Background: The aim of the study was to analyze the real-world performance of MiniMed 780G (MM780G) Advanced Hybrid Closed Loop (AHCL) system users from Poland (PL) and compare it to the European region excluding Poland (EU-PL) in order to identify factors contributing to potential differences. The former achieved some of the best Time in Range (TIR) results globally using this technology.

Methods: CareLink Personal data uploaded by MM780G system users from August 2020 to December 2022 were analyzed.

Results: The Polish users (N=1304) on average reached to TIR of 79.1 ± 8.7 % (vs 73.0 ± 10.0 % for EU-PL, N=55659), a TBR<54 mg/dL of 0.6 ± 0.7 % (vs 0.4 ± 0.6 %) and a TBR<70 mg/dL of 2.9 ± 2.1 % (vs 2.1 ± 1.8 %). The adoption rate of optimal settings (i.e, GT=100 mg/dL, AIT=2hr) in PL was high (19.7 % vs 6.3 %), and filtering on optimal setting users led to less pronounced differences in glycemic control between PL and EU-PL. A univariable analysis with post-AHCL TIR showed that geography itself (PL vs EU-PL) is not a significant contributor to a high post-AHCL TIR (p = 0.15), and that much of the Polish post-AHCL TIR can be explained by the high pre-AHCL TIR.

Conclusion: The Polish MM780G users achieved better glycemic control than the general European population (excluding Poland). This is largely attributable to the adoption of optimal settings in Poland and the already high glycemic outcomes at system start. As these characteristics can be implemented elsewhere, we believe this outstanding result can be obtained in other countries as well.

Download full-text PDF

Source
http://dx.doi.org/10.1016/j.diabres.2024.111832DOI Listing

Publication Analysis

Top Keywords

advanced hybrid
8
system users
8
excellence management
4
management advanced
4
hybrid closed-loop
4
closed-loop systems
4
systems lessons
4
lessons polish
4
polish cohort
4
cohort background
4

Similar Publications

Engineering functional exosomes represents a cutting-edge approach in biomedicine, holding the promise to transform targeted therapy. However, challenges such as achieving consistent modification and scalability have limited their wider adoption. Herein, we introduce a universal and effective strategy for engineering multifunctional exosomes through cell fusion.

View Article and Find Full Text PDF

Background: Men who have sex with men (MSM) and transgender women (TGW) are at elevated mpox risk; vaccination can greatly reduce that risk. We assessed mpox awareness and vaccine acceptability among MSM and TGW.

Methods: In 2022, hybrid-mode (offline/online) surveys were administered among 250 MSM and 251 TGW in Chennai, India.

View Article and Find Full Text PDF

UVA/B-Selective Skin-Inspired Nociceptors Based on Green Double Perovskite QDs-Sensitized 2D Semiconductor toward Reliable Human Somatosensory System Simulation.

J Phys Chem Lett

September 2025

Tianjin Key Laboratory of Film Electronic and Communication Devices, School of Integrated Circuit Science and Engineering, Tianjin University of Technology, Tianjin 300384, China.

Achieving UVA/B-selective, skin-inspired nociceptors with perception and blockade functions at the single-unit device level remains challenging. This is because the device necessitates distinct components for every performance metric, thereby leading to complex preparation processes and restricted performance, as well as the absence of deep UV (UVB and below)-selective semiconductors. Here, to address this, we develop a structure-simplification skin-inspired nociceptor using a reverse type-II CuAgSbI/MoS heterostructure.

View Article and Find Full Text PDF

Surface-Driven Electron Localization and Defect Heterogeneity in Ceria.

J Am Chem Soc

September 2025

Kathleen Lonsdale Materials Chemistry, Department of Chemistry, University College London, London WC1H 0AJ, U.K.

The exceptional performance of ceria (CeO) in catalysis and energy conversion is fundamentally governed by its defect chemistry, particularly oxygen vacancies. The formation of each oxygen vacancy (V) is assumed to be compensated by two localized electrons on cations (Ce). Here, we show by combining theory with experiment that while this 1 V: 2Ce ratio accounts for the global charge compensation, it does not apply at the local scale, particularly in nanoparticles.

View Article and Find Full Text PDF

Management of diabetes mellitus in hemodialysis is highly complex due to increased glycemic variability and hypoglycemic risk. The use of technologies applied to diabetes has been shown to improve glycemic control, however data in dialysis patients are limited. To describe the efficacy and safety of the minimed 780G AHCL system in a stable hemodialysis patient and during hospitalization in the Intensive Care Unit (ICU).

View Article and Find Full Text PDF