98%
921
2 minutes
20
Abnormalities in the ossicular chain, a key middle-ear component that is crucial for sound transmission, can lead to conductive hearing loss; reconstruction offers an effective treatment. Accurate preoperative ossicular-chain measurements are essential for creating prostheses; however, current methods rely on cadaver studies or manual measurements from 2-dimensional images, which are time-intensive and laborious and depend heavily on radiologist expertise. To improve efficiency, we aimed to develop a systematic approach for automated ossicular-chain segmentation and measurement using ultra-high-resolution computed tomography (U-HRCT). One hundred forty patients (226 ears) with normal ear anatomy underwent U-HRCT. Twelve parameters were defined to measure ossicular-chain components. Automated measurements based on automated segmentation of 226 ear images were verified through manual measurements. We analyzed variations by ear side, sex, and age group. Stapes analysis was limited by segmentation accuracy. Complete segmentation of the malleus, incus, and stapes was achieved in 47 ears. Automated measurements of 8 parameters showed no significant differences compared to manual measurements in 47 cases. Significant sex-based differences emerged in all parameters except stapes footplate length, incudostapedial joint angle, and stapes volume ( = 0.205, = 0.560, and = 0.170, respectively). Notable side-specific differences were observed in female incus height and male malleus volume ( = 0.017 and = 0.037, respectively). No statistically significant differences were found in other parameters across different age groups, except for malleus and incus volumes ( = 0.015 and = 0.031). The proposed algorithm effectively automated ossicular-chain segmentation and measurement, establishing a normative range for ossicular parameters and providing a valuable reference for detecting abnormalities.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC12214297 | PMC |
http://dx.doi.org/10.34133/cbsystems.0305 | DOI Listing |
Abdom Radiol (NY)
September 2025
Research Centre for Optimal Health, School of Life Sciences, University of Westminster, London, UK.
Objectives: The escalating global incidence of obesity, cardiometabolic disease and sarcopenia necessitates reliable body composition measurement tools. MRI-based assessment is the gold standard, with utility in both clinical and drug trial settings. This study aims to validate a new automated volumetric MRI method by comparing with manual ground truth, prior volumetric measurements, and against a new method for semi-automated single-slice area measurements.
View Article and Find Full Text PDFIntroduction: Distraction methods such as virtual reality and cold vibration devices (Buzzy) are recommended during vascular access. Few studies focused on distraction during intramuscular injection.
Methods: This study evaluated the effect of distraction methods on procedure-related pain, fear, and anxiety during the intramuscular injection in children aged 5 to 12 years in the pediatric emergency department.
Nucleic Acids Res
September 2025
School of Biomedical and Pharmaceutical Sciences, Guangdong University of Technology, No. 100 Waihuanxi Road, Guangzhou 510006, China.
The 5' untranslated region (5'UTR) plays a crucial regulatory role in messenger RNA (mRNA), with modified 5'UTRs extensively utilized in vaccine production, gene therapy, etc. Nevertheless, manually optimizing 5'UTRs may encounter difficulties in balancing the effects of various cis-elements. Consequently, multiple 5'UTR libraries have been created, and machine learning models have been employed to analyze and predict translation efficiency (TE) and protein expression, providing insights into critical regulatory features.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
September 2025
Department of Orthopaedic Surgery, School of Medicine, Klinikum rechts der Isar, Technical University of Munich, Munich, Germany.
Purpose: Robotic arm-assisted total knee arthroplasty (raTKA) has demonstrated several advantages over manual TKA (mTKA), including enhanced early recovery. Reduced soft tissue trauma and avoidance of femoral intramedullary canal opening have been hypothesised to lower the systemic inflammatory response. However, findings from previous small-cohort studies have been inconsistent.
View Article and Find Full Text PDFKnee Surg Sports Traumatol Arthrosc
September 2025
Çankaya Hospital for Orthopedic Care, Ankara, Turkey.
Purpose: The aim of this study was to evaluate the impact of reduced spinopelvic mobility (SM) on knee flexion deformity (KFD) in patients undergoing total knee arthroplasty (TKA).
Methods: A retrospective analysis on 213 patients (271 knees) undergoing robotic-assisted primary TKA was conducted. Sagittal spinopelvic alignment (SSA) parameters-sacral slope (SS), pelvic incidence (PI), and pelvic tilt (PT)-were measured on lateral standing and sitting spinopelvic radiographs.