Measuring, processing, and generating partially coherent light with self-configuring optics.

Light Sci Appl

E. L. Ginzton Laboratory, Stanford University, 348 Via Pueblo, Stanford, CA, 94305, USA.

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Optical phenomena always display some degree of partial coherence between their respective degrees of freedom. Partial coherence is of particular interest in multimodal systems, where classical and quantum correlations between spatial, polarization, and spectral degrees of freedom can lead to fascinating phenomena (e.g., entanglement) and be leveraged for advanced imaging and sensing modalities (e.g., in hyperspectral, polarization, and ghost imaging). Here, we present a universal method to analyze, process, and generate spatially partially coherent light in multimode systems by using self-configuring optical networks. Our method relies on cascaded self-configuring layers whose average power outputs are sequentially optimized. Once optimized, the network separates the input light into its mutually incoherent components, which is formally equivalent to a diagonalization of the input density matrix. We illustrate our method with numerical simulations of Mach-Zehnder interferometer arrays and show how this method can be used to perform partially coherent environmental light sensing, generation of multimode partially coherent light with arbitrary coherency matrices, and unscrambling of quantum optical mixtures. We provide guidelines for the experimental realization of this method, including the influence of losses, paving the way for self-configuring photonic devices that can automatically learn optimal modal representations of partially coherent light fields.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11413175PMC
http://dx.doi.org/10.1038/s41377-024-01622-yDOI Listing

Publication Analysis

Top Keywords

partially coherent
20
coherent light
16
partial coherence
8
degrees freedom
8
light
6
partially
5
coherent
5
method
5
measuring processing
4
processing generating
4

Similar Publications

Contribution of vestibular afference to estimation of centre of mass state for stabilization of walking differs between anteroposterior and mediolateral directions.

Neuroscience

September 2025

Department of Human Movement Sciences, Faculty of Behavioral and Movement Sciences, Vrije Universiteit Amsterdam, Amsterdam Movement Sciences, Amsterdam, the Netherlands. Electronic address:

Walking without falling requires correcting the deviations of the centre of mass (CoM) trajectory relative to the base of support. This process is partially under feedback control. We investigated whether vestibular afference contributes to estimating CoM state to stabilize walking.

View Article and Find Full Text PDF

Leveraging Partial Coherence to Enhance Nanoparticle Detection Sensitivity and Throughput in Interferometric Scattering Microscopy.

ACS Photonics

August 2025

Nanophotonic Systems Laboratory, Department of Mechanical and Process Engineering, ETH Zurich, Tannenstrasse 3, Zurich 8092, Switzerland.

Interferometric-based microscopies stand as powerful label-free approaches for monitoring and characterizing chemical reactions and heterogeneous nanoparticle systems in real time with single-particle sensitivity. Nevertheless, coherent artifacts, such as speckle and parasitic interferences, together with limited photon fluxes from spatially incoherent sources, pose an ongoing challenge in achieving both high sensitivity and throughput. In this study, we systematically characterize how partial coherence affects the signal contrast and background noise level in inline holography microscopes operated in a reflection geometry, a category that encompasses interferometric scattering microscopy (iSCAT).

View Article and Find Full Text PDF

Multiple Sclerosis (MS), an autoimmune disorder, is characterized by severe neuroinflammation, leading to demyelination and neuronal damage in the CNS, resulting in significant clinical impairment. MS progression involves complex pathological processes like immune cell invasion and cytokine-mediated recruitment to the CNS. Experimental autoimmune encephalomyelitis (EAE), widely used as a model for MS, despite its translational limitations, has been crucial for identifying effective treatments.

View Article and Find Full Text PDF

Neuro-Ophthalmology Referral Patterns: Learnings From Colombia.

J Neuroophthalmol

August 2025

College of Medicine (SS), University of Florida, Gainesville, Florida; Escuela de Medicina. Fundación Universitaria Sanitas, Bogotá (LR-S, JVR-L), Colombia; Vision Colombia Research Group (JVR-L), Fundación Universitaria Sanitas, Bogota, Colombia; and Department of Ophthalmology (AJM-V), College

Background: There is a global shortage of neuro-ophthalmologists, driven by an aging workforce and declining interest among residents. Emerging data indicate that this supply-demand mismatch results in prolonged patient wait times, leading to evaluation by additional physicians, delayed/incorrect diagnosis, and postponed therapy. However, data on referral patterns are primarily from resource-rich countries.

View Article and Find Full Text PDF

It is newly proposed that the presence of the near dipole-dipole (NDD) interaction effect in an optically dense atomic ensemble may be very useful for controlling high-precision atom localization. In the present work based on observing the NDD effect-induced space-dependent-absorption of a weak probe field operating in a partially closed four-level Y-type atomic system, we have shown the NDD parameter being an efficient control knob along with the other system parameters for easier optimization of the localization pattern with enhanced detection probability in three-dimensional (3D) space. Controlling localization patterns at lower and larger values of NDD parameter is discussed at different physical conditions.

View Article and Find Full Text PDF