Purpose: To develop fully-automated abdominal organ segmentation algorithms from non-enhanced abdominal CT and low-dose chest CT and assess their feasibility for automated CT volumetry and 3D radiomics analysis of abdominal solid organs.
Methods: Fully-automated nnU-Net-based models were developed to segment the liver, spleen, and both kidneys in non-enhanced abdominal CT, and the liver and spleen in low-dose chest CT. 105 abdominal CTs and 60 low-dose chest CTs were used for model development, and 55 abdominal CTs and 10 low-dose chest CTs for external testing. The segmentation performance for each organ was assessed using the Dice similarity coefficients, with manual segmentation results serving as the ground truth. Agreements between ground-truth measurements and model estimates of organ volume and 3D radiomics features were assessed using the Bland-Altman analysis and intraclass correlation coefficients (ICC).
Results: The models accurately segmented the liver, spleen, right kidney, and left kidney in abdominal CT and the liver and spleen in low-dose chest CT, showing mean Dice similarity coefficients in the external dataset of 0.968, 0.960, 0.952, and 0.958, respectively, in abdominal CT, and 0.969 and 0.960, respectively, in low-dose chest CT. The model-estimated and ground truth volumes of these organs exhibited mean differences between - 0.7% and 2.2%, with excellent agreements. The automatically extracted mean and median Hounsfield units (ICCs, 0.970-0.999 and 0.994-0.999, respectively), uniformity (ICCs, 0.985-0.998), entropy (ICCs, 0.931-0.993), elongation (ICCs, 0.978-0.992), and flatness (ICCs, 0.973-0.997) showed excellent agreement with ground truth measurements for each organ; however, skewness (ICCs, 0.210-0.831), kurtosis (ICCs, 0.053-0.933), and sphericity (ICCs, 0.368-0.819) displayed relatively low and inconsistent agreement.
Conclusion: Our nnU-Net-based models accurately segmented abdominal solid organs in non-enhanced abdominal and low-dose chest CT, enabling reliable automated measurements of organ volume and specific 3D radiomics features.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11821665 | PMC |
http://dx.doi.org/10.1007/s00261-024-04581-5 | DOI Listing |
Front Oncol
August 2025
School of Medicine, Kaiser Permanente Bernard J. Tyson School of Medicine, Pasadena, CA, United States.
Rationale: The national average rate of lung cancer screening (LCS) has remained low at roughly 6%, with California's rate among the lowest at 1% compared to all fifty states.
Methods: We enrolled Kaiser Permanente Northern California (KPNC) patients eligible for LCS per the USPSTF guidelines published in 2013 and 2021, respectively. Annual and overall rates of completed initial low-dose computed tomography of chest (LDCT) were computed from February 2015 to February 2022.
Chest
September 2025
Medical Research Institute of New Zealand, Wellington, New Zealand, ; Victoria University of Wellington, Wellington, New Zealand.
Background: High doses of maintenance inhaled corticosteroids (ICS) in asthma may achieve only modest additional clinical benefit beyond low-to-medium doses and are associated with an increased risk of adverse systemic effects. The ICS dose-response relationship when administered as maintenance combination ICS/long-acting beta-agonist (LABA) therapy is uncertain.
Research Question: What is the ICS dose-response of maintenance ICS/LABA therapy?
Methods: A systematic review of randomized controlled trials (RCTs) allocating participants to >1 ICS dose category, per Global Initiative for Asthma categorization, administered in combination ICS/LABA inhalers was conducted.
Background: Photon-counting detector computed tomography (PCD CT) offers higher dose efficiency than conventional energy-integrating detector CT (EID CT), which is particularly beneficial for children. Broad evidence is missing whether frequently acquired pediatric low-dose lung imaging can be further improved using PCD CT.
Objective: To compare radiation exposure, quantitative and qualitative image quality of pediatric low-dose chest PCD CT versus EID CT examinations.
J Dermatolog Treat
December 2025
Department of Dermatology, Hangzhou Third People's Hospital, Zhejiang, China.
Purpose: Sarcoidosis is a chronic, multisystem granulomatous disorder characterized histologically by non-caseating granulomas. Despite the availability of various therapeutic options, long-term disease control remains a significant clinical challenge.
Materials And Methods: We report the case of a 55-year-old female diagnosed with sarcoidosis.
Aging Dis
August 2025
Beijing Chest Hospital, Capital Medical University, Beijing Tuberculosis and Thoracic Tumor Research Institute, Beijing, China.
China's aging population faces a growing burden of chronic respiratory diseases, straining the public health system. Despite the Healthy China 2030 plan's emphasis on prevention and early detection, systemic barriers, such as low public awareness, urban-rural disparities, fragmented screening models, and uneven specialist distribution, hinder effective pulmonary care for older adults. To address these challenges, a shift toward community-based strategies, including mobile low-dose CT (LDCT) screening units, is proposed.
View Article and Find Full Text PDF