98%
921
2 minutes
20
Objective: This study assessed the potential of ultra-high resolution (UHR) and a 1024-matrix in photon-counting-detector CT (PCD-CT) for evaluating interstitial lung disease (ILD) in systemic sclerosis (SSc) patients.
Methods: Sixty-six SSc patients who underwent ILD-CT screening on a first-generation PCD-CT were retrospectively included. Scans were performed in UHR mode at 100 kVp with two different matrix sizes (512×512 and 1024x1024) and reconstructed at slice thicknesses of 1.5 and 0.2 mm. Image noise, subjective image quality, and ILD changes (ground glass opacities and reticulations) were evaluated on a 5-point Likert-scale by two independent readers.
Results: Interreader agreement for subjective image quality ranged from fair to almost perfect (Krippendorff-Alpha: 0.258-0.862). Overall image quality was highest for 1.5 mm/1024 matrix images [(reader 1: 4(4.4), reader 2: 5(4.5)]. Image sharpness was rated significantly better in 0.2 mm images (P < .001). Regarding ILD changes, 0.2 mm slice thickness outperformed 1.5 mm slice thickness significantly (P < .001), while there was no significant difference between the two matrix sizes. A 1024-matrix size demonstrated superiority in evaluating coarse reticulations compared to 512-matrix size.
Conclusion: UHR mode with a 0.2 mm slice thickness showed enhanced image sharpness and improved visibility of ILD changes compared to standard reconstructions. This has the potential to enable the early detection of subtle disease manifestations.
Advances In Knowledge: With the invention of PCD-CT different reconstruction algorithms need to be evaluated for specific pathologies. In our study ILD UHR mode with 0.2 mm slice thickness showed to be beneficial in the detection of parenchymal changes in patients with scleroderma.
Download full-text PDF |
Source |
---|---|
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11573125 | PMC |
http://dx.doi.org/10.1093/bjr/tqae170 | DOI Listing |
J Appl Clin Med Phys
September 2025
Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia, USA.
Purpose: Real‑time magnetic resonance-guided radiation therapy (MRgRT) integrates MRI with a linear accelerator (Linac) for gating and adaptive radiotherapy, which requires robust image‑quality assurance over a large field of view (FOV). Specialized phantoms capable of accommodating this extensive FOV are therefore essential. This study compares the performance of four commercial MRI phantoms on a 0.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Clinical Imaging Physics Group, Duke University Health System, Durham, North Carolina, USA.
Introduction: Medical physicists play a critical role in ensuring image quality and patient safety, but their routine evaluations are limited in scope and frequency compared to the breadth of clinical imaging practices. An electronic radiologist feedback system can augment medical physics oversight for quality improvement. This work presents a novel quality feedback system integrated into the Epic electronic medical record (EMR) at a university hospital system, designed to facilitate feedback from radiologists to medical physicists and technologist leaders.
View Article and Find Full Text PDFJ Appl Clin Med Phys
September 2025
Department of Radiation Oncology, University of Utah, Salt Lake City, Utah, USA.
Purpose: The development of on-board cone-beam computed tomography (CBCT) has led to improved target localization and evaluation of patient anatomical change throughout the course of radiation therapy. HyperSight, a newly developed on-board CBCT platform by Varian, has been shown to improve image quality and HU fidelity relative to conventional CBCT. The purpose of this study is to benchmark the dose calculation accuracy of Varian's HyperSight cone-beam computed tomography (CBCT) on the Halcyon platform relative to fan-beam CT-based dose calculations and to perform end-to-end testing of HyperSight CBCT-only based treatment planning.
View Article and Find Full Text PDFEur Radiol Exp
September 2025
Center for MR-Research, University Children's Hospital Zurich, University of Zurich, Zurich, Switzerland.
Background: Fetal MRI is increasingly used to investigate fetal lung pathologies, and super-resolution (SR) algorithms could be a powerful clinical tool for this assessment. Our goal was to investigate whether SR reconstructions result in an improved agreement in lung volume measurements determined by different raters, also known as inter-rater reliability.
Materials And Methods: In this single-center retrospective study, fetal lung volumes calculated from both SR reconstructions and the original images were analyzed.
Radiother Oncol
September 2025
Dept of Radiation Oncology, Centre Léon Bérard, Lyon, France. Electronic address:
Background And Purpose: To date, no consensus guidelines have been published that systematically guide delineation of primary and nodal Clinical Target Volumes (CTVs) in patients who require post-operative radiotherapy (PORT) for mucosal Head and Neck squamous cell carcinoma (HNSCC). As a result, significant individual, institutional and national variation exists in the way that CTVs are delineated in the post-operative setting, leading to considerable heterogeneity in radiotherapy treatment.
Methods: A multi-disciplinary group of experts convened by the European Society for Radiotherapy and Oncology (ESTRO) set-out principles for the multi-disciplinary management of oral cavity squamous cell carcinoma (OCSCC).