiotherapy and Oncology (ESTRO) set-out principles for the multi-disciplinary management of oral cavity squamous cell carcinoma (OCSCC).