Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Aims: Limited knee range-of-motion (ROM) is common following total knee arthroplasty (TKA). It is associated with functional limitations and patient dissatisfaction. Regular knee ROM assessment is important but accurate testing traditionally requires timely access to trained healthcare professionals. Although accelerometer-based smartphone goniometry has shown to provide reliable and valid joint angles, current evidence of its use still positions healthcare providers as end users instead of patients themselves. Therefore, to maximize the impact of smartphone goniometry on post-TKA care, our study aimed to examine the feasibility, reliability, and validity of patients' self-measurement of knee ROM using an accelerometer-based smartphone goniometry application.

Methods: Patients were given standard instructions with a practice trial before the actual measurements. Passive knee flexion and extension ROM was measured on 2 sessions in 30 patients with TKA using 4 block-randomized methods: (i) smartphone self-assessment, (ii) long-arm goniometry by physiotherapist, (iii) smartphone assessment by physiotherapist, and (iv) extendable-arm goniometry by physiotherapist with placement adjudication. Feasibility was assessed by the number of participants who could independently perform the self-measurement. To assess intra- and inter-session reliability, we computed intraclass correlation coefficients (ICCs) from random-effects models. To assess intra- and inter-session agreement, we computed mean absolute differences (MADs) and minimum detectable change (MDC). To assess concurrent validity, we designated extendable-arm goniometry as the "gold standard" and compared other methods against it using ICCs and MADs.

Results: All patients were able to comprehend and execute the assessment. 87% (n = 26) found the application easy to administer. Smartphone goniometry by patients showed excellent intra- and inter-session reliability (ICCs>0.97) and minimum variability (MAD = 0.9°-3.9°; MDC95 = 3.1°-9.0°). Smartphone or long-arm goniometry by physiotherapists did not outperform patients' self-assessment (ICC = 0.96-0.99, MAD = 0.7°-3.1°; MDC95 = 2.2°-8.0°). Compared against extendable-arm goniometry, smartphone goniometry by patients measured knee flexion and extension ROM with a MAD of 4.5° (ICC, 0.97) and 2.2° (ICC = 0.98), respectively.

Conclusion: Our study demonstrates that smartphone goniometry is feasible, reliable and accurate, and can be used with confidence in the self-assessment of knee ROM post-TKA. Future studies should further explore its utility in telemonitored rehabilitation, and its possible integration into mobile health applications to enhance accessibility to care following TKA.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11449355PMC
http://journals.plos.org/plosone/article?id=10.1371/journal.pone.0307219PLOS

Publication Analysis

Top Keywords

smartphone goniometry
24
accelerometer-based smartphone
12
knee rom
12
extendable-arm goniometry
12
intra- inter-session
12
goniometry
11
smartphone
10
knee
9
feasibility reliability
8
reliability validity
8

Similar Publications

Objective assessment of penile curvature in hypospadias: A narrative review.

J Pediatr Urol

August 2025

Pediatric Urology Section, Surgery Department, Sidra Medicine, Doha, Qatar; College of Medicine, Qatar University, Doha, Qatar; Department of Surgery, Weill Cornell Medicine Qatar, Doha, Qatar.

Background: Hypospadias-associated ventral curvature (VC) exerts a critical influence on surgical decision-making and repair outcomes. Despite the clinical significance of VC, assessment is frequently performed by unaided visual inspection (UVI) which is prone to error. Alternative objective measurement techniques have therefore been proposed, including goniometry, smartphone applications, and artificial intelligence (AI)-based tools.

View Article and Find Full Text PDF

Objectives: To systematically review studies involving the reliability of the lower limbs joint range of motion (ROM) by goniometer, photogrammetry and smartphone applications in young and healthy subjects.

Data Sources: The search was conducted between December 2020 and January 2021 in PubMed, Embase, LILACS, OVID, and SciELO databases.

Study Selection Or Eligibility Criteria: Studies that evaluated the reliability of the lower limb joints ROM measurements.

View Article and Find Full Text PDF
Article Synopsis
  • After knee surgery, many people struggle to move their knees properly, which can make them unhappy and limit their activities.
  • This study looked at whether patients could accurately measure their knee movement using a special app on their smartphones instead of needing a healthcare professional.
  • The results showed that almost all patients could use the app easily, and it gave very reliable measurements of knee movement.
View Article and Find Full Text PDF

Background: Typically, shoulder range of motion (ROM) measurements are performed in a clinic setting, where physicians, physical therapists (PTs), and occupational therapists make use of a goniometer.

Purpose: To determine the accuracy of a smartphone-based ROM software application (app) in assessing active shoulder ROM and compare the measurements with traditional goniometry as measured by a PT.

Study Design: Cohort study (diagnosis); Level of evidence, 2.

View Article and Find Full Text PDF

The concurrent validity and reliability of virtual reality to measure shoulder flexion and scaption range of motion.

Physiotherapy

September 2023

Therapy Department, Central London Community Healthcare National Health Service Trust, London, United Kingdom; Department of Musculoskeletal Research, Clinical Therapies, University of Limerick, Ireland.

Background: Shoulder pain commonly has a detrimental impact on patient's work and social activities. Although pain is the most common reason for seeking care, a reduction in shoulder range of motion (ROM) is another common impairment. ROM assessment is used as an evaluation tool and multiple methods are available to measure shoulder ROM.

View Article and Find Full Text PDF