Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

A lateral flow chromatography strip (LFS) is a chromatography-based biosensor with advantages of convenient portability, simple operation and rapid detection. In this study, a novel rapid detection technique of aptamer-based chromatography strip was developed and used for the first time for the residue detection of tetracycline antibiotics (TCs) in various milk samples. In this method, gold nanoparticles (AuNPs) modified by TCs specific aptamers were used as probes, and cationic polymers as capture molecules in a test line (T-line). Meanwhile, the analysis of the gray value of the T-line enabled a linear detection range of 1-300 nM and a limit of detection (LOD) of 0.33 nM for quantitative analysis. The biosensor demonstrated high specificity, good stability, and successfully detected tetracyclines in milk samples with recovery rate of 93.60%-106.20%. This method sets a basis for multi-residue antibiotics detection in diverse samples, showing potential for on-site applications.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.foodchem.2024.141743DOI Listing

Publication Analysis

Top Keywords

rapid detection
12
cationic polymers
8
detection tetracycline
8
tetracycline antibiotics
8
chromatography strip
8
milk samples
8
detection
7
strip biosensors
4
biosensors based
4
based broad-spectrum
4

Similar Publications

Soda biscuit-like Ag-ZnO@ZIF-8 heterostructures were successfully synthesized using a secondary hydrothermal method for the first time, demonstrating exceptional ethylene glycol sensing performance. The sample (2-Methylimidazol (MeIm) concentration of 0.04 g) exhibits a remarkable response value of 1325.

View Article and Find Full Text PDF

Severe pneumonia, as a critical and prevalent condition of the respiratory system, poses a significant threat to patient survival and health outcomes. This article focuses on the similarities and differences between community-acquired pneumonia (CAP) and hospital-acquired pneumonia (HAP)/ventilator-associated pneumonia (VAP). There is significant divergence in the predominant pathogens between severe community-acquired pneumonia (SCAP) and HAP/VAP.

View Article and Find Full Text PDF

Development of suitable carbohydrate-decorated, biocompatible, and stimuli-responsive fluorescent microgels that can selectively bind and detect proteins (such as lectins) is an important research topic. Herein, we report the development of mannose-decorated, dual-stimuli (temperature and pH)-responsive fluorescent poly(aminoamide) microgels, which can selectively bind to and thereby detect the presence of concanavalin A (Con A). The resultant stimuli-responsive microgels have a lower critical solution temperature (VPTT) of 37.

View Article and Find Full Text PDF

Objective: To determine optimal CT perfusion (CTP) imaging parameters for evaluating the canine prostate and to assess the diagnostic utility of CTP combined with cytopathologic evaluation and B-Raf proto-oncogene (BRAF) gene mutation testing in dogs with prostate adenocarcinoma.

Methods: For this study, 10 male dogs were enrolled, comprising 4 healthy Beagles and 6 client-owned dogs with suspected prostatic neoplasia. Computed tomography perfusion was performed in the healthy dogs using varied contrast agent doses and injection durations.

View Article and Find Full Text PDF

Rapid and sensitive acute leukemia classification and diagnosis platform using deep learning-assisted SERS detection.

Cell Rep Med

August 2025

Center for Biomedical-photonics and Molecular Imaging, Advanced Diagnostic-Therapy Technology and Equipment Key Laboratory of Higher Education Institutions in Shaanxi Province, School of Life Science and Technology, Xidian University, Xi'an, Shaanxi 710126, China; Engineering Research Center of Mole

Rapid identification and accurate diagnosis are critical for individuals with acute leukemia (AL). Here, we propose a combined deep learning and surface-enhanced Raman scattering (DL-SERS) classification strategy to achieve rapid and sensitive identification of AL with various subtypes and genetic abnormalities. More than 390 of cerebrospinal fluid (CSF) samples are collected as targets, encompassing healthy control, AL patients, and individuals with other diseases.

View Article and Find Full Text PDF