Category Ranking

98%

Total Visits

921

Avg Visit Duration

2 minutes

Citations

20

Article Abstract

Ionic conductive hydrogel has recently garnered significant research attention due to its potential applications in the field of wearable and flexible electronics. Nonetheless, the integration of multifunctional and synergistic advantages, including reliable electronic properties, high swelling capacity, exceptional mechanical characteristics, and self-adhesive properties, presents an ongoing challenge. In this study, we have developed an ionic conductive hydrogel through the co-polymerization of 4-Acryloylmorpholine (ACMO) and sodium acrylate using UV curing technology. The hydrogel exhibits excellent mechanical properties, high conductivity, superior swelling capacity, and remarkable self-adhesive attributes. The hydrogel serves as a highly sensitive strain sensor, enabling precise monitoring of both substantial and subtle human motions. Furthermore, the hydrogel demonstrates the capability to adhere to human skin, functioning as a human-machine interface for the detection of physiological signals, including electromyogram (EMG) signals, with low interfacial impedance. This work is anticipated to yield a new class of stretchable and conductive materials with diverse potential applications, ranging from flexible sensors and wearable bio-electronics to contributions in the field of artificial intelligence.

Download full-text PDF

Source
http://www.ncbi.nlm.nih.gov/pmc/articles/PMC11332826PMC
http://dx.doi.org/10.1016/j.heliyon.2024.e35187DOI Listing

Publication Analysis

Top Keywords

wearable flexible
8
flexible sensors
8
ionic conductive
8
conductive hydrogel
8
potential applications
8
properties high
8
swelling capacity
8
hydrogel
6
high stretchable
4
stretchable self-adhesive
4

Similar Publications

Soft wearable sensors offer promising potential for advanced diagnostics, therapeutics, and human-machine interfaces. Unlike conventional devices that are bulky and rigid, often compromising skin integrity, comfort, and user compliance, soft wearable sensors are flexible, conformable, and better suited to the dynamic skin surface. This improved mechanical integration enhances signal fidelity and device performance, while also enabling safer, more comfortable, and continuous physiological monitoring in real-world environments.

View Article and Find Full Text PDF

Recent advances in eutectogels: Preparation, properties and applications.

Adv Colloid Interface Sci

September 2025

Key Laboratory of Colloid and Interface Chemistry (Ministry of Education), Shandong University, Jinan 250100, PR China. Electronic address:

Multiple stretchable gels with conductivity have been thoroughly prepared in diverse solvents historically to modulate their superlative properties in a multitude of applications, such as soft robotics, wearable devices, and e-skins. Eutectogels are considered as an emerging class of gels that combine the best features of both hydrogels and organogels, including environmental friendliness, thermal stability and customizable nature. Eutectogels, composed of deep eutectic solvents (DES) immobilized within different matrices, not only inherit the merits of DES, but also show some additional properties derived from the special structure and compositions, which are conducive to development potential.

View Article and Find Full Text PDF

Multifunctional triple-network ionic hydrogel sensors engineered by Al/Zn bimetallic salt solution: From cellulose solvent to conductive network architecture.

J Colloid Interface Sci

September 2025

Research Center of Nano Science and Technology, College of Sciences, Shanghai University, Shanghai 200444, PR China. Electronic address:

Ionic conductive hydrogels show promise for flexible sensors in wearables and e-skins, but balancing mechanical strength with high conductivity remains challenging. Herein, a triple-network ionic conductive hydrogel based on poly(acrylic acid) (PAA) was developed, synergistically reinforced by dissolved cellulose (dCel) and aramid nanofibers (ANF), with Al/Zn bimetallic ions serving as the conductive medium. Intriguingly, dCel was in-situ generated using the concentrated Al/Zn bimetallic salt solutions as the cellulose solvent, following the complete dissolution of the pulp fibers driven by the intensive ionic hydration of Al/Zn ions.

View Article and Find Full Text PDF

Flexible, multifunctional sensor based on core-sheath sensing medium for humidity sensing and heat-resistant pressure.

Biosens Bioelectron

September 2025

School of Resources, Environment and Materials, Guangxi University, Nanning, 530004, Guangxi, China; Guangxi Key Laboratory of Processing for Non-ferrous Metals and Featured Materials, Guangxi University, Nanning, 530004, China. Electronic address:

The practical implementation of wearable sensing devices for human health monitoring requires significant advancements in lightweight design and multifunctional integration. Fiber-shaped sensors have attracted considerable research attention due to their ability to maintain exceptional sensitivity and measurement accuracy under various mechanical deformations, including bending, stretching, and torsion. Nevertheless, the functional integration remains constrained, particularly as evidenced by sensitivity degradation and device failure under extreme high-temperature conditions, which severely hinders their practical applicability for real-time health monitoring applications in complex environmental scenarios.

View Article and Find Full Text PDF

Ultra-High Zinc Utilization Enabled by MXene Anode for Flexible Dual-Plating Zn-Br Microbatteries.

J Phys Chem Lett

September 2025

College of Materials Science and Engineering, Sichuan University, No. 24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China.

Aqueous zinc-ion microbatteries exhibit promising prospects for wearable devices due to their high safety and cost-effectiveness but face challenges such as low energy density and short cycle life. To address these challenges, a dual-plating flexible Zn-Br microbattery was developed using freestanding MXene films as a zinc metal free anode. The MXene anode retains no redundant Zn, as Zn from the electrolyte undergoes deposition/stripping reactions on its substrate, thereby eliminating the necessity for excess zinc.

View Article and Find Full Text PDF