Energy resolution improvement in simplified alpha spectroscopy for radionuclidic purity tests on 225Ac production floors.

Radiat Prot Dosimetry

Department of Radiological Sciences, Graduate School of Human Health Sciences, Tokyo Metropolitan University, 7-2-10 Higashiogu, Arakawaku, Tokyo 116-8551, Japan.

Published: September 2024


Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

This study investigated the feasibility of a simplified method of alpha spectroscopy for radionuclidic purity tests at 225Ac production sites that eliminates the need for a vacuum chamber. The impact of enhancing the energy resolution using a collimator was evaluated through radiation transport simulations. The results showed that a full width at tenth maximum (FWTM) of <300 keV was achieved for alpha particles from 241Am, for which the main energy peak was 5.5 MeV. Experimental validation using an electrodeposition source containing 237Np, 241Am, and 244Cm confirmed an FWTM of 272 keV for both 241Am and 244Cm. These two peaks, with a difference of ~300 keV, were effectively separated. In response to the growing demand for targeted radioisotope therapy, this simplified alpha spectroscopy method offers the potential to detect 226Ra mixed with 225Ac generated by accelerators, given the alpha energy difference of ~700 keV.

Download full-text PDF

Source
http://dx.doi.org/10.1093/rpd/ncae185DOI Listing

Publication Analysis

Top Keywords

energy resolution
8
alpha spectroscopy
8
spectroscopy radionuclidic
8
radionuclidic purity
8
purity tests
8
tests 225ac
8
225ac production
8
resolution improvement
4
improvement simplified
4
simplified alpha
4

Similar Publications

Prolonging All-Optical Molecular Electron Spin Coherence in the Tissue Transparency Window.

J Am Chem Soc

September 2025

Division of Chemistry and Chemical Engineering, Arthur Amos Noyes Laboratory of Chemical Physics, California Institute of Technology, Pasadena, California 91125, United States.

Coherent electron spin states within paramagnetic molecules hold significant potential for microscopic quantum sensing. However, all-optical coherence measurements amenable to high spatial and temporal resolution under ambient conditions remain a significant challenge. Here we conduct room-temperature, picosecond time-resolved Faraday ellipticity/rotation (TRFE/R) measurements of the electron spin decoherence time in [IrBr].

View Article and Find Full Text PDF

This study develops an integrated X-ray absorption spectroscopy (XAS) photoemission electron microscopy (PEEM) platform on beamline BL09U at the Shanghai Synchrotron Radiation Facility (SSRF), enabling nanoscale characterization of complex materials through energy-resolved imaging and local-area XAS. By using the wide range of energy tunability, full access to different polarizations and PEEM's surface sensitivity, we have established a gap-monochromator control system under the EPICS framework to synchronize the elliptically polarized undulator (EPU) gap and monochromator energy dynamically, optimizing photon flux stability for absorption fine structure analysis. Combining X-ray magnetic circular dichroism (XMCD) and X-ray magnetic linear dichroism (XMLD) with PEEM and local-area XAS, this platform achieves concurrent mapping of electronic structures and magnetic domains in ferromagnetic nano-patterns, as demonstrated through our studies of NiFe Permalloy using this system.

View Article and Find Full Text PDF

Nano-laminography with a transmission X-ray microscope.

J Synchrotron Radiat

November 2025

Advanced Photon Source, Argonne National Laboratory, Lemont, IL 60439, USA.

Nano-laminography combines the penetrating power of hard X-rays with a tilted rotational geometry to deliver high-resolution, three-dimensional images of laterally extended, flat specimens that are otherwise incompatible with, or difficult to image using, conventional nano-tomography. In this work, we demonstrate a full-field, X-ray nano-laminography system implemented with the transmission X-ray microscope at beamline 32-ID of the upgraded Advanced Photon Source at Argonne National Laboratory, USA. By rotating the sample around an axis inclined by 20° to the incident beam, the technique minimizes the long optical path lengths that would otherwise generate excessive artifacts when planar samples are imaged edge-on.

View Article and Find Full Text PDF

Tender x-ray microfocus beamline employing a combined double crystal/multilayer grating monochromator.

Rev Sci Instrum

September 2025

Helmholtz-Zentrum Berlin für Materialien und Energie (HZB), Albert-Einstein-Str. 15, 12489 Berlin, Germany.

A new x-ray beamline at the Physikalisch-Technische Bundesanstalt laboratory at BESSY II provides monochromatized radiation in the energy range from 1 to 10 keV, with a typical focus size of 20 μm. It is not only optimized for high-resolution x-ray spectrometry and microscopy but also enables scattering experiments and radiometric measurements. The innovative monochromator consists of a plane grating monochromator module equipped with multilayer-coated blazed gratings for x-ray energies up to 4 keV and an integrated double-crystal monochromator module equipped with silicon (111) crystals for x-ray energies ranging from 2.

View Article and Find Full Text PDF

Biosensors for Detecting Small Rho GTPases: Monitoring Expression and Activation.

Bioessays

September 2025

MY Small G Protein Research Group, Bioprocess Technology Division, School of Industrial Technology, Universiti Sains Malaysia, Pulau Pinang, Malaysia.

Advanced biosensing technologies, such as Förster resonance energy transfer (FRET) and bioluminescence resonance energy transfer (BRET), have enabled real-time, high-resolution tracking of Rho GTPase activity, surpassing traditional methods like pull-down assays. However, current biosensors mainly detect the GTP-bound active state through effector interactions, without directly measuring Rho GTPase expression or identifying related biomarkers of abnormal activation. Small Rho GTPases are essential molecular switches that regulate key cellular processes such as cytoskeletal organization, cell movement, polarity, vesicle trafficking, and the cell cycle.

View Article and Find Full Text PDF