Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Erectile dysfunction (ED) is a prevalent type of sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky and nonwearable and strongly interferes with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system that employs a measurement principle without active loads, allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. An integrated flexible printed circuit (FPC) collects and processes sensing signals, which are then transmitted to the host computer via Bluetooth for ED assessment. Additionally, we validated the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections. In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than existing technologies. Erectile dysfunction (ED) is a prevalent sexual dysfunction, and continuous monitoring of penile tumescence and rigidity during spontaneous nocturnal erections is crucial for its diagnosis and classification. However, the current clinical standard device, limited by its active mechanical load, is bulky, nonwearable, and creates pronounced interference with erections, which compromises both monitoring reliability and patient compliance. Here, we report a wearable adaptive rigidity monitoring (WARM) system (Fig. 1a) that employs a measurement principle without active loads (Fig. 1b), allowing for the assessment of penile tumescence and rigidity through a specifically designed elastic dual-ring sensor. The dual-ring sensor, comprising two strain-sensing rings with distinct elastic moduli, provides high resolution (0.1%), robust mechanical and electrical stability (sustaining over 1000 cycles), and strong interference resistance. Additionally, we validate the WARM system against the clinical standard device using both a penile model and healthy volunteers, achieving high consistency. Furthermore, the system facilitates the continuous evaluation of penile erections during nocturnal tumescence tests, with concurrent sleep monitoring, demonstrating its ability to minimize interference with nocturnal erections (Fig. 1c). In conclusion, the WARM system offers a fully integrated, wearable solution for continuous, precise, and patient-friendly measurement of penile tumescence and rigidity, potentially providing more reliable and accessible outcomes than those from existing technologies.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413319PMC
http://dx.doi.org/10.1038/s41378-024-00721-5DOI Listing

Publication Analysis

Top Keywords

penile tumescence
24
tumescence rigidity
24
warm system
24
nocturnal erections
16
clinical standard
16
standard device
16
dual-ring sensor
16
wearable adaptive
12
rigidity monitoring
12
erectile dysfunction
12

Similar Publications

Objective: Conventional penile venous surgery for erection restoration and surgery for penile augmentation have been controversial. Based on de novo penile fibrovascular assembly, we report innovative penile venous stripping (PVS) and factual penile girth enhancement (FPGE).

Methods: From 2013 to 2023, refractory impotence and dysmorphia prompted 31 patients to seek PVS and FPGE, and all of them were confirmed with veno-occlusive dysfunction.

View Article and Find Full Text PDF

Background: Vitamin D, sometimes referred to as the "sunshine vitamin", is well-known for its role in maintaining bone health processes that are highly dependent on calcium regulation. However, there is an emerging wealth of evidence that this fat-soluble vitamin has an important role in male sexual health regarding erectile function, production of testosterone, and overall fertility. Due to the increased vitamin D deficiency rates in most populations, the implications of its deficiency on male sexual functions have gained great interest.

View Article and Find Full Text PDF

Objective: Assess results of simultaneous ligation and embolization for caverno-venous leakage (CVL) in patients with erectile dysfunction (ED) resistant to 5-Phosphodiesterase inhibitors.

Patients And Methods: Data from consecutive patients with ED operated-on for CVL, were collected prospectively. CVLs were diagnosed by Pharmacologicaly-Challenged Penile Duplex Sonography (PC-PDS) and computed tomography cavernosography.

View Article and Find Full Text PDF

Amniotic fluid stem cell therapy improves erectile function in a diabetic rat model.

Andrology

September 2025

Department of Urology, Knuppe Molecular Urology Laboratory, School of Medicine, University of California, San Francisco, California, USA.

Background: Current treatments for diabetic erectile dysfunction, such as phosphodiesterase type 5 inhibitors, penile injection, or vacuum erection devices, primarily offer symptomatic relief and do not address the underlying pathophysiology, which involves neural, vascular, and smooth muscle degeneration.

Objectives: This study aimed to evaluate the therapeutic potential of amniotic fluid-derived stem cells in a rat model of diabetic erectile dysfunction by assessing their impact on erectile function and penile tissue regeneration.

Methods: Male Sprague‒Dawley rats were divided into control, diabetic, and amniotic fluid-derived stem cell-treated diabetic groups.

View Article and Find Full Text PDF

Objectives: To provide a comprehensive summary of the surgical outcomes of Zephyr Surgical Implants (ZSI; Geneva, Switzerland) hydraulic and malleable female-to-male (FTM) penile implants (PIs) in transgender patients.

Patients And Methods: All transgender patients who underwent hydraulic (ZSI FTM 475) and malleable (ZSI FTM 100) erectile device implantation between January 2017 and March 2024 were retrospectively identified. Demographics, perioperative characteristics, postoperative complications, and re-operations were recorded.

View Article and Find Full Text PDF