A PHP Error was encountered

Severity: Warning

Message: file_get_contents(https://...@gmail.com&api_key=61f08fa0b96a73de8c900d749fcb997acc09&a=1): Failed to open stream: HTTP request failed! HTTP/1.1 429 Too Many Requests

Filename: helpers/my_audit_helper.php

Line Number: 197

Backtrace:

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 197
Function: file_get_contents

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 271
Function: simplexml_load_file_from_url

File: /var/www/html/application/helpers/my_audit_helper.php
Line: 3165
Function: getPubMedXML

File: /var/www/html/application/controllers/Detail.php
Line: 597
Function: pubMedSearch_Global

File: /var/www/html/application/controllers/Detail.php
Line: 511
Function: pubMedGetRelatedKeyword

File: /var/www/html/index.php
Line: 317
Function: require_once

Comparative Study of the Influence of Dental Implant Design on the Stress and Strain Distribution using the Finite Element Method. | LitMetric

Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Background: One emerging and important research method for biomechanical assessments in biological investigations is the finite element analysis (FEA). It is the best technique for simulating intricate structures and examining their mechanical characteristics.

Aim: This study was conducted to compare the V-shaped design and square thread design regarding their influence on the stress and strain distribution using the finite element method.

Methods And Materials: Forty dental implants with two different designs were used. These designs were V-shaped design and square design. Utilizing Creo 2.0, cortical bone, cancellous bone, and implants were modeled. FEM analysis was performed on forty model assemblies.

Results: It was observed that mean load 1 values for squared thread design were lesser as compared to V-shaped thread design at coronal one-third middle one-third and apical one-third in the cancellous bone as well as implant surface.

Conclusion: The design of implant is an important factor influencing the stress and strain distribution using the finite element method with a square design showing reduced concentration.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11426794PMC
http://dx.doi.org/10.4103/jpbs.jpbs_432_24DOI Listing

Publication Analysis

Top Keywords

finite element
16
stress strain
12
strain distribution
12
distribution finite
12
thread design
12
design
9
element method
8
v-shaped design
8
design square
8
square design
8