98%
921
2 minutes
20
: Recent advancements in hip arthroplasty aim to enhance the stability, longevity, and functionality of femoral implants. However, the distal fitting of femoral stems, often caused by metaphyseal-diaphyseal mismatch, remains a significant issue, particularly in patients with Dorr type A femora. Such mismatches can result in suboptimal implant performance, leading to potential complications. This study focuses on evaluating the anatomical compatibility of five representative single-tapered wedge mid-short stems with the mediolateral (ML) anatomy of the proximal femur in an East Asian population, where these mismatches are often more pronounced. : A total of 742 patients from two hospitals, all of whom underwent unilateral primary total hip arthroplasty, were included in the study. The contralateral proximal femur was confirmed to have normal anatomy in each patient. Hip anteroposterior radiographs were used for measurements, which were standardized in conjunction with CT images. Key anatomical parameters were measured, including proximal and distal medial-lateral canal dimensions, vertical offset, and medial offset. Five femoral stem designs-Tri-lock, Taperloc, Anthology, Accolade II, and Fit-were evaluated. R programming was employed for a detailed fit analysis to match stem sizes with patient anatomy, categorizing the fit as proximal, simultaneous proximal-distal, or distal engagement. : Among the femoral stems analyzed, the Fit stem demonstrated the closest alignment with the regression line for ML widths in the study population (slope = 0.69; population ML slope = 0.38). This was followed by Accolade II, which had a slope of 0.83. In terms of offset options, the Accolade II offered the largest offset coverage, making it particularly suitable for this population. The fit analysis revealed that the Fit stem had the highest suitable fit rate (90.56%), followed by Accolade II (73.04%). Taperloc, Anthology, and Tri-lock had similar fit rates of approximately 59%. Overall, optimal results were obtained for 92.05% of the population in the automated fitting trial, regardless of the product type. : When designing modern cementless femoral stems intended for press-fit fixation, it is crucial to account for the anatomical variations specific to the target population. In this study, Fit and Accolade II femoral components demonstrated superior compatibility with the femoral anatomy of the East Asian population, particularly in those with a higher incidence of Dorr type A femora. These stems, characterized by slimmer distal dimensions and high-offset options, appear to minimize metaphyseal-diaphyseal mismatch and associated complications.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11509231 | PMC |
http://dx.doi.org/10.3390/jcm13206030 | DOI Listing |
Interact J Med Res
September 2025
Department of Medicine, MacKay Medical College, New Taipei, Taiwan.
Background: Dengue fever remains the most significant vector-borne disease in Southeast Asia, imposing a substantial burden on public health systems. Global warming and increased international mobility may exacerbate the disease's prevalence. Furthermore, the unprecedented COVID-19 pandemic may have influenced the epidemiological patterns of dengue.
View Article and Find Full Text PDFPLoS One
September 2025
People's Hospital of Ningxia Hui Autonomous Region, Ningxia Eye Hospital, Yinchuan, China.
Purpose: To investigate the variants in 18 disease-causing genes associated with nonsyndromic myopia in 83 Chinese individuals diagnosed with early-onset high myopia(eo-HM).
Methods: Variants in 18 candidate genes in 83 probands with eo-HM were distinguished by whole-exome sequencing (WES) and assessed by multistep bioinformatics analysis.
Results: Four likely pathogenic variants were detected in 4 of the 83 probands (4.
PLoS One
September 2025
School of Economics, Minzu University of China, Beijing, China.
This study applies Fisher's investment framework to investigate how patient capital affects firms' green total factor productivity (GTFP). Using panel data from Chinese listed companies over the period 2008-2023, we measure firm-level GTFP by employing a non-radial SBM directional distance function combined with the Malmquist-Luenberger productivity index. Our analysis, based on two-way fixed-effects models and instrumental variable regressions, reveals that an increase in patient capital significantly enhances firms' green total factor productivity.
View Article and Find Full Text PDFCell
July 2025
Hebei International Joint Research Center for Paleoanthropology, Hebei GEO University, Shijiazhuang 050031, China.
Denisovans have yet to be directly associated with a hominin cranium, limiting our understanding of their morphology and geographical distribution. We have attempted to retrieve DNA from a nearly complete Middle Pleistocene cranium from Harbin (>146 ka), northeastern China. Although no DNA could be retrieved from a tooth or the petrous bone, mitochondrial DNA (mtDNA) could be isolated from dental calculus.
View Article and Find Full Text PDFOphthalmic Plast Reconstr Surg
September 2025
Division of Orbital and Ophthalmic Plastic Surgery.
Purpose: To objectively quantify, in East Asians and Caucasians, the width and distribution of the retro-orbicularis oculi and frontalis fat (ROOF) pad, subcutaneous fat, and orbicularis oculi muscle (OOM) at the superior orbital rim margin as well as 5 mm superior and inferior to this point.
Methods: Thirty adults were studied by high-resolution, surface coil MRI. In the quasi-sagittal image through the globe center, the ROOF, subcutaneous fat, and OOM thickness were measured anterior to the orbital septum, at 3 points: at the superior orbital rim, and 5 mm superior, and 5 mm inferior to the rim.