Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

: Precise implantation could play a crucial role in the technical success of transcatheter aortic valve replacement (TAVR) for some prostheses. The impact of an accidental implantation depth (ID) outside the recommended range has not been assessed for the ACURATE (NEO2). : Data from 1839 patients with severe native aortic stenosis treated with the NEO2 prosthesis were evaluated. We compared the results of prostheses implanted in an ID both inside and outside the recommendations. The outcome assessment followed the Valve Academic Research Consortium-3 criteria. : Patients were retrospectively divided into high (<3 mm; = 412), optimal (3-7 mm; = 1236), and low (>7 mm; = 169) implantations. Technical success (94.7% vs. 94.7% vs. 91.7%, = 0.296) and device success were high (90.1% vs. 89.3% vs. 84.6%, = 0.112) without differences between groups. Rates of relevant paravalvular regurgitation (PVL; >mild or VinV due to PVL) were comparable (1.2% vs. 1.8% vs. 1.2%, = 0.759). Even when hemodynamics were superior in the high-implantation group, with greater iEOA (1.01 cm/m vs. 0.95 cm/m vs. 0.92 cm/m, < 0.001), spontaneous embolization or after post-dilatation was more common. Low implantation was associated with a higher rate of associated pacemaker implantation (PPI) (6.1% vs. 8.8% vs. 14.8%, = 0.001). : Implantation with the ACURATE showed excellent hemodynamic results, including low gradients and a small number of relevant PVL, in line with a high technical success rate that was irrespective of the ID. A favorable outcome can also be achieved in accidental low or high positions. Low implantation was associated with a higher rate of associated pacemaker implantation. Deliberately high implantation should be avoided due to the risk of embolization.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11396697PMC
http://dx.doi.org/10.3390/jcm13175342DOI Listing

Publication Analysis

Top Keywords

low implantation
12
technical success
12
implantation
10
impact accidental
8
implantation depth
8
acurate neo2
8
implantation associated
8
associated higher
8
higher rate
8
rate associated
8

Similar Publications

Sodium orthovanadate (vanadate), a potent inhibitor of p53, has been shown in earlier work to alleviate total-body irradiation (TBI)-induced hematopoietic syndrome. However, as p53 plays a crucial role in normal spermatogenesis, its suppression may raise concerns about potential adverse effects on male reproductive function. In this study, we investigated whether vanadate exacerbates impairment of male fertility when administered for hematopoietic protection under TBI conditions.

View Article and Find Full Text PDF

Background: Transcatheter pulmonary valve implantation (TPVI) has emerged as a viable alternative to surgical pulmonary valve replacement for patients with congenital heart disease and right ventricular outflow tract dysfunction. However, its adoption in low-resource settings has been limited.

Case Summary: We report the first successful TPVI procedures in Tanzania.

View Article and Find Full Text PDF

Baroreflex activation therapy (BAT) improves functional status, quality of life, and exercise capacity in patients with heart failure with reduced ejection fraction; however, its direct effects on reversing adverse cardiac remodeling as assessed by improvements in cardiac structure, function, and coupling with the arterial system remain unclear. We present 2 cases of patients who initially presented with decompensated heart failure, and despite initial medical therapy and continued outpatient follow-up, were unable to tolerate full escalation of guideline-directed medical therapy. The patients remained symptomatic, with high biomarker levels, poor functional capacity, severe heart failure symptoms, and objectively had decreased stroke volume, low left ventricular ejection fraction, and high left ventricular mass.

View Article and Find Full Text PDF

Comparison of short- and long-term outcomes between transcatheter and surgical aortic valve replacement for bicuspid aortic valve stenosis: a systematic review and meta-analysis.

Int J Surg

September 2025

Department of Cardiovascular Surgery, The Affiliated Hospital, Southwest Medical University, Metabolic Vascular Diseases Key Laboratory of Sichuan Province, Key Laboratory of Cardiovascular Remodeling and Dysfunction, Luzhou, Sichuan, PR China.

Objective: This meta-analysis aimed to compare the perioperative safety and efficacy of transcatheter aortic valve replacement (TAVR) versus surgical aortic valve replacement (SAVR) in bicuspid aortic valve (BAV) stenosis.

Methods: We systematically analyzed studies from PubMed, Cochrane Library, Embase, and CNKI comparing TAVR and SAVR in BAV stenosis. Outcomes included postoperative mortality, complications, all-cause survival, and freedom from stroke.

View Article and Find Full Text PDF

Diatom-Inspired Scaffold for Infected Bone Defect Therapy: Achieving Stable Photothermal Properties and Coordinated Antibacterial-Osteogenic Functions.

Adv Mater

September 2025

State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Orthodontics, West China Hospital of Stomatology, Sichuan University, Chengdu, 610041, China.

Bone defect therapy frequently encounters bacterial infections and chronic inflammation, which impair bone regeneration and threaten implant stability. Iron oxide nanoparticles have attracted attention due to cost-effectiveness, biocompatibility, and metabolic safety. However, iron oxide nanoparticles still struggle to balance low-temperature efficient antibacterial activity, effective immunomodulation, and bone regeneration.

View Article and Find Full Text PDF