98%
921
2 minutes
20
Background: Diagnostic errors are a global patient safety challenge. Over 75% of diagnostic errors in ambulatory care result from breakdowns in patient-clinician communication. Encouraging patients to speak up and ask questions has been recommended as one strategy to mitigate these failures.
Objectives: The goal of the scoping review was to identify, summarize, and thematically map questions patients are recommended to ask during ambulatory encounters along the diagnostic process. This is the first step in a larger study to co-design a patient-facing question prompt list for patients to use throughout the diagnostic process.
Methods: Medline and Google Scholar were searched to identify question lists in the peer-reviewed literature. Organizational websites and a search engine were searched to identify question lists in the gray literature. Articles and resources were screened for eligibility and data were abstracted. Interrater reliability (K = 0.875) was achieved.
Results: A total of 5509 questions from 235 resources met inclusion criteria. Most questions ( n = 4243, 77.02%) were found in the gray literature. Question lists included an average of 23.44 questions. Questions were most commonly coded along the diagnostic process categories of treatment (2434 questions from 250 resources), communication of the diagnosis (1160 questions, 204 resources), and outcomes (766 questions, 172 resources).
Conclusions: Despite recommendations for patients to ask questions, most question prompt lists focus on later stages of the diagnostic process such as communication of the diagnosis, treatment, and outcomes. Further research is needed to identify and prioritize diagnostic-related questions from the patient perspective and to develop simple, usable guidance on question-asking to improve patient safety across the diagnostic continuum.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11803640 | PMC |
http://dx.doi.org/10.1097/PTS.0000000000001273 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFJ Med Case Rep
September 2025
Department of Anesthesiology, LMU University Hospital Munich LMU, Marchioninistrasse 15, 81377, Munich, Germany.
Background: The treatment of critically ill patients in intensive care units is becoming increasingly complex. For example, organ transplants are regularly carried out, the recipients are seriously ill, and the postoperative course can be complicated. This is why organ replacement and hemadsorption procedures are becoming increasingly important.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.