Introduction: Left bundle branch area pacing (LBBAP) comprises pacing at the left ventricular septum (LVSP) or left bundle branch (LBBP). The aim of the present study was to investigate the differences in ventricular electrical heterogeneity between LVSP, LBBP, right ventricular pacing (RVP) and intrinsic conduction with different dyssynchrony measures using the ECG, vectorcardiograpy, ECG belt, and Ultrahigh frequency (UHF-)ECG.

Methods: Thirty-seven patients with a pacemaker indication for bradycardia or cardiac resynchronization therapy underwent LBBAP implantation. ECG, vectorcardiogram, ECG belt and UHF-ECG signals were recorded during RVP, LVSP and LBBP, and intrinsic activation. QRS duration (QRSd) was measured from the ECG, QRS area was calculated from the vectorcardiogram, LV activation time (LVAT) and standard deviation of activation time (SDAT) from ECG belt and electrical dyssynchrony (e-DYS16) from UHF-ECG.

Results: Both LVSP and LBBP significantly reduced ventricular electrical heterogeneity as compared to underlying LBBB and RV pacing in terms of QRS area (p < .001), SDAT (p < .001), LVAT (p < .001) and e-DYS16 (p < .001). QRSd was only reduced as compared to RV pacing(p < .001). QRS area was similar during LBBP and normal intrinsic conduction, e-DYS16 was similar during LVSP and normal intrinsic conduction, whereas SDAT was similar for LVSP, LBBP and normal intrinsic conduction. For all these variables there was no significant difference between LVSP and LBBP.

Conclusion: Both LVSP and LBBP resulted in a more synchronous LV activation than LBBB and RVP. Especially LBBP resulted in levels of LV synchrony comparable to normal intrinsic conduction.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11650391PMC
http://dx.doi.org/10.1111/jce.16435DOI Listing

Publication Analysis

Top Keywords

ventricular electrical
12
electrical heterogeneity
12
left bundle
12
bundle branch
12
lvsp lbbp
12
ecg belt
12
pacing left
8
left ventricular
8
qrs area
8
activation time
8

Similar Publications

Gap junctions (GJs) are critical structures for cardiac electrical signal conduction and synchronized contraction. Their fundamental components are transmembrane proteins from the connexin (Cx) family, which assemble into hexameric channels to form intercellular ion-permeable pathways, ensuring efficient electrical transmission and coordinated contraction between cardiac cells. Connexin 43 (Cx43), the most abundant connexin in the heart, serves as the primary constituent of ventricular gap junctions.

View Article and Find Full Text PDF

Mechanism of post cardiac arrest syndrome based on animal models of cardiac arrest.

Zhong Nan Da Xue Xue Bao Yi Xue Ban

May 2025

Scool of Disaster and Emergency Medicine, Tianjin University, Tianjin 300072.

Cardiac arrest (CA) is a critical condition in the field of cardiovascular medicine. Despite successful resuscitation, patients continue to have a high mortality rate, largely due to post CA syndrome (PCAS). However, the injury and pathophysiological mechanisms underlying PCAS remain unclear.

View Article and Find Full Text PDF

Many Arctic fishes experience prolonged periods of extreme cold and large thermal variation over both rapid and seasonal time scales which challenge critical physiological functions. In the central Canadian Arctic, we caught wild adult lake trout (Salvelinus namaycush) acclimatized to winter and summer temperatures to determine the extent to which they seasonally adjust cardiac thermal performance and adrenergic control. We assessed the intrinsic and maximum heart rate (f and f) of anaesthetised fish through cholinergic blockade and either adrenergic blockade (f) or stimulation (f) during acute warming.

View Article and Find Full Text PDF

To investigate single versus combination hemodynamic parameters on intraventricular hemorrhage (IVH) or mortality in preterm infants. Data from 482 infants under 32 weeks gestational age were analyzed, including cerebral oximetry, mean arterial pressure (MAP), cardiac output, and systemic blood flow within the first 24 h. Wilcoxon Rank-Sum and chi-squared tests compared variables.

View Article and Find Full Text PDF

Background: Anti-tachycardia pacing (ATP) delivered from implantable cardioverter defibrillators (ICDs) provides critically timed pacing pulses to terminate ventricular tachycardia (VT). Physiological pacing through left bundle branch area (LBBA) pacing has emerged as a clinically relevant alternative to induce synchronous activation of the ventricles. The main objective of this study was to compare the efficacy and safety of ATP delivered to an LBBA lead and a conventional RV lead.

View Article and Find Full Text PDF