Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Purpose: This study aims to analyze the imaging features of isolated congenital middle ear malformation (CMEM) on high-resolution computed tomography (HRCT).

Methods: We retrospectively collected patients with surgically confirmed diagnosis of isolated CMEM in our hospital between January 2018 and June 2023. All patients underwent HRCT before surgery. The preoperative imaging findings were analyzed by neuroradiologists with full knowledge of the intraoperative findings.

Results: 37 patients were included in this study, including 25 males and 12 females, with a median age of 16 years. A total of 44 ears underwent surgery. The most commonly affected structures were incudostapedial joint, incus long process, and stapes superstructure, followed by stapes footplate, oval window, incudomalleolar join, tympanic segment of the facial nerve canal, incus body, incus short process and malleus. All incus defect/hypoplasia/malposition, stapes superstructure deformity, malleus deformity, incudostapedial joint discontinuity, and facial nerve canal malposition/abnormal bifurcation could be observed on HRCT. Additionally, 96.0% of stapes superstructure defect, 85.7% of oval window atresia, and 41.7% of incudomalleolar joint fusion, could be visualized on HRCT. HRCT could not show ossicular soft tissue pseudo-connection and stapes footplate fixation.

Conclusions: Preoperative HRCT is an important tool for diagnosing isolated CMEM. The advantages of HRCT lie in its ability to detect ossicular defects/deformities, incudostapedial joint discontinuity, oval window atresia, and facial nerve abnormalities. However, it has a low detection rate for incudomalleolar joint fusion and cannot show ossicular soft tissue pseudo-connection and stapes footplate fixation.

Download full-text PDF

Source
http://dx.doi.org/10.1007/s00234-024-03465-1DOI Listing

Publication Analysis

Top Keywords

incudostapedial joint
12
stapes superstructure
12
stapes footplate
12
oval window
12
facial nerve
12
imaging findings
8
isolated congenital
8
congenital middle
8
middle ear
8
ear malformation
8

Similar Publications

Objective: To directly compare the image quality of photon-counting detector CT (PCD-CT) and conventional energy-integrating detector CT (EID-CT) for temporal bone imaging within the same patient cohort.

Methods: This retrospective study included seven patients who underwent both EID-CT and PCD-CT for clinical indications. To ensure a valid comparison of the imaging technologies, images of the non-operated, contralateral temporal bone were evaluated.

View Article and Find Full Text PDF

Objective: To determine the impact of modifiable surgical factors on ossiculoplasty outcomes after controlling for ear environment risk.

Study Design: Multi-institutional retrospective review.

Setting: Six tertiary care centers from 2011 to 2019.

View Article and Find Full Text PDF

A mechanical lumped-element model of the human middle ear for bone conduction hearing.

Sci Rep

July 2025

Department of Communication Sciences and Disorders, Department of Bioengineering, Wayne State University, Detroit, MI, 48202, USA.

Bone conduction (BC) is an important modality of hearing. It enables us to differentiate conductive and sensorineural hearing loss, perceive sounds despite a disabled middle ear, and listen to conversation and music privately without blocking the ear canal. Yet the mechanism underlying BC is not fully understood mainly because the bone-conducted vibrations in the skull simultaneously stimulate the outer ear, the middle ear, and the cochlea.

View Article and Find Full Text PDF

Abnormalities in the ossicular chain, a key middle-ear component that is crucial for sound transmission, can lead to conductive hearing loss; reconstruction offers an effective treatment. Accurate preoperative ossicular-chain measurements are essential for creating prostheses; however, current methods rely on cadaver studies or manual measurements from 2-dimensional images, which are time-intensive and laborious and depend heavily on radiologist expertise. To improve efficiency, we aimed to develop a systematic approach for automated ossicular-chain segmentation and measurement using ultra-high-resolution computed tomography (U-HRCT).

View Article and Find Full Text PDF