Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: MRI (magnetic resonance imaging) represents the diagnostic image modality of choice in several conditions. With an increasing number of patients requiring MRI for diagnostic purposes, the issue of safety in patients with cardiac implantable electronic devices (CIED) undergoing this imaging modality will play an ever more important role. The purpose of this study was to assess the safety and device function following MRI in an unrestricted real-world cohort of patients with a wide array of cardiac devices.

Methods: We conducted a retrospective single-center study including 1010 MRI studies conducted in adult patients (≥18 years) with an implanted CIED treated in the University Hospital of Munich (LMU) between July 2012 and March 2024. Patients with non-MR conditionally labeled leads, abandoned or epicardial leads, as well as lead fragments, were included for analysis.

Results: Across a total of 1010 MRIs (920 total MR-conditional device generators) performed in patients with an implanted CIED, there were no deaths, reports of discomfort, palpitations, heating, or ventricular arrythmias in the 24 h following MRI. Only 2/1010 MRIs were followed by a reported atrial arrhythmia within 24 h, both in patients with an MR-conditional pacemaker (PM) device without an abandoned lead. No significant changes in device function following MRI from baseline were observed across all included CIEDs. Lastly, no instances of severe malfunction, such as generator failure, loss of capture, electrical reset, or inappropriate inhibition of pacing, were found in post-MRI interrogation reports across all MRI studies.

Conclusions: Based on the analysis of 1010 MRIs undergone by patients with CIEDs, following standardized device interrogation, manufacturer-advised device programming, monitoring of vital function, and manufacturer-advised reprogramming, MRI can be performed safely and without adverse events or changes in device function.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11509009PMC
http://dx.doi.org/10.3390/jcdd11100313DOI Listing

Publication Analysis

Top Keywords

device function
12
patients
9
magnetic resonance
8
resonance imaging
8
patients cardiac
8
cardiac implantable
8
implantable electronic
8
electronic devices
8
mri
8
function mri
8

Similar Publications

Background: The COVID-19 pandemic forced the world to quarantine to slow the rate of transmission, causing communities to transition into virtual spaces. Asian American and Pacific Islander communities faced the additional challenge of discrimination that stemmed from racist and xenophobic rhetoric in the media. Limited data exist on technology use among Asian American and Pacific Islander adults during the height of the COVID-19 shelter-in-place period and its effect on their physical and mental health.

View Article and Find Full Text PDF

Tuning the Electrical Property and Electronic Band Structures of Organic Semiconductors via Surface Tension.

J Phys Chem Lett

September 2025

National Laboratory of Solid-State Microstructures, School of Electronic Science and Engineering, Collaborative Innovation Center of Advanced Microstructures, Nanjing University, Nanjing 210093, P. R. China.

Stress engineering is an effective way to tune the performance of semiconductors, which has been verified in the work of inorganic and organic single-crystal semiconductors. However, due to the limitations of the vapor-phase growth preparation conditions, the deposited polycrystalline organic semiconductors are more susceptible to residual stress. Therefore, it is of great research significance to develop a low-cost stress engineering applicable to vapor-deposited semiconductors.

View Article and Find Full Text PDF

The human auditory system must distinguish relevant sounds from noise. Severe hearing loss can be treated with cochlear implants (CIs), but how the brain adapts to electrical hearing remains unclear. This study examined adaptation to unilateral CI use in the first and seventh months after CI activation using speech comprehension measures and electroencephalography recordings, both during passive listening and an active spatial listening task.

View Article and Find Full Text PDF

The role of assistive devices and technologies in the activities and participation in everyday life of children with cerebral palsy - a scoping review.

Disabil Rehabil Assist Technol

September 2025

Department of Special Needs Education and Rehabilitation, Department Pedagogy and Didactics for People with Physical and Motor Development Impairments and Chronic and Progressive Illnesses, Carl von Ossietzky University, Oldenburg, Germany.

Objectives: Many studies investigate the impact of assistive devices and technologies (AD/AT) on physical outcomes. The role of AD/ATs in everyday activities and participation of children with cerebral palsy (CP) has received much less attention. This review scopes the impact of AD/ATs by the activities and participation components of the International Classification of Functioning, Disability and Health (ICF) model.

View Article and Find Full Text PDF

The increasing use of blood-contacting medical devices has brought about significant advancements in patient care, yet it also presents challenges such as thrombus formation and infection risks. Surface coatings play a vital role in mitigating these side effects, enhancing the safety and effectiveness of such devices. In this study, we introduced a novel coating employing poly(aspartic acid) (PASP), which can be easily applied through various modification pathways.

View Article and Find Full Text PDF